30.07.2015 Views

Mobrey ultrasonic liquid level detection systems ATEX

Mobrey ultrasonic liquid level detection systems ATEX

Mobrey ultrasonic liquid level detection systems ATEX

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

System descriptionA <strong>Mobrey</strong> <strong>ultrasonic</strong> <strong>liquid</strong> <strong>level</strong>control comprises:• A tank mounted sensor containingtransmitter and receiver crystals• An RF sensor drive and detectorelectronic circuit, which may beintegral with the sensor or mountedadjacent to the sensor dependingupon vessel conditions or accessconsiderations.• A control unit mounted remotely tomonitor the sensor state and providethe required switching functionChoice of sensor<strong>Mobrey</strong> gap sensors<strong>Mobrey</strong> gap sensors energise a relayoutput when there is a <strong>liquid</strong> presentbetween the transmitter and receivercrystals of the sensor. In this way,absense of <strong>liquid</strong>, power failure ordamage to plant cabling will result inan alarm condition.Gap sensors are fail-safe low <strong>level</strong>.Typical applications• Pump protection• Vessel empty protection• Foam/froth <strong>detection</strong>• Pump control<strong>Mobrey</strong> Hi-sens sensors<strong>Mobrey</strong> Hi-sens sensors operate ina reverse manner. The transmitterand receiver crystals communicatearound the wall of the sensor whenit is dry. Presence of <strong>liquid</strong> aroundthe sensor damps out the 'ringing' ofthe sensor and an alarm condition isthen signalled.<strong>Mobrey</strong> Hi-sens is therefore failsafehigh <strong>level</strong> and will signal an alarmcondition on presence of <strong>liquid</strong>,power failure or damage to plantcabling.Typical applications• High <strong>level</strong> alarm• Overfill prevention• Leak <strong>detection</strong>Ultrasonic sensor operation can beadversely affected by the presenseof excessive aeration, solids orfoam in the <strong>liquid</strong>. If you have anapplication query contact <strong>Mobrey</strong> forexpert advice on the selection of asuitable <strong>liquid</strong> <strong>level</strong> <strong>detection</strong> systemSensors may be mounted in anyposition to signal <strong>liquid</strong> presence.Sensor with adjacent amplifierSensorwith headamplifier<strong>Mobrey</strong> gap sensor: General purpose failsafe low <strong>level</strong>b) Sensor in <strong>liquid</strong>The <strong>ultrasonic</strong> signalreaches receiver crystalTransmittercrystala) Sensor in airThe <strong>ultrasonic</strong> signal willnot reach receiver crystalReceivercrystalControl unitControl unit<strong>Mobrey</strong> hi-sens sensor (Models HL & HD): Fail safe high <strong>level</strong>a) Sensor in airThe <strong>ultrasonic</strong> signalreaches receiver crystalb) Sensor in <strong>liquid</strong>The <strong>ultrasonic</strong> signal is lost intothe <strong>liquid</strong> and does not reachreceiver crystalRelay output isenergised-NORMALSTATERelay output isde-energised-ALARM STATEControl unitControl unitControl roomelectronicsRelay outputis energised-NORMALSTATESignal is receivedRelay output isde-energised-ALARM STATENo signal is received

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!