13.07.2015 Views

The First Solar Water Heater with an integrated - Thermal Products Inc

The First Solar Water Heater with an integrated - Thermal Products Inc

The First Solar Water Heater with an integrated - Thermal Products Inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Venting OptionsSIDEWALL VENTING WITH TEE (INTAKE) ANDSIDEWALL VENTING COUPLING WITH EXHAUST TEE (INTAKE) ANDCOUPLING EXHAUST12"MIN.1"MIN.EXTERIOR WALLModel<strong>Solar</strong> Recovery CapacitiesGallonCapacityInput BTU/hrHeated <strong>Water</strong>Volume ofGas Back-Upat <strong>First</strong> DrawRecovery Of Back Upin Minutes65˚ Rise90˚ RisePH199-119S 119 66,000–199000 61 GAL 10 MIN 14 MINPH199-80S 80 66,000–199000 41 GAL 7 MIN 10 MINPH130-119S 119 44,000–130000 61 GAL 16 MIN 21 MINPH130-80S 80 44,000–130000 41 GAL 11 MIN 15 MINEXHAUSTINTAKESUPPORT BRACKETSMUST BE USED ONALL HORIZONTALAND VERTICAL PIPING1"MIN.CONCENTRIC VENT KITPART# KGAVT0501CVT - 2"KGAVT0601CVT - 3"EXTERIOR WALLLEFT SIDE VIEWLEFT SIDE VIEWIMPORTANT:INTAKE LEG MUST BE FACING UPINTAKEEXHAUSTLP-201-CSIDEWALL VENTING WITH TEE (INTAKE) ANDSIDEWALL VENTING WITH TEE (INTAKE) ANDCOUPLING (EXHAUST)SUPPORT BRACKETSMUST BE USED ONALL HORIZONTALAND VERTICAL PIPINGLP-201-BSpecification<strong>The</strong> Phoenix <strong>Water</strong> <strong>Heater</strong> shall bem<strong>an</strong>ufactured by Heat Tr<strong>an</strong>sfer <strong>Products</strong>,<strong>Inc</strong>. <strong>with</strong> identification of model numberPH________. <strong>The</strong> water heater shall bea sealed combustion system, taking onlyoutside air for combustion <strong>an</strong>d exhaustingthe flue gas <strong>with</strong> PVC Schedule 40 or 80PVC, or CPVC solid core pipe. <strong>The</strong> heateras well as all related intake air <strong>an</strong>dexhaust intake air <strong>an</strong>d exhaust gas pipingshall be approved for zero clear<strong>an</strong>ce to<strong>an</strong>y combustible surface. <strong>The</strong> units totalcombined equivalent venting length,including fitting allow<strong>an</strong>ces for boththe intake air <strong>an</strong>d exhaust gas shall notexceed 85’ (in the units native size asm<strong>an</strong>ufactured <strong>an</strong>d stated on the unitmodel product data sheet) in 2”, or 3” pipeor 125’ for the next size up of 3” or 4” fromthe heaters location.<strong>The</strong> solar heaters t<strong>an</strong>k shall be constructedof 316L stainless steel. <strong>The</strong> primary gasfired condensing heat exch<strong>an</strong>ger shall beconstructed of 90/10 cupronickel. <strong>The</strong>secondary gas fired heat exch<strong>an</strong>ger shallbe constructed of 800H stainless steel <strong>an</strong>d90/10 cupronickel. <strong>The</strong> t<strong>an</strong>k insulation shallbe water blown foam 2” thick in the sidewall <strong>with</strong> a rating of R14.2 <strong>an</strong>d 3” thick inthe top <strong>with</strong> a rating of R21.3. Insulationshall be enclosed in a plastic jacket on thesides as well as the top <strong>an</strong>d bottom. Allcomponents shall be located on the frontof the heater for easy access <strong>an</strong>dserviceability. All related hardware shallbe constructed of stainless steel studs<strong>with</strong> brass nuts for serviceability. All waterconnection nipples shall be constructed ofstainless steel <strong>an</strong>d be attached to the sideof the t<strong>an</strong>k. <strong>The</strong> top <strong>an</strong>d bottom of the t<strong>an</strong>kshall be smooth <strong>with</strong> no pipe tappings onthe top or legs on the bottom.<strong>Solar</strong> models shall have <strong>an</strong> additionalinternal heat exch<strong>an</strong>ger on the bottom ofthe t<strong>an</strong>k to connect to a solar system.<strong>The</strong> heaters shall be UL/ULC listed <strong>an</strong>dwill exceed the minimum efficiencyrequirements of ASHRAE 90.1b -1992. Allheaters shall be approved in accord<strong>an</strong>ce<strong>with</strong> ANSI Z 21.10.3. All heaters will besupplied <strong>with</strong> a factory installed ASMErated temperature <strong>an</strong>d pressure reliefvalve. All heaters shall be supplied <strong>with</strong>a factory installed low water cutoff, <strong>an</strong>dupper hot water sensor, <strong>an</strong>d lower coldwater sensor. All heaters shall be furnished<strong>with</strong> a factory installed condensate trapassembly ready for easy connection to afield supplied condensate drain.<strong>The</strong> heater shall have <strong>an</strong> <strong>integrated</strong> digitalcontroller device <strong>with</strong> integral diagnostics,LED fault <strong>an</strong>d temperature settingsfor establishing set point, temperaturedifferential. Ignition shall be <strong>with</strong> directspark <strong>with</strong> ignition taking place at a pre-setignition speed for the burner blower. <strong>The</strong>control shall utilize <strong>an</strong> algorithm to fullyadjust the burner modulating firing ratewhile maintaining the desired temperature.<strong>The</strong> pre-mix stainless steel burner uses a120 volt motor <strong>with</strong> pulse wave modulationcontrol to ch<strong>an</strong>ge the f<strong>an</strong> speed, thus thecombustion air volume of fuel <strong>an</strong>d airthrough the burner to establish <strong>an</strong> infiniteBTU input r<strong>an</strong>ge equal to the water heatingset point requirement. <strong>The</strong> digital LEDcontrol display shall provide me<strong>an</strong>s, viapush buttons, for adjustments of operatingtemperatures, differential adjustment, ECOreset, service mode, <strong>an</strong>d real time statusmode. In addition there shall be provided acomputer connection via laptop computerfor perpetual history including all faultcodes, <strong>an</strong>d hours of operation above 50%of input, below 50% of input as well as realtime status reporting of all operations. <strong>The</strong>burner assembly shall be mounted so as tobe easily removed as <strong>an</strong> integral unit foreasy serviceability.<strong>The</strong> heater shall be in compli<strong>an</strong>ce <strong>with</strong>the NOx Emissions limit as set forth inSCAQMD Rule 1146.2 – 1998.<strong>The</strong> heater shall be factory assembled; testfired for correct BTU input <strong>an</strong>d adjusted forproper combustion parameters. Completeoperating <strong>an</strong>d installation instructionsshall be furnished <strong>with</strong> every heater aspackaged by the m<strong>an</strong>ufacturer <strong>with</strong> theheater for shipping.Copyright 2008www.htproducts.com LP-201 Rev. 2/1/08

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!