electrical appliance) or your spa may not function<br />

properly. For safety purposes, the location of the<br />

power outlet (where the spa is to be connected)<br />

can be no closer than the minimum allowable<br />

distance specified by the national and local<br />

wiring rules in your area. Installation must be in<br />

accordance with all national and local wiring<br />

rules.<br />

Fill Spa before Powering on: Always fill the spa<br />

to the recommended level before turning on the<br />

power (see Pre-fill Checklist).<br />

Residual Current Device: The appliance should<br />

be supplied through a residual current device<br />

with a rated tripping current not exceeding<br />

30mA.<br />

WARNING: Never use an extension cord.<br />

Bullfrog International, LC does not allow the<br />

use of an extension cord under any possible<br />

situation. The use of an extension cord voids any<br />

warranty on the spa equipment and also exposes<br />

the consumer to additional risk of fire, electrical<br />

shock, injury, or death.<br />

120V~/60Hz Permanently-Connected<br />

Installation: Unless your spa was ordered from<br />

the factory with a 120V~/60Hz power cord, its<br />

equipment is configured to operate on 230V~/<br />

60Hz power (even though it was equipped with a<br />

120V~/60Hz pump). Prior to the 120V~/60Hz<br />

electrical installation, the spa’s equipment will<br />

need to be converted from its 230V~/60Hz<br />

configuration to a 120V~/60Hz configuration.<br />

For specific conversion instructions, please refer<br />

34<br />

to the system wiring diagram inside the Control<br />

System Box (located in the spa’s equipment<br />

compartment).<br />

Permanently-Connected 120V~/60Hz spas<br />

require a GFCI protected, 3-wire (Line 1,<br />

Neutral and Ground), 120V~/60Hz, 20A,<br />

Single-Phase, dedicated electrical circuit. It is<br />

important that this circuit is dedicated (not being<br />

used by any other electrical appliance) or the spa<br />

may not function properly. Installation must be<br />

in accordance with all national and local wiring<br />

rules.<br />

230V~/60Hz Permanently-Connected<br />

Installation: Even though the spa is equipped<br />

with a 120V~/60Hz pump, it has already been<br />

configured to operate on 230V~/60Hz power<br />

unless the spa came with a factory connected<br />

120V~/60Hz power cord, in which case the spa’s<br />

equipment will need<br />

to be converted from its 120V~/60Hz<br />

configuration to the 230V~/60Hz configuration.<br />

For specific conversion instructions, please refer<br />

to the system wiring diagram inside the Control<br />

System Box (located in the spa’s equipment<br />

compartment).<br />

Permanently-Connected 230V~/60Hz spas<br />

require a GFCI protected, 4-wire (Line 1, Line<br />

2, Neutral, and Ground), 230V~/60Hz, 50A,<br />

Single-Phase, dedicated electrical circuit.<br />

It is important that this circuit is dedicated (not<br />

being used by any other electrical appliance) or<br />

the spa may not function properly. Installation<br />

must be in accordance with all national and local<br />

wiring rules.<br />

230V~/60Hz Pump: Spas equipped with a<br />

230V~/60Hz pump can only be Permanently-<br />

Connected.230V~/60Hz Permanently-<br />

Connected Installation: Your spa has been<br />

configured to operate only on 230V~/60Hz<br />

power.<br />

Permanently-Connected 230V~/60Hz spas<br />

requires a GFCI protected, 4-wire (Line 1, Line<br />

2, Neutral and Ground), 230V~/60Hz, 50A,<br />

Single-Phase, dedicated electrical circuit.<br />

It is important that this circuit is dedicated (not<br />

being used by any other electrical appliance) or<br />

the spa may not function properly. Installation<br />

must be in accordance with all national and local<br />

wiring rules.<br />

230V~/60Hz Equipment (Model BF05-U.S./<br />

CAN Dual-Pump Spas)All spas not listed as voltage<br />

convertable are equipped with (model BF05)<br />

230V~/60Hz equipment. This equipment only<br />

operates on a 230V~/60Hz electrical service.<br />

Permanently-Connected 230V~/60Hz spas require<br />

a GFCI protected, 4-wire (Line 1, Line 2, Neutral<br />

and Ground), 230V~/60Hz, 50A, Single-Phase,<br />

dedicated electrical circuit.<br />

It is required that this circuit is dedicated (not being<br />

used by any other electrical appliance) or the spa<br />

may not function properly. Installation must be in<br />

accordance with all national and local wiring rules.