3. REPLACING A DAMAGED ELECTRIC COMPONENTPlease note, that an authorized person may only replace the damaged electric compon<strong>en</strong>t.WARNING:Before changing the damaged compon<strong>en</strong>t make sure that the circuit is reliably switched off!A new motor, defrost heater or thermostat:• Op<strong>en</strong> the fan plate• Op<strong>en</strong> the cover plate of the junction box• Release the cables of the damaged compon<strong>en</strong>t• Replace the damaged compon<strong>en</strong>t• Connect the new compon<strong>en</strong>t• Check the earthing• Close the cover plate of the junction box• Close the fan plate• Make a test-runFig. 7
Declaration by the manufacturer of the compon<strong>en</strong>tincorporated to the machinery (Directive 2006/42/EC, Annex II,sub.B)ALFA LAVAL VANTAA OYAnsatie 3, FI-01740 Vantaa, Finlandherewith declares that the compon<strong>en</strong>tPC, PCD, PBD, <strong>PCJ</strong>, FMP, FSS, FKS, FTPE air coolerPCG, PCDG, PBDG, <strong>PCJ</strong>G, FMPG liquid coolerwhich is not able to function indep<strong>en</strong>d<strong>en</strong>tly is int<strong>en</strong>ded to be incorporated into machinery or to be assembledwith other machinery to constitute machinery covered by Directive 2006/42/EC and changes related to it andwith national implem<strong>en</strong>ting legislation meant machinery.By designing of the compon<strong>en</strong>t the following directives have be<strong>en</strong> applied:2006/42/EC, 2004/108/EC, 97/23/ECand the following harmonized standards have be<strong>en</strong> applied:ISO-EN 12100:2010, SFS-EN ISO 13857, SFS-EN 60204-1,SFS-EN 61000-6-1, SFS-EN 61000-6-3, SFS-EN 61000-6-4and furthermore declares that is not allowed to put the machinery into service until the machinery into which itis to be incorporated or of which it is to be a compon<strong>en</strong>t has be<strong>en</strong> found and declared to be in conformity withthe provisions of Directive 2006/42/EC and with national implem<strong>en</strong>ting legislation including the machineryreferred to in this declaration.Vantaa, February 7, 2012Silja BeierschoderQuality Manager