Mobrey ultrasonic liquid level detection systems ATEX

Mobrey ultrasonic liquid level detection systems ATEX

Mobrey ultrasonic liquid level detection systems ATEX

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Electropulse control room electronics75mm112mm150mmElectropulse MEP3L Stand alonereadout unitWall or DIN rail mountedpolycarbonate single readout unit.Front panel LED indicators for <strong>liquid</strong><strong>level</strong> sensor, normal, alarm and faultcondition. Single relay outputs deenergisedfor alarm and fault.130mm30mmElectropulse MEP3R Rack mountedreadout cardSingle point readout card for usein a 19" rack system type MEP3B.Front panel LED indicators for<strong>liquid</strong> <strong>level</strong> sensor alarm and faultconditions. Independent alarm relayand fault relay.483mm210mm134mm265 mm1. Electropulse MEP3LStand alone readout unitRelay outputEnergised for "Normal" condition.De-energised for "Alarm" conditionafter preset delay. De-energisedfor "Fault" condition. Double polechangeover contacts.Rating:500VA PF 0.4 on MEP3L at 250VrmsAmbient temperature: -10°C to+65°CPower Consumption: 7VACable Entry: Via cutouts in the basethrough rubber grommets to terminalstripProtection: IP202. Electropulse MEP3R Rackmounted readout cardAlarm relay outputEnergised for "Normal" conditionafter preset delay.De-energised for "Fault"condition.(i) DPCO option, relay contact ratingfor MEP3R is 45VA at 250V rms.(ii) SPCO option, relay contactrating for MEP3R is 500Va at 0.4PFFault relay outputDe-energised for "Normal" condition.Energised for "Fault" condition.SPCO relay, contact rating forMEP3R is 500VA at 0.4PFAmbient temperature: -10°C to +55°CPower consumption: 6VAInstallation consideration:Allow at least a 50mm gapbetween each rack on multiple rackinstallations to allow air circulation.On installation of 4 or more racks,the fitting of a cabinet air circulatingfan is recommended.Ordering information on page 17Common specificationFunctionProvides power supply to sensor headamplifier and detects sensor state.Operates output relays and frontpanel LED indicators, providing delayadjustments and control test system.monitors plant wiring integrity.Design concept - fail safetyThe readout unit electronic designfeature fail to safety (alarmcondition) for any anticipatedelectronic, mechanical or wiringfailure.Hazardous area approvalUnits are available approved to <strong>ATEX</strong>II (1) G [EExia] IIC. This allowssuitably specified plant cabling tobe led directly in the hazardous areaand connected to the Electropulsehead amplifiers.SpecificationInput:220/240V AC + 10% 50/60 Hz110/120V AC + 10% 50/60 HzFront panel LED indicatorsGreen - Normal conditionRed - Alarm conditionAmber - Fault conditionNOTE:Fault condition always triggers alarm.Normal condition is gap sensor wet,or Hi-Sens dry.Delay:Alarm to normal: less than 100msecNormal to alarm: screwdriveradjustable from 1 to 10s.Normal to fault: less than 100 msec.Test:Front panel push to test switchsimulates alarm or fault conditionsand triggers alarm relay (also faultrelay on MEP3R).Output:Supply to Electropulse head amplifier(12V dc) is fully floating (galvanicallyisolated). The output is short circuitproof for short periods only.Electropulse MEP3B Rack forElectropulse cardsRack system housing up to 14MEP3R cards15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!