The SEL-2730M Managed 24-Port <strong>E<strong>the</strong>rnet</strong> Switch is a tough, easy-to-use managed<br />

<strong>E<strong>the</strong>rnet</strong> <strong>switch</strong> <strong>designed</strong> <strong>specifically</strong> <strong>for</strong> <strong>the</strong> <strong>utility</strong> <strong>and</strong> <strong>industrial</strong> <strong>markets</strong>.<br />

2


The SEL-2730M provides an <strong>E<strong>the</strong>rnet</strong> local-area network (LAN) communications solution<br />

<strong>for</strong> substation communication.<br />

The goal at SEL is to provide our customers with a fully integrated substation<br />

communications system.<br />

3


In creating <strong>the</strong> SEL-2730M, SEL applied decades of experience building protection,<br />

control, <strong>and</strong> automation solutions, with <strong>the</strong> goal of providing a more integrated substation<br />

communications system that is robust, reliable, secure <strong>and</strong> easy to use.<br />

4


In a typical substation communications application, <strong>the</strong>re are many message types that must<br />

be prioritized <strong>and</strong> sent to <strong>the</strong> appropriate devices—both within <strong>the</strong> substation <strong>and</strong> also<br />

externally to <strong>the</strong> network operations center via <strong>the</strong> ICON Integrated Communications<br />

Optical Network access to a wide-area network (WAN). These message types include<br />

IEC 61850 Generic Object-Oriented Substation Event (GOOSE), supervisory control <strong>and</strong><br />

data acquisition (SCADA), engineering management, <strong>and</strong> security messages.<br />

Note that whenever messages are passed into or out of <strong>the</strong> substation, <strong>the</strong>y must be meet<br />

certain security requirements, which are h<strong>and</strong>led in this example by <strong>the</strong> SEL-3620 <strong>E<strong>the</strong>rnet</strong><br />

Security Gateway.<br />

5


The SEL-2730M is <strong>designed</strong> <strong>and</strong> tested to IEEE 1613 Class 2 <strong>and</strong> IEC 61850-3 st<strong>and</strong>ards,<br />

which require uninterrupted operation <strong>for</strong> mission-critical communications during<br />

electromagnetic interference (EMI) stress <strong>and</strong> environmental testing. IEC 60255 covers<br />

vibration testing, including endurance, shock, <strong>and</strong> earthquake st<strong>and</strong>ards.<br />

KEMA <strong>and</strong> UL certification testing of <strong>the</strong> SEL-2730M are in progress. KEMA certification<br />

indicates that <strong>the</strong> <strong>switch</strong> is fully compliant with its st<strong>and</strong>ards. UL certification is required in<br />

many <strong>industrial</strong> applications.<br />

6


Looking at <strong>the</strong> port configuration options, <strong>the</strong> base model SEL-2730M comes with<br />

20 copper <strong>E<strong>the</strong>rnet</strong> ports—16 are 10/100 Mbps <strong>and</strong> 4 are Gigabit <strong>E<strong>the</strong>rnet</strong>.<br />

The modular design allows <strong>the</strong> 10/100 drop ports to be upgraded to 10/100 fiber ports,<br />

which can be ei<strong>the</strong>r single-mode or multimode.<br />

The SEL-2730M can also be populated with four small <strong>for</strong>m-factor pluggable (SFP) cages<br />

to support SFP transceivers with LC-type connectors. These may also be ei<strong>the</strong>r singlemode<br />

or multimode. The transceivers can be added in <strong>the</strong> field while <strong>the</strong> <strong>switch</strong> is in<br />

operation. Adding all four SFP transceivers creates a total of 8 gigabits of uplink capability.<br />

7


The various SFP transceiver options <strong>for</strong> use in <strong>the</strong> SEL-2730M are shown on <strong>the</strong> slide. One<br />

available option is even rated <strong>for</strong> 80 kilometers, which is useful <strong>for</strong> long distances when<br />

trying to meet network requirements.<br />

Note that <strong>the</strong> <strong>switch</strong> will not work with third-party SFP transceivers. SEL <strong>designed</strong> <strong>the</strong><br />

