Appendix A : Conduit Entry for Class 1,<br />

Div 2 Applications<br />

6.33<br />

9.46<br />

0.94<br />

1.688<br />

AUG<br />

0<br />

FOR CONSTRUCTION<br />

RPC SN 14/02<br />

Product Group<br />

ULTRASONICS<br />

NONE<br />

14/ AUG / 02<br />

R. CLYSDALE<br />

T. ADAM<br />

S. NGUYEN<br />

PETERBOROUGH<br />

HINGED 6 X 9 ENCLOSURE WITH<br />

CONDUIT ENTREES & ASSEMBLE<br />

FOR CLASS 1 DIV 2 APPLICATIONS<br />

23650314 0<br />

2365031400<br />

1 : 1 1 2<br />

Appendix A<br />

0.875<br />

1.50<br />

DRILL FOR 1/2”<br />

CONDUIT HUBS<br />

3.25<br />

4.625<br />

2.62<br />

DRILL FOR 3/4”<br />

CONDUIT HUB<br />

NOTES:<br />

1) USE ONLY CONDUIT HUBS CERTIFIED / APPROVED AS TYPE 4X.<br />

2) NON METALLIC ENCLOSURE DOES NOT PROVIDE GROUNDING BETWEEN CONDUIT CONNECTIONS.<br />

USE GROUNDING TYPE BUSHINGS AND JUMPER WIRES.<br />

3) DIMENSIONS INCHES<br />

WARNING: EXPLOSION HAZARD – SUBSTITUTION OF COMPONENTS MAY IMPAIR<br />

SUITIBILITY FOR CLASS I, DIVISION 2<br />