15.06.2016 Views

Cole-Hersee - D-275-MasterCatalog

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

H4<br />

solenoids & relays<br />

MODULES<br />

H<br />

48785 Electronic Solenoid<br />

85A, 9V-31V DC. Fully solid-state, with no moving parts to<br />

wear out. The Electronic Solenoid stands up to over 20 million<br />

On-Off cycles. It is completely sealed, ignition protected,<br />

and withstands vibration and adverse environments. Perfect<br />

for vehicles that are always on the move. Use the Electronic<br />

Solenoid in both 12V or 24V applications... or any voltage<br />

between 9 and 31V.<br />

• Solenoid can be used in both High Side and<br />

Low Side switching applications.<br />

• Needs only a very low control current.<br />

• Suitable for high inrush demand circuits.<br />

24452 Forward & Reverse Relay Module<br />

Reversing module carries a heavy load and is suitable for<br />

intermittent or continuous operation at 12V DC. Ideal for<br />

tarp or lift applications as well as for hoists, hatches,<br />

winches/windlasses, snowplows, intake/exhaust fans, vehicle<br />

outriggers and many other direction reversing applications.<br />

Fully sealed to accommodate harsh environments. Dynamic<br />

braking stops the motor when the control switch is turned<br />

to Off. Low profile module (less than 2" high) saves space in<br />

cramped installations. Studs are securely secured in epoxy.<br />

Protective cover 97297 is also available.<br />

NEW<br />

Specifications:<br />

9 - 31V DC, 85A continuous or 175A intermittent.<br />

Low On resistance of .005Ω<br />

Low control current of .02A (max) means lighter wires,<br />

smaller harnesses.<br />

On/Off control voltage must be identical to the system voltage.<br />

Wide temperature operating range -40°C to + 85°C<br />

without derating.<br />

Protected from transient voltage spikes or surges.<br />

BAT<br />

+<br />

Red<br />

Black<br />

+<br />

–<br />

LOAD<br />

BAT<br />

+<br />

Red<br />

Black<br />

LOAD<br />

+<br />

–<br />

Specifications:<br />

High performance silver tin oxide contacts assure long cycle life.<br />

70A at 12V DC intermittent, max On time 5 mins, Off time 3<br />

mins. 50A at 12V DC Continuous. For intermittent operation.<br />

Control switch should be Mom On – Off – Mom On; for<br />

continuous operation On – Off – On.<br />

Load current inrush: 150A. Pull-in voltage 7.8V max.<br />

Low coil current draw. Coil resistance 82 Ohms ± 10%.<br />

Vibration resistance: 10-55Hz. Double amplitude 1.55mm.<br />

Environmental: -40°C to 85°C. Rust and moisture-resistant<br />

plastic housing.<br />

Fully sealed to IP67 with high strength epoxy for total moisture<br />

protection.<br />

Ignition protected.<br />

Tin-plated brass studs and hardware for corrosion resistance.<br />

Dielectric strength: 500V RMS between coil and contact.<br />

High side switching application<br />

Low side switching application<br />

Emergency Cutoff<br />

200A Dual Relay<br />

Can be wired as a Latching Relay or as a Normally Open<br />

Relay. See page 99.<br />

Emergency cutoff switches are commonly mounted on many<br />

types of vehicles such as buses, and those used in construction<br />

and agriculture. Fire departments routinely familiarize<br />

themselves with the location of cutoffs, so that vehicles can<br />

quickly be isolated in case of emergency. Additionally, OSHA<br />

requires cutoffs on certain vehicles, particularly those with<br />

ancillary motorized equipment,<br />

such as garbage trucks.<br />

See Section J2.<br />

Rapid ship item. BP Available in retail clamshell pack. Minimum order quantity may apply. Part numbers needed in BOX require a -BX suffix on the purchase order.<br />

<strong>Cole</strong> <strong>Hersee</strong> Co. 20 Old Colony Ave, Boston, MA 02127-2467<br />

79<br />

T 617.268.2100 F 617.268.9490 www.colehersee.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!