TABLE OF CONTENTS<br />

1. Safety Precautions.............................................3<br />

2. Specification .......................................................5<br />

3. Features ..............................................................9<br />

4. Location of Controls and Components..........10<br />

4.1 <strong>Indoor</strong> <strong>Unit</strong>..................................................10<br />

4.2 <strong>Outdoor</strong> <strong>Unit</strong> ...............................................10<br />

4.3 Remote Control ..........................................10<br />

5. Dimensions .......................................................11<br />

5.1 <strong>Indoor</strong> <strong>Unit</strong>..................................................11<br />

5.2 <strong>Outdoor</strong> <strong>Unit</strong> ...............................................12<br />

6. Refrigeration Cycle Diagram...........................13<br />

7. Block Diagram ..................................................14<br />

8. Wiring Diagram.................................................16<br />

9. Printed Circuit Board .......................................19<br />

WARNING<br />

Order No: PAPAGZ120301CE<br />

<strong>Indoor</strong> <strong>Unit</strong> <strong>Outdoor</strong> <strong>Unit</strong><br />

<strong>CS</strong>-<strong>RE9NKE</strong><br />

<strong>CS</strong>-<strong>RE12NKE</strong><br />

<strong>CS</strong>-<strong>RE15NKE</strong><br />

CU-<strong>RE9NKE</strong><br />

CU-<strong>RE12NKE</strong><br />

CU-<strong>RE15NKE</strong><br />

This service information is designed for experienced repair technicians only and is not designed for use by the general public.<br />

It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.<br />

Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service<br />

or repair the products dealt with in this service information by anyone else could result in serious injury or death.<br />

9.1 <strong>Indoor</strong> <strong>Unit</strong>..................................................19<br />

9.2 <strong>Outdoor</strong> <strong>Unit</strong> ...............................................21<br />

10. Installation Instruction.....................................24<br />

10.1 Select the Best Location ............................24<br />

10.2 <strong>Indoor</strong> <strong>Unit</strong>..................................................25<br />

10.3 <strong>Outdoor</strong> <strong>Unit</strong> ...............................................27<br />

11. Service Mode ....................................................30<br />

11.1 Auto OFF/ON Button ..................................30<br />

11.2 Select Remote Control Transmission Code<br />

………………………………………………...30<br />

11.3 Operate and Display of Remote Control ....31<br />

12. Operation Control.............................................33<br />

12.1 Basic Function............................................33<br />

12.2 <strong>Indoor</strong> Fan Motor Operation.......................34<br />

12.3 <strong>Outdoor</strong> Fan Motor Operation ....................34<br />

13. Protection control ............................................37<br />

13.1 Protection Control For All Operations ........37<br />

© Panasonic Appliances Air-Conditioning<br />

(Guangzhou) Co.,Ltd (PAPAGZ) 2012. Unauthorized<br />

copying and distribution is a violation of law.


13.2 Protection Control For Cooling and Soft Dry<br />

Operation...............................................................39<br />

13.3 <strong>Indoor</strong> Piping Air Temperature Control<br />

(Heating)................................................................40<br />

14. Troubleshooting Guide....................................42<br />

14.1 Refrigeration cycle system .........................42<br />

14.2 Breakdown Self Diagnosis Function...........43<br />

15. Disassembly and Assembly Instructions ......45<br />

16. Exploded View and Replacement Pars List...48<br />

16.1 <strong>Indoor</strong> <strong>Unit</strong> ..................................................48<br />

16.2 <strong>Outdoor</strong> <strong>Unit</strong> ...............................................50<br />

2


1. Safety Precautions<br />

• Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing.<br />

• Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the<br />

power plug and main circuit for the model installed.<br />

• The caution items stated here must be followed because these important contents are related to safety. The<br />

meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction<br />

will cause harm or damage, and the seriousness is classified by the following indications.<br />

WARNING This indication shows the possibility of causing death or serious injury<br />

CAUTION<br />

This indication shows the possibility of causing injury or damage to properties.<br />

