13.07.2015 Views

Phthalates and Nonylphenols in Roskilde Fjord

Phthalates and Nonylphenols in Roskilde Fjord

Phthalates and Nonylphenols in Roskilde Fjord

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

• In 1969 <strong>in</strong> connection with work on the <strong>Roskilde</strong> harbour, the sedimentwas dumped on the site marked ∇ on the map <strong>in</strong> Figure 2. Thishas s<strong>in</strong>ce then been a source of leach<strong>in</strong>g to the <strong>Fjord</strong> water. The loadhas decreased with time <strong>and</strong> is today estimated to be negligible comparedto the WWTP discharge.• The flux of sal<strong>in</strong>e water from the sea to the <strong>Fjord</strong> is 3 to 4 times largerthan the freshwater flux to the <strong>Fjord</strong> (Hedal et al, 1999). In Table 24the three water exchange rates are stated.6.3 Model parametersThe follow<strong>in</strong>g model parameters are required <strong>in</strong> the models.Calculated <strong>and</strong> measured state variablesC w : Concentration of dissolved substance <strong>in</strong> water phase [mg ⋅ litre -1 ].C s : Concentration of dissolved substance <strong>in</strong> sediment phase [ng ⋅ g -1 ].Measured model <strong>in</strong>putsX w : Concentration of suspended particulate matter <strong>in</strong> water phase= 10 ⋅ 10 -6 kg DM ⋅ (litre total) -1X s : Concentration of dry matter <strong>in</strong> sediment= 1.06 kg DM ⋅ (litre total) -1θ s : Water fraction <strong>in</strong> sediment= 0.55 litre water ⋅ (litre total) -1Q WWTP :Discharge flow from WWTP= 492 ± 356 m 3 ⋅ hour -1C WWTP : Concentration of dissolved DEHP <strong>in</strong> WWTP discharge= 0.7 µg DEHP ⋅ litre -1R WWTP : Retention factor for WWTP discharge= 1.05C tot,dep : Atmospheric bulk deposition= 7.29 ⋅ 10 -15 kg DEHP ⋅ (m 2 ⋅ sec) -1C tot,f : Concentration of mean total substance <strong>in</strong> freshwater from streams= 0.2 µg DEHP ⋅ litre -1Calibration parametersK d :Distribution coefficient between water <strong>and</strong> organic matter <strong>in</strong> wateror sediment [litre water ⋅ (kg DM) -1 ].k 1N : Aerobic pseudo 1 st order removal rate [sec -1 ].k 1D : Anaerobic pseudo 1 st order removal rate [sec -1 ].S: Annual sediment accumulation rate [mm ⋅ year -1 ].Estimated model <strong>in</strong>putsParameters <strong>in</strong> Table 24.D wx : Horizontal dispersion coefficient <strong>in</strong> narrow part of <strong>Fjord</strong>= 54 m 2 ⋅ sec -1D sz : Molecular diffusion coefficient <strong>in</strong> sediment= 2 ⋅ 10 -10 m 2 ⋅ sec -1The hydraulic <strong>and</strong> geographical key data for <strong>Roskilde</strong> <strong>Fjord</strong> are shown <strong>in</strong>Table 24.65

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!