DRY RUN CONVERSION<br />
FITTING PROCEDURE<br />
Date: 03/11/2015<br />
Ref No: DRP<br />
13<br />
14<br />
Remove the BLUE wire from terminal 8 cut off the bootlace crimp,<br />
connect BLUE wire 8 from the AC to DC convertor to this wire using<br />
the twin bootlace crimp provided and then refit these wires into<br />
terminal 8.<br />
Remove the BROWN wire from terminal 9 cut off the bootlace crimp,<br />
connect BROWN wire 9 from the AC to DC convertor to this wire<br />
using the twin bootlace crimp provided and then refit these wires into<br />
terminal 9.<br />
15 Remove the wire linking terminals 3 and 4<br />
16 Connect the BLACK wire 4 from the dry run probe to terminal 4.<br />
17 Connect the GREY wire 3 from the dry run probe to terminal 3.<br />
18<br />
19<br />
Connect the BROWN wire X from the dry run probe to the 24 V DC +<br />
terminal on the 24 volt AC to DC converter.<br />
Connect the BLUE wire from the dry run probe to the 24 V DC -<br />
terminal on the 24 volt AC to DC converter.<br />