InstallationAfter installing the mixing valve, be sure to fl ush thesystem of debris. Lawler recommends isolation andcheck valves for proper maintenance.Typical Installation Figure 1When installed without a recirculation system:Install the valve as shown in Figure 1 with the mix ingvalve positioned below the hot water tank or heater.If this is not possible, pipe in heat trap as shown.Typical Installation Figure 2When installed with a recirculating pump on the hotwater supply line only:Note: If the valve is installed 20 feet or more fromthe wa ter heater, it is important to recirculate the hotwater supply to the mixing valve.Install the mixing valve as shown in Figure 2. Thenon-circulated loop should be limited to 10 feet andmust be fl ushed periodically.Caution: The cold water line must be installedso that it is not affected by excessively hot ambienttem per a tures. Provisions shall be madeto thermally isolate the valve. Cold water pipein stalled in the ceil ings of boil er rooms or roomsthat increase ambient temperature require a recirculatingpump.Figure 1Typical installation. <strong>Valve</strong> must beinstalled with check valves.WaterHeaterCWHeat Trap27″ DropHWStorageTankFigure 2Typical installation. <strong>Valve</strong> must beinstalled with check valves.<strong>Series</strong> <strong>911</strong>E/F1 valve pereye wash fixture<strong>Eye</strong>/Face<strong>Wash</strong>Note: The mixing valve must be installed withinlet check valves and the <strong>Eye</strong>wash/Facewashfi x ture should be installed 4 to 10 feet fromthe mix ing valve.CW<strong>Series</strong> <strong>911</strong>E/FNote: The valve body must be maintained at anambient room temperature of above 50°F to preventpremature closure of the safety back-seatmech a nism.Heat Trap27″ DropMaximum Inlet Pressure: 125 PSI.Recommended Supply Pressure: 65 PSI.Recommended Inlet Temperature: 120°F.**When supplying 140°F or greater, additional outletcontrols should be used.We guarantee the Lawler Mixing <strong>Valve</strong> to be freefrom defects in workmanship and material, and,for a period of one year from date of purchase,will replace any parts found by Lawler Man u fac -tur ing Co., Inc. to be defective. We will not be heldGUARANTEE(3)WaterHeaterStorageTankRecirculating Pumpresponsible, how ev er, for any labor in ci den tal to,or for any dam ag es caused by, de fec tive ma te ri al.Each mix ing valve is thor ough ly in spect ed and testedunder ac tu al con di tions at our factory.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!