24.05.2016 Views

Separator Bible

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

L2<br />

2 T1 4 T2 6 T3<br />

E<br />

1 2 3 E 4 5 6 E 7 8 E 9 10 E 11 12 13 14<br />

19 20 21 22 E<br />

28 29 30 31<br />

Link if not fitted<br />

Link if not fitted<br />

Link if not fitted<br />

Link if not fitted<br />

E E 15 16 E 17 18 E<br />

23 24 25 26 E 27 E<br />

CP4 Probe<br />

RL2<br />

RL1<br />

COM<br />

L<br />

N<br />

E<br />

Q1<br />

L1 L2 L3 E<br />

L1 L2 L3 E<br />

D<br />

S<br />

Heater<br />

Thermostat<br />

0-20 mA<br />

4-20 mA<br />

Analogue<br />

Output<br />

J 8<br />

1<br />

+<br />

4-20 mA<br />

J11<br />

RS232<br />

J 9<br />

SW1<br />

bk<br />

gr<br />

J 7<br />

SW2<br />

Smart Cell<br />

SUPPLY IN AUTO CLEAN SAMPLE CLEAN ALARM 1 ALARM 2<br />

L E N L E N L E N 1 2 3 1 2 3<br />

br<br />

br<br />

Customer<br />

Volt Free<br />

Connect to Smart Cell<br />

5 core HOFR cable<br />

Victor supply<br />

Alarm 2 relay contacts<br />

N/C in power down &<br />

alarm active states<br />

(Annunciation only)<br />

E N L<br />

g/y<br />

bl<br />

br<br />

DIVERTER VALVE SOL<br />

3 core HOFR cable<br />

Victor supply<br />

br bl gr bk<br />

6 5 4 3 2 1<br />

+<br />

Heater Thermostat<br />

Spare<br />

OCD <strong>Separator</strong> Run Status<br />

Emergency<br />

Stop<br />

Option<br />

If Fitted<br />

<strong>Separator</strong> Feed Pump Motor<br />

Heater Power<br />

OCD Power<br />

Remote Emergency Stop<br />

(Link if not fitted)<br />

Oil Detection Probe Power<br />

1st Stage Oil Discharge Valve<br />

2nd Stage Flush Valve<br />

LS1 Low Level in Bilge Tank<br />

(Link if not fitted)<br />

LS2 High Level in Oil Tank<br />

(Link if not fitted)<br />

Dry Run Protection Device<br />

Remote Start<br />

Remote Stop<br />

(Link if not fitted)<br />

Main Power<br />

Cable Supplied by Customer<br />

Motor<br />

Heater<br />

1st Stage<br />

Oil Discharge<br />

Valve<br />

1<br />

SV1<br />

2<br />

E<br />

2 nd Stage<br />

Flush Valve<br />

1<br />

SV2<br />

2<br />

E<br />

LS1 Bilge Tank Low Level<br />

Break on LowLevel<br />

Customer supply and fit<br />

LS2 Oil Tank High Level<br />

Break on High Level<br />

Customer supply and fit<br />

Start<br />

(Remote)<br />

Stop<br />

(Remote)<br />

Option<br />

Customer supply and fit<br />

3<br />

4<br />

2<br />

1<br />

<strong>Separator</strong> feed pump running volt free<br />

<strong>Separator</strong> feed pump tripped volt free<br />

<strong>Separator</strong> Heater tripped volt free<br />

<strong>Separator</strong> Power On volt free<br />

Victor supply<br />

Customer supply and fit<br />

Victor supply<br />

Victor supply Victor supply<br />

32 34 36 38<br />

33 35 37 39<br />

IMO Data Download port<br />

1 L1 3 5 L3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!