Parameter Macros 06/05<br />

Sink<br />

Source<br />

Parameter Description DO Parameter Description DO<br />

p1120<br />

p1121<br />

Ramp-function generator<br />

ramp-up time Vector 20 s Vector<br />

Ramp-function generator<br />

ramp-down time Vector 30 s Vector<br />

p1135 OFF3 ramp-down time Vector 10 s Vector<br />

p1200 FlyRest oper mode Vector 0 Flying restart inactive Vector<br />

p1240 Vdc controller configuration Vector 0 Vdc-max controller enabled Vector<br />

p1280<br />

p1300<br />

p1911<br />

p2051[0]<br />

p2051[1]<br />

p2051[2]<br />

p2051[3]<br />

p2051[4]<br />

p2051[5]<br />

p2080[0]<br />

p2080[1]<br />

p2080[2]<br />

p2080[3]<br />

p2080[4]<br />

p2080[5]<br />

p2080[6]<br />

p2080[7]<br />

p2080[8]<br />

p2080[9]<br />

Vdc controller configuration<br />

(V/f) Vector 0 Vdc-max controller enabled Vector<br />

Open-loop/closed-loop<br />

control operating mode Vector 20 Speed control (sensorless) Vector<br />

Number of phases to be<br />

identified Vector 3 3 phases Vector<br />

CI: PROFIBUS PZD send<br />

word Vector r2089[0] ZSW1 Vector<br />

CI: PROFIBUS PZD send<br />

word Vector r0063 n-act Vector<br />

CI: PROFIBUS PZD send<br />

word Vector r0068 I-act Vector<br />

CI: PROFIBUS PZD send<br />

word Vector r0080 M-act Vector<br />

CI: PROFIBUS PZD send<br />

word Vector r0082 P-act Vector<br />

CI: PROFIBUS PZD send<br />

word Vector r2131 FAULT Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[0] Ready to power up Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[1] Ready to run Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[2] Warning Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r2139[3] Fault Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[4] OFF2 inactive Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[5] OFF3 inactive Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[6] Power-on inhibit Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r2139[7] Alarm present Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r2197[7]<br />

No setpoint/actual value<br />

deviation<br />

Vector<br />

BI: PROFIBUS send status<br />

word 1 Vector r0899[9] Control from the PLC Vector<br />

Parameter Macros-2<br />

SINAMICS G150<br />

Operating Instructions