21.07.2015 Views

saris - Scintrex

saris - Scintrex

saris - Scintrex

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ELECTRICAL METHODSSARISMulti-Electrode Array Resistivity System


SARIS SPECIFICATIONSThe SARIS has been successfully used for many years as a mineral and oil & gas exploration tool. Resistivity is nowroutinely used for a wide variety of applications whether your application is groundwater, environmental, archaeologyor resource exploration.Hydrogeological applications, such as groundwater exploration, use the resistivity technique as the main explorationtool.Migration of ground water pollution is easily monitored and measured using SARIS. Plumes of contaminant leachingout of a landfill site, for example, are of great concern.Geotechnical, Engineering and Archaeological applications have also been addressed using the resistivity technique.SARIS simply allows you to do this better.Output Power:up to 100 WOutput Current:up to 1.0 AOutput Current Precision: +/- 1.25%Maximum Output Voltage: up to 500 VInput Impedance:11 MΩInput Voltage Range:up to 40 VInput Voltage Precision: +/- 1%Input Resolution: 0.6 µVDynamic Range:156 dBNoise Rejection:98 dB power line rejectionSP Compensation:0 to 1 V, automaticDV/I Precision: 1%Cycle Time:5 or 6 Hz1,2,4,8 secondsOverall Accuracy: +/- 1%Operating Temperature: -20°C to +55°CEnvironmental:IP64 environmental protection(waterproof)Power Supply:Rechargeable dry lead acid batteriesMeasuring Capacity:>10,000 (depends on load)Memory Capacity:>10,000 readingsInterface:USB data outputDimensions and Weights:ISO 9001:2000 registered company.(Excluding connectors)Basic System with battery: 226 x 190 x 177 mm (8.9” x 7.5” x 7”)Multi-Electrode Interface: 336 x 190 x 60 mm (13.22” x 7.5” x 2.36”)Basic system with battery:Battery only:Multi-Electrode Interface:8.9 kg (19.62 lbs.)6.4 kg (14 lbs.)1.4 kg (3 lbs.)CABLE SYSTEMUsing the SARIS Multi-ElectrodeInterface allows the use of“Intelligent Electrode” imagingcable systems. Each standardimaging cable has 5 takeouts at5m defined spacing for eachtakeout. Each cable system comeswith the appropriate number ofstainless steel electrodes andconnector clips. SARIS imagingcable systems provide the uniquefeature of being able to expandyour array by simply connectingadditional cables to the end of oneanother.All specifications are subject to change without notice. Specification Sheet Part Number: 735705 Revision 0CANADA<strong>Scintrex</strong>222 Snidercroft RoadConcord, Ontario L4K 2K1Telephone: +1 905 669 2280Fax: +1 905 669 6403e-mail: scintrex@scintrexltd.comWebsite: www.scintrex.comUSAMicro-g LaCoste1401 Horizon AvenueLafayette, CO 80026Telephone: +1 303 828 3499Fax: +1 303 828 3288e-mail: info@microglacoste.comWebsite: www.microglacoste.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!