• The items to be followed are classified by the symbols:<br />

Symbol with white background denotes item that is PROHIBITED from doing.<br />

Symbol with dark background denotes item that must be carried out.<br />

• Carry out test run to confirm that no abnormality occurs after the servicing. Then, explain to user the operation,<br />

care and maintenance as stated in instructions. Please remind the customer to keep the operating instructions for<br />

future reference.<br />

WARNING<br />

1. Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage,<br />

electrical shock or fire.<br />

2. Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical<br />

shock or fire.<br />

3. Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water<br />

leakage, fire or electrical shock.<br />

4. Install at a strong and firm location which is able to withstand the set’s weight. If the strength is not enough or installation<br />

is not properly done, the set will drop and cause injury.<br />

5. Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit at veranda of high rise building,<br />

child may climb up to outdoor unit and cross over the handrail and causing accident.<br />

6. For electrical work, follow the local national wiring standard, regulation and this installation instruction. An independent<br />

circuit and single outlet must be used. If electrical circuit capacity is not enough or defect found in electrical work, it will<br />

cause electrical shock or fire.<br />

7. This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current<br />

Device (RCD). Otherwise, it may cause electrical shock and fire in case equipment breakdown or insulation<br />

breakdown.<br />

8. This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning<br />

rod and telephone. Otherwise, it may cause electrical shock in case equipment breakdown or insulation breakdown.<br />

9. Do not use joint cable for indoor/outdoor connection cable. Use the specified <strong>Indoor</strong>/<strong>Outdoor</strong> connection cable, refer to<br />

installation instructions CONNECT THE CABLE TO THE INDOOR UNIT and connect tightly for indoor / outdoor<br />

connection. Clamp the cable so that no external force will be acted on the terminal. If connection or fixing is not<br />

perfect, it will cause heat up or fire at the connection.<br />

10. Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fixed<br />

perfectly, it will cause fire or electrical shock.<br />

11. When carrying out piping connection, take care not to let air substances other than the specified refrigerant go into<br />

refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, explosion<br />

and injury.<br />

12. Do not use unspecified cord, modified cord, joint cord or extension cord for power supply cord. Do not share the single<br />

outlet with other appliances. Poor contact, poor insulation or over current will cause electrical shock or fire.<br />

13. • For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such<br />

same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and<br />

injury. Use only R410A materials.<br />

• Thickness or copper pipes used with R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm<br />

• It is desirable that the amount of residual oil is less than 40 mg/10 m.<br />

14. During installation, install the refrigerant piping properly before running the compressor. Operation of compressor<br />

without fixing refrigeration piping and valves at opened condition will cause suck-in of air, abnormal high pressure in<br />

refrigeration cycle and result in explosion, injury etc.<br />

15. During pump down operation, stop the compressor before remove the refrigeration piping. Removal of refrigeration<br />

piping while compressor is operating and valves are opened will cause suck-in of air, abnormal high pressure in<br />

refrigeration cycle and result in explosion, injury etc.<br />

3


16. After completion of installation or service, confirm there is no leakage of refrigerant gas. It may generate toxic gas<br />

when the refrigerant contacts with fire.<br />

17. Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with<br />

fire.<br />

18. Recommended installation height for indoor unit shall be at least 2.5 m.<br />

19. The appliance shall be installed in accordance with national wiring regulations.<br />

20. Keep away from small children, the thin film may cling to nose and mouth and prevent breathing.<br />

21. Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long<br />

period, the flare may break and cause refrigerant gas leakage.<br />

22. Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.<br />

23. Do not modify the machine, part, material during repairing service.<br />

24. Must not use other parts except original parts describe in catalog and manual.<br />

25. Do not tie up the power supply cord into a bundle by hand. Abnormal temperature rise on power supply cord may<br />

happen.<br />

26. Do not sit or step on the unit, you may fall down accidentally.<br />

27. Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and<br />

prevent breathing.<br />

28. When install or relocate air conditioner, do not let any substance other than the specified refrigerant, eg.<br />

air etc. mix into refrigeration cycle (piping). Mixing of air etc. will cause abnormal high pressure in<br />

refrigeration cycle and result in explosio.<br />

29. <strong>Indoor</strong> unit must be installed close against the wall.<br />

30.All-pole disconnection incorporated in the fixed wiring is to be provided.<br />

CAUTION<br />

1. Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and accumulates at<br />

surrounding of the unit, it may cause fire.<br />

2. Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room<br />

and damage the furniture.<br />

3. Do not touch outdoor unit air inlet and aluminums fin. It may cause injury.<br />

4. Select an installation location which is easy for maintenance.<br />

5. Power supply connection to the air conditioner.<br />

Connect the power supply cord of the air conditioner to the mains using one of the following methods.<br />

Power supply point should be in easily accessible place for power disconnection in case of emergency.<br />

In some countries, permanent connection of this air conditioner to the power supply is prohibited.<br />

1) Power supply connection to the receptacle using a power plug.<br />

Use an approved 15/16A power plug with earth pin for the connection to the receptacle.<br />

2) Power supply connection to a circuit breaker for the permanent connection. Use an approved 16A circuit breaker for<br />

the permanent connection. It must be a double pole switch with a minimum 3.5 mm contact gap.<br />

6. Do not release refrigerant.<br />

Do not release refrigerant during piping work for installation, re-installation and during repairing a refrigeration parts.<br />

Take care of the liquid refrigerant, it may cause frostbite.<br />

7. Installation or servicing work.<br />

It may need two people to carry out the installation and service work.<br />

8. Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.<br />

9. Do not touch the sharp aluminium fin, sharp parts may cause injury.<br />

10. Thermal fuse specification for indoor unit: 250V 3.15A T3.15AL; outdoor unit: 205V 3.15A T3.15AL,.<br />

4


2. Specification<br />

Model<br />

<strong>Indoor</strong><br />

<strong>Outdoor</strong><br />

<strong>CS</strong>-<strong>RE9NKE</strong><br />

CU-<strong>RE9NKE</strong><br />

<strong>CS</strong>-<strong>RE12NKE</strong><br />

CU-<strong>RE12NKE</strong><br />

Power Supply<br />

Phase, Hz<br />

V<br />

Single, 50<br />

230<br />

Single, 50<br />

230<br />

Min Rate Max Min Rate Max<br />

kW 0.900 2.500 3.000 0.900 3.500 3.900<br />

Capacity<br />

BTU/h 3070 8530 10230 3070 11940 13300<br />

kJ/h 770 2150 2580 770 3010 3350<br />

Running Current A - 3.30 - - 4.70 -<br />

Input Power W 190 700 1000 170 1010 1200<br />

EER<br />

W/W<br />

BTU/hW<br />

4.74<br />

16.16<br />

3.57<br />

12.18<br />

3.00<br />

10.23<br />

5.29<br />

18.06<br />

3.47<br />

11.82<br />

3.25<br />

11.08<br />

Power Factor % 92 93<br />

<strong>Indoor</strong> Noise<br />

dB-A (H / L / QLo)<br />

Power Level<br />

Hi: 42 Lo: 27 QLo: 22<br />

58<br />

Hi: 42 Lo: 30 QLo: 22<br />

58<br />

<strong>Outdoor</strong> Noise<br />

dB-A (H / L )<br />

Power Level<br />

Hi: 47 Lo: -<br />

63<br />

Hi: 48 Lo: -<br />

64<br />

kW 0.900 3.300 4.100 0.900 4.250 5.100<br />

Capacity<br />

BTU/h 3070 11250 13980 3070 14490 17390<br />

kJ/h 770 2840 3530 770 3660 4390<br />

Running Current A - 3.80 - - 5.20 -<br />

Input Power W 170 820 1150 150 1120 1460<br />

COP<br />

W/W<br />

BTU/hW<br />

5.29<br />

18.06<br />

4.02<br />

13.71<br />

3.57<br />

12.16<br />

6.00<br />

20.47<br />

3.79<br />

12.94<br />

3.49<br />

11.91<br />

Power Factor % 93 93<br />

<strong>Indoor</strong> Noise<br />

dB-A (H / L / QLo)<br />

Power Level<br />

Hi: 42 Lo: 27 QLo: 25<br />

58<br />

Hi: 42 Lo: 33 QLo: 25<br />

58<br />

<strong>Outdoor</strong> Noise<br />

dB-A (H / L )<br />

Power Level<br />

Hi: 48 Lo: -<br />

64<br />

Hi: 50 Lo: -<br />

66<br />

Max Current (A) / Max Input Power (W) 6.30 / 1.350k 8.40 / 1.600k<br />

Starting Current (A) 4.00 5.40<br />

Type Hermetic Motor Hermetic Motor<br />

Compressor Motor Type BRUSHLESS (6 poles) BRUSHLESS (6 poles)<br />

Output Power W 750 900<br />

Type Cross-flow fan Cross-flow fan<br />

Material AS(GF30%) AS(GF30%)<br />

Motor Type DC (8 poles) DC (8 poles)<br />

Input Power W - -<br />

Output Power W 30 30<br />

Q-Lo rpm 600 620<br />

Speed Lo rpm 700 790<br />

(COOLING) Me rpm 920 970<br />

Hi rpm 1150 1150<br />

Q-Lo rpm 650 680<br />

Speed Lo rpm 710 830<br />

(HEATING) Me rpm 830 950<br />

Hi rpm 1040 1150<br />

Type Propeller Propeller<br />

Material PP(GF+PD)30% PP(GF+PD)30%<br />

Motor Type DC (8 poles) DC (8 poles)<br />

Input Power W - -<br />

Output Power W 25 40<br />

Speed<br />

Cooling<br />

Heating<br />

rpm<br />

rpm<br />

730<br />

710<br />

730<br />

710<br />

Moisture Removal L/h (Pt/h) 1.4 (2.4) 2.0 (3.5)<br />

O-Lo m 3 /min (ft 3 /m) 6.51 (230) 6.74 (238)<br />

Lo m 3 /min (ft 3 /m) 7.60 (268) 8.58 (303)<br />

Me m 3 /min (ft 3 <strong>Indoor</strong> Airflow<br />

(COOLING)<br />

/m) 10.00(353) 10.54 (372)<br />

Hi m 3 /min (ft 3 /m) 12.5 (441) 12.5(441)<br />

<strong>Indoor</strong> Airflow O-Lo m 3 /min (ft 3 /m) 6.94 (245) 7.39 (261)<br />

COOLING<br />

HEATING<br />

<strong>Indoor</strong> Fan<br />

<strong>Outdoor</strong> Fan<br />

5


Lo m 3 /min (ft 3 /m) 7.57 (267) 9.01 (318)<br />

Me m 3 /min (ft 3 (HEATING)<br />

/m) 8.86 (313) 10.33 (364)<br />

Hi m 3 /min (ft 3 /m) 11.1 (392) 12.5 (441)<br />

Hi (Cooling) m 3 /min (ft 3 <strong>Outdoor</strong> Airflow<br />

Hi (Heating)<br />

/m)<br />

3 3<br />

m /min (ft /m)<br />

31.4 (1108)<br />

31.4 (1108)<br />

33.0 (1165)<br />

33.0 (1165)<br />

Control Device<br />

Refrigerant Oil cm<br />

Capillary Tube Capillary Tube<br />

3 Refrigeration<br />

Cycle<br />

Refrigerant Type g (oz)<br />

FV50S (250)<br />

R410A, 640 (22.6)<br />

FV50S (320)<br />

R410A, 780(27.5)<br />

Dimension Height(I/D / O/D) mm (inch) 290 (11-15/32) 530 (20-55/64) 290 (11-15/32) 540 (21-1/4)<br />

Width (I/D / O/D) mm (inch) 848 (33-13/32) 720(28-11/32) 848 (33-13/32) 780 (30-45/64)<br />

Depth (I/D / O/D) mm (inch) 213(8-3/8) 275 (10-53/64) 213(8-3/8) 289 (11-3/8)<br />

Weight Net (I/D / O/D) kg (lb) 8.0 (18) 20 (44) 8.0 (18) 26(57)<br />

Pipe Diameter (Liquid /<br />

Gas)<br />

mm (inch) 6.35 (1/4) / 9.52 (3/8) 6.35 (1/4) / 9.52 (3/8)<br />

Standard length m (ft) 5 (16.4) 5 (16.4)<br />

Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2) 3 (9.8) ~ 15 (49.2)<br />

I/D & O/D Height different m (ft) 5.0 (16.4) 5.0 (16.4)<br />

Additional Gas Amount g/m (oz/ft) 20 (0.2) 20 (0.2)<br />

Length for Additional Gas m (ft) 7 (23.0) 7 (23.0)<br />

Drain Hose Inner diameter mm 16 16<br />

Length mm 500 500<br />

Fin Material<br />

<strong>Indoor</strong><br />

Fin Type<br />

Heat<br />

Row x Stage x FPI<br />

Exchanger<br />

Size (W x H x L) mm<br />

Pre coated<br />

Slit Fin<br />

2 x 15 x 19<br />

610 x 315 x 25.4<br />

Pre coated<br />

Slit Fin<br />

2 x 15 x 19<br />

610 x 315 x 25.4<br />

Fin Material<br />

<strong>Outdoor</strong><br />

Fin Type<br />

Heat<br />

Row x Stage x FPI<br />

Exchanger<br />

Size (W x H x D) mm<br />

Pre coated<br />

Slit Fin<br />

1 x 24 x 19<br />

661 x 504 x 18.19<br />

Pre coated<br />

Slit Fin<br />

2 x 24 x 17<br />

703x 504 x 18.19<br />

Air Filter<br />

Material<br />

Type<br />

P.P.HONEY COMB<br />

One-touch<br />

P.P.HONEY COMB<br />

One-touch<br />

Power Supply <strong>Indoor</strong> <strong>Indoor</strong><br />

Power Supply Cord A 10A 10A<br />

Thermostat - -<br />

Protection Device - -<br />

Piping<br />

TEMPERATURE (°C )<br />

<strong>Indoor</strong> Operation Range<br />

<strong>Outdoor</strong> Operation Range<br />

COOLING HEATING COOLING HEATING<br />

DB WB DB WB DB WB DB WB<br />

Maximum 32 23 30 - 32 23 30 -<br />

Minimum 16 11 16 - 16 11 16 -<br />

Maximum 43 26 24 18 43 26 24 18<br />

Minimum 16 11 -5 -6 16 11 -5 -6<br />

1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bu lb (66.2°F<br />

Wet Bulb) and outdoor air temperature of 35°C Dry B ulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bu lb).<br />

2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor ai r temperature<br />

of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42 .8°F Wet Bulb).<br />

3. Specifications are subjected to change without prior notice for further improvement.<br />

6


Model<br />

<strong>Indoor</strong><br />

<strong>Outdoor</strong><br />

<strong>CS</strong>-<strong>RE15NKE</strong><br />

CU-<strong>RE15NKE</strong><br />

Power Supply<br />

Phase, Hz<br />

V<br />

Single, 50<br />

230<br />

Min Rate Max<br />

kW 1.000 4.200 4.600<br />

Capacity<br />

BTU/h 3410 14330 15700<br />

kJ/h 860 3610 3960<br />

Running Current A - 6.00 -<br />

Input Power W 210 1260 1650<br />

EER<br />

W/W<br />

BTU/hW<br />

4.76<br />

16.23<br />

3.33<br />

11.37<br />

2.78<br />

9.51<br />

Power Factor % 91<br />

<strong>Indoor</strong> Noise<br />

dB-A (H / L / QLo)<br />

Power Level<br />

Hi: 46 Lo: 31 QLo: 29<br />

62<br />

<strong>Outdoor</strong> Noise<br />

dB-A (H / L)<br />

Power Level<br />

Hi: 50 Lo: -<br />

66<br />

kW 0.900 5.000 6.800<br />

Capacity<br />

BTU/h 3070 17060 23200<br />

kJ/h 770 4300 5850<br />

Running Current A - 6.30 -<br />

Input Power W 210 1385 2280<br />

COP<br />

W/W<br />

BTU/hW<br />

4.28<br />

14.61<br />

3.61<br />

12.31<br />

2.98<br />

10.17<br />

Power Factor % 95<br />

<strong>Indoor</strong> Noise<br />

dB-A (H / L / QLo)<br />

Power Level<br />

Hi: 46 Lo: 34 QLo: 28<br />

62<br />

<strong>Outdoor</strong> Noise<br />

dB-A (H / L)<br />

Power Level<br />

Hi: 51 Lo: -<br />

67<br />

Max Current (A) / Max Input Power (W) 10.5 / 2.280k<br />

Starting Current (A) 6.40<br />

Type Hermetic Motor<br />

Compressor Motor Type BRUSHLESS (6 poles)<br />

Output Power W 700<br />

Type Cross-flow fan<br />

Material AS(GF30%)<br />

Motor Type DC (8 poles)<br />

Input Power W -<br />

Output Power W 30<br />

Speed<br