13.07.2015 Views

GEA CAIRfricostar - CS Klimateknik

GEA CAIRfricostar - CS Klimateknik

GEA CAIRfricostar - CS Klimateknik

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Dehumidifier with Air Mixing FunctionType CWP<strong>GEA</strong> <strong>CAIRfricostar</strong>Alternative fan unit:<strong>GEA</strong> „OPTIVENT“ high performance fan impellers– Surface coated one side suction with backward curved blades that are directly connectedto motor shaft; performance optimized three-phase motor, B3 model type,protection type IP55, insulation class F adjusted for operation with a frequency converter.Fan and motor unit including coated intake nozzle mounted on bucklingresistant and coated base construction, motor and fan have sound attenuated bearings.– Continuous measurement of pressure effects– Statically and dynamically balanced according to DIN ISO 1940, part 1, G2,5). Continuousmonitoring of operation using DDC. Frequency converter for each motorinstalled in or mounted on the unit, control via <strong>GEA</strong> DDC with a separate analoguesignal for both motors. Frequency converters are adjusted and set for both motors.Limit values for motor current and fan speed are set by the programme– Resonance frequency band/fade out set by factory– Automatic energy optimization for optimal energy use and efficiency rate– Multiple motor operation is possible– Voltage intermediate circuit converter without reduction of capacity– Continuous speed control– Operating hours counter– Min. and max. speed limitation, automatic ramp curve function UP/DOWN– Automatic motor adjustment– Motor tracing switch– DC break– Variable clock frequency– Motor protection– Short circuit and short circuit to earth safe– Under and over current protection– Phase fault monitoring– Motor coils for reducing speed of voltage rise du/dt (delta voltage/delta time)– Numerical display for queries and entering of different indicators on operating status:control setpoint, motor frequency, actual value and setpoint, motor current,motor torque and capacity, intermediate circuit voltage, thermal motor load, thermalfrequency converter load, control and programmable display with copy function,production according to ISO 9001, CE Label, net and main shaft protection accordingto VDE 0160, radio interference shielding, codes and regulations on electromagneticcompatibility conform with EN 55011 Kl.B-1; EN 50082-2, electricinsulation of control and power components according to VDE 0106/0160 (The useof earth leakage circuit breaker / fuse with frequency converters NOT possible!),volume flow measuring device via ring measuring line and pressure measuringpoint in fan. Calculation and evaluation of volume flow via the <strong>GEA</strong> DDC. The settingsfor entire unit are done at the factory. Continuous safety monitoring via safetychain in the unit. Display and settings via <strong>GEA</strong> DDC.Air damper system: – Dampers with sealing lips, leakage volume flow 20 m3/h m2 (dp=100 Pa), for circulatingair/bypass, for fresh and exhaust air. Circulating and fresh air rate 0-100%– Coated AlMg3 damper blades with flow efficient profile, operate in opposite directions.Driven by double sided, anti-static plastic gears PA6 as fiberglass reinforcedmodel (resistant to chemicals) including special actuator for each damper– Control of the individual actuators using continuous DDC signalsFilter for fresh andexhaust air:– Filter units conform with VDI 6022– Including bag filter as of DIN/EN 779, synthetic fiber filter medium– All filters are fitted with a differential pressure switch for filter monitoring via the DDC38 PR-2008-0327-GB • Subject to modifications • Status 09/2008

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!