Caution!<br />
The brake torque can be neutralized manually by means of the hand release lever (29). Consequently, the<br />
brake must be installed in such a way that any unintentional actuation of the hand release lever (29) is<br />
excluded and that perfect operation of the spring-applied brake is ensured. The hand release lever (29) must<br />
not be used to release the brake during normal operation.<br />
<strong>Kendrion</strong> <strong>Binder</strong> <strong>Magnete</strong> <strong>GmbH</strong> Operating Instructions 76 ..E..B00 Date of issue: 24.01.2005 Page 8<br />
Size<br />
10 11 13 16 19 24<br />
Release force F [N] approx. 18 approx. 35 approx. 45 approx. 90 approx. 85 approx. 170<br />
Max. release force (operating force Fmax<br />
[N]<br />
50 50 125 125 240 240<br />
Tab 8/1: Release force und setting dimensions of hand release lever<br />
Warning:<br />
The mechanic hand release lever (29) must be in centre position when not actuated (see fig. 6.1), as only in<br />
this position a fully engaged brake can be ensured. If this is not achieved, it cannot be ensured that the full<br />
braking effect of the spring-applied single-disc brake is reached. In this case the user shall immediately stop<br />
the equipment and/or machine (e.g. motor). The brake can only be put into operation, if the proper<br />
functioning of the hand release lever (29) and the automatic return movement of the hand release lever in<br />
the centre position are ensured (see. fig. 6/1).