INFORMATION:For a leakage-free tapping of pressurised pipings, we recommendthe tapping unit of the company of Hütz + Baumgarten, Remscheid(www.huetz-baumgarten.de). Please ask our Application EngineeringDepartment.13. Transition Fittings13.1 <strong>Assembly</strong>WARNING!When removing the PE protectionlid, please ensure that the wire isnot damaged.The general installation instructionsfor the FRIALEN ® SafetyFittings (see Chapters 4.1 - 4.9)are to be observed.13.2 Transition Fittings with steelpipeFig. 30WARNING!In addition, the following items are to be considered:- A shortening of the steel pipe is impermissible because the heat introductionduring fusion has a negative effect on the sealing system.- Fusion of the steel side only by arc welding.- When fusing the steel end it has to be prevented that fusion vapour andfusion beads get into or to the FRIALEN ® Coupler with integrated heatingcoil.27