19.01.2016 Views

000-fl-fld-eng

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ELINEFLD<br />

FLD DATA BUSBAR MOUNTING<br />

1<br />

2<br />

3<br />

4<br />

A<br />

A<br />

M6 Dowel<br />

1-Determine the required<br />

mounting height of FLD Data<br />

Busbar and mark the position.<br />

2-Check the horizontal level using a<br />

spirit level and mark the location of<br />

the rawlplug holes using a l<strong>eng</strong>th of<br />

FLD Data Busbar.<br />

3-Drill the marked positions<br />

using a hand drill and M6 bit.<br />

4-Place M6 rawlplugs in the<br />

holes that are drilled.<br />

5<br />

6 7<br />

8<br />

5-Secure FLD Data Busbar on<br />

the wall using appropriate<br />

washer and screw.<br />

6-Place FL Busbar in the<br />

trunking securing the clamps in<br />

their places.<br />

7-At corner locations, place the FLD<br />

Data Busbar internal and external<br />

corner units installation.<br />

8-At corner locations, install the FLD<br />

Data Busbar FLD Data Busbar internal<br />

and external corner unit covers<br />

securing the clamps in their places.<br />

9 10 11<br />

12<br />

9-Clip on the joint cover piece<br />

central to the joint.<br />

10-Install FLD Data Busbar end<br />

cap termination units securing<br />

them in the clamps.<br />

11-Mark areas on FLD Data<br />

Busbar where Data and Phone<br />

socket will be installed and<br />

neatly cut the cover.<br />

12-Extend Data and Phone<br />

cables through these cut<br />

sections approximately 50cm.<br />

FLD<br />

13 14<br />

15<br />

16<br />

13-Have a qualified technician<br />

drive the cables to RJ45 data<br />

sockets and place the RJ45 data<br />

sockets with the cables driven<br />

on FLD Data Busbar Data &<br />

Phone socket base.<br />

14-Place FLD Data Busbar<br />

Data&Phone Socket Base on the<br />

trunking.<br />

15-Push FLD Data Busbar cover<br />

and tighten socket base.<br />

16-Make sure FLD Data Busbar<br />

and all its accessories are<br />

complete and finish mounting.<br />

FLD DATA BUSBAR minimum offset return distance is 20 cm. Order special<br />

modules by submitting dimensions for off-set returns lower than 20 cm.<br />

Caution: FLD Data Busbar and Cover can be cut during mounting; a stand saw is recommended for this.<br />

23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!