The Celcon Thin-Joint System A Definitive Guide - Masonry First
The Celcon Thin-Joint System A Definitive Guide - Masonry First
The Celcon Thin-Joint System A Definitive Guide - Masonry First
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Solid external walls Solid wall construction shows the<br />
<strong>Celcon</strong> <strong>Thin</strong>-<strong>Joint</strong> <strong>System</strong> at its full potential. Applying Celfix Mortar<br />
with either a ‘scoop’ or alternatively with a ‘sledge’, which is specifically<br />
designed for use with solid wall construction, the superstructure of a<br />
dwelling can be completed in 2-3 days. <strong>The</strong> <strong>Celcon</strong> <strong>Thin</strong>-<strong>Joint</strong> <strong>System</strong><br />
offers the designer a choice of solutions with the benefit of both<br />
strength and thermal insulation. <strong>The</strong> use of thin layer mortar techniques<br />
give greatly improved U-values of up to 20% when compared to<br />
conventional joints in solid external walls and can meet the thermal<br />
regulations without the need for additional insulation.<br />
Partitions Ideally suited for the construction of partition walls, the <strong>Celcon</strong> <strong>Thin</strong>-<strong>Joint</strong><br />
<strong>System</strong> adds to the existing benefits offered by <strong>Celcon</strong> blocks, such as excellent sound<br />
insulation and high fire resistance. With the speed of build and the mortar setting more quickly,<br />
it is possible for the walls to be finished i.e. plastered, without delay. <strong>The</strong> <strong>Celcon</strong> <strong>Thin</strong>-<strong>Joint</strong><br />
<strong>System</strong> also allows greater flexibility and more choice in applied finishes, see Page 17. <strong>The</strong>se<br />
benefits can be further enhanced when Jumbo Plus Blocks are used to build partition walls.<br />
Separating walls Separating and flanking walls constructed with the <strong>Celcon</strong><br />
<strong>Thin</strong>-<strong>Joint</strong> <strong>System</strong> satisfy the sound insulation requirements of the National Building<br />
Regulations allowing the building to benefit from the construction speed of the <strong>Celcon</strong><br />
<strong>Thin</strong>-<strong>Joint</strong> <strong>System</strong> whilst retaining an homogeneous build system. For further details see<br />
<strong>Celcon</strong>’s <strong>Guide</strong> to Part E Sound Insulation Regulations or contact our Technical Services<br />
Department for detailed advice on constructions meeting the requirements for separating and<br />
flanking walls.<br />
Foundations Celfix Mortar is suitable for use in classes DS1 and DS2 soil and<br />
groundwater conditions as defined in Table 2 of BRE Special Digest 1 - Concrete in aggressive<br />
ground Part 1:2001.<br />
Extensions Whether the wall is solid or cavity construction, the <strong>Celcon</strong> <strong>Thin</strong>-<strong>Joint</strong> <strong>System</strong><br />
is ideal when building extensions. <strong>The</strong> inherent speed of build enables quicker construction<br />
times, excellent thermal efficiency meeting today’s thermal requirements, reduced wastage of<br />
blocks and mortar and a potentially cleaner site.<br />
<strong>The</strong> <strong>Celcon</strong> <strong>Thin</strong>-<strong>Joint</strong> <strong>System</strong> 2<br />
5