<strong>switch</strong> this way in order to ensure that <strong>the</strong> entire product, including <strong>the</strong> SFP transceivers,<br />

fully meets industry st<strong>and</strong>ards.<br />

The SFP transceivers can be installed in <strong>the</strong> field <strong>and</strong> are hot swappable, allowing upgrades<br />

to occur while <strong>the</strong> <strong>switch</strong> is in operation.<br />

With 8 gigabits of uplink capability, <strong>the</strong> SEL-2730M is ready to h<strong>and</strong>le exp<strong>and</strong>ing uplink<br />

needs <strong>for</strong> years to come as <strong>the</strong> smart grid data requirements grow.<br />

8


The SEL-2730M comes st<strong>and</strong>ard in a 1 RU-high, 19-inch rack-mount <strong>for</strong>m factor with one<br />

power supply. An ordering option is also available <strong>for</strong> an additional power supply, which<br />

provides <strong>the</strong> capability to have hot swappable dual redundancy.<br />

The benefit of having dual power supplies is that each power supply may be connected to a<br />

separate power source, a substation battery on one <strong>and</strong> ac power on <strong>the</strong> o<strong>the</strong>r. In <strong>the</strong> event<br />

that one source fails or is not available, <strong>the</strong> unit remains in service. In <strong>the</strong> unlikely event<br />

that a power supply fails, <strong>the</strong> failed power supply can be swapped without having to take<br />

<strong>the</strong> unit out of service.<br />

9


The SEL-2730M has several key features associated with <strong>switch</strong> traffic management.<br />

Unlike o<strong>the</strong>r messaging protocols, <strong>E<strong>the</strong>rnet</strong> messages do not time out or expire. This can<br />

cause a problem of messages endlessly looping through <strong>the</strong> system. Rapid Spanning Tree<br />

Protocol (RSTP) is a methodology <strong>designed</strong> <strong>specifically</strong> to quickly <strong>and</strong> effectively pass<br />

messages through <strong>the</strong> network without trapping <strong>the</strong>m in an endless loop. RSTP keeps track<br />

of port availability <strong>and</strong> ensures that messages are routed to only those ports that are<br />

available, thus ensuring <strong>the</strong> fastest transport of priority messages.<br />

10


Virtual local-area networks (VLANs) allow network traffic to be isolated between groups<br />

of intelligent electronic devices (IEDs) or by GOOSE message type.<br />

11


Utilizing <strong>E<strong>the</strong>rnet</strong> class of service (CoS) methodologies minimizes latency <strong>for</strong> missioncritical<br />

applications.<br />

12


Finally, Simple Network Time Protocol (SNTP) client mode synchronizes network<br />

resources <strong>and</strong> provides a synchronized network time stamp.<br />

13


The SEL-2730M has several essential security features built in.<br />

Simple Network Management Protocol Version 3 (SNMPv3) provides a st<strong>and</strong>ardized method to work with<br />

o<strong>the</strong>r network management systems (NMSs), as well as <strong>the</strong> SEL-5051 Network Management Software. The<br />

SEL-2730M is also compatible with SNMP Version 2 (SNMPv2) to work with o<strong>the</strong>r NMS software.<br />

SNMPv3 provides <strong>the</strong> following security features:<br />

• Message integrity, which ensures a packet has not been tampered with while in transit.<br />

• Au<strong>the</strong>ntication, which determines that <strong>the</strong> message is from a valid source.<br />

• Encryption, which scrambles <strong>the</strong> contents of a packet to prevent it from being seen by an unauthorized<br />

source.<br />

This level of security allows data to be collected securely from SNMP devices without <strong>the</strong> fear of data<br />

tampering or corruption.<br />

And confidential in<strong>for</strong>mation (e.g., SNMP SET comm<strong>and</strong> packets that change router configuration) can be<br />

encrypted to prevent <strong>the</strong> contents from being exposed on <strong>the</strong> network.<br />

