5. PERFORMANCE DATA<br />
5-1 Performance charts<br />
AER608SCL<br />
� Cooling Characteristics<br />
Notes:<br />
Operating current (A)<br />
Low pressure at wide tube <strong>service</strong> valve MPa<br />
0,90<br />
0,80<br />
0,70<br />
0,60<br />
0,50<br />
0,40<br />
0,30<br />
0,20<br />
0,10<br />
Points of Rating condition<br />
Data referred to indoor unit AWR608CL<br />
6<br />
5<br />
4<br />
3<br />
2<br />
Indoor inlet <strong>air</strong><br />
D.B. (°C)<br />
1<br />
20 25 30 35 40 45<br />
Outdoor inlet <strong>air</strong> D.B. temp. (°C)<br />
Indoor inlet <strong>air</strong><br />
D.B. (°C)<br />
0,00<br />
20 25 30 35 40 45<br />
Outdoor inlet <strong>air</strong> D.B. (°C)<br />
14<br />
32<br />
27<br />
19<br />
32<br />
27<br />
19