14. Repair Sleeves forpipes d 32 – d 63,SDR 11WaterThe sleeve (Fig. 34) prevents thesubsequent flow of residual waterinto the fusion zone during repair orconnection to house service pipingsfor water (Fig. 35).14.1 <strong>Assembly</strong>For a repair of the damaged waterpipe, a fitting piece with two slideover couplers FRIALEN ® UB andtwo repair sleeves FRIALEN ® RW isprepared.The water pipe has to be bendcorrespondingly to install the fittingpiece. Having positioned the slideover couplers, fusion is made analogueto Items 4.2-4.9.Fig. 34Fig. 3529