Security logging is supported <strong>and</strong> is settable <strong>and</strong> viewable from <strong>the</strong> web interface.<br />

User-based accounts are supported. The interface is just like a Microsoft ® Windows ® login.<br />

Using port-based security, <strong>the</strong> SEL-2730M allows users to create access lists <strong>and</strong> restrict port access to<br />

legitimate stations using one of three methods: Static Lock, Count Lock, or Time Lock mode.<br />

Finally, all rear ports may be turned on or off (activated or deactivated) via <strong>the</strong> web interface to meet<br />

security requirements.<br />

14


Installing, configuring, <strong>and</strong> maintaining <strong>the</strong> SEL-2730M is easy <strong>and</strong> convenient.<br />

A laptop, smart phone, or o<strong>the</strong>r web-enabled device can be used to access <strong>the</strong> simple <strong>and</strong><br />

secure web interface.<br />

Switch parameters can also be set in an office. The configuration can <strong>the</strong>n be delivered to<br />

remote devices using a third-party NMS.<br />

The status <strong>and</strong> parameters of <strong>the</strong> SEL-2730M can be monitored using <strong>the</strong> SEL-5051<br />

software via an ICON monitor.<br />

15


Ano<strong>the</strong>r key feature of <strong>the</strong> SEL-2730M is <strong>the</strong> simple, plug-<strong>and</strong>-play design.<br />

The <strong>switch</strong> is <strong>designed</strong> to use immediately as an unmanaged <strong>switch</strong> that can be configured<br />

<strong>for</strong> managed operations at a later time.<br />

Commissioning <strong>and</strong> setting up <strong>the</strong> SEL-2730M is easy using <strong>the</strong> captive portal. The captive<br />

portal technique directs <strong>the</strong> user to a special webpage used <strong>for</strong> au<strong>the</strong>ntication purposes<br />

be<strong>for</strong>e allowing access to <strong>the</strong> Internet. This effectively turns <strong>the</strong> web browser into an<br />

au<strong>the</strong>ntication device.<br />

When configuring <strong>the</strong> <strong>switch</strong>, setup is very straight<strong>for</strong>ward <strong>and</strong> intuitive. The setup<br />

procedures were developed with non-IT personnel in mind, <strong>and</strong> it requires minimal port<br />

settings.<br />

16


The SEL-2730M can be front- or rear-mounted, allowing <strong>the</strong> uplink <strong>and</strong> downlink ports to<br />

be visible on <strong>the</strong> front of <strong>the</strong> rack.<br />

Ano<strong>the</strong>r option includes <strong>the</strong> use of con<strong>for</strong>mal coating, which is used in environments that<br />

are subject to corrosive chemicals, salt spray (marine), or high humidity.<br />

17


The numerous ordering options available with <strong>the</strong> SEL-2730M are shown on <strong>the</strong> slide.<br />

18


The SEL-2730M base model is priced at $1,850. It will be available in <strong>the</strong> second quarter<br />

of 2012.<br />

19


SEL builds <strong>switch</strong>es in our U.S.-based manufacturing facilities, using <strong>the</strong> same processes<br />

we use to build relays. SEL offers <strong>the</strong> same ten-year, worldwide warranty <strong>for</strong> our<br />

communications equipment that we do <strong>for</strong> our protection <strong>and</strong> automation equipment.<br />

20


SEL provides a fully integrated communications system <strong>designed</strong> <strong>specifically</strong> to address<br />

<strong>the</strong> unique requirements of <strong>the</strong> substation. The SEL-2730M is tough, reliable, secure, <strong>and</strong><br />

easy to use. It also is a key component of <strong>the</strong> LAN communications solution.<br />

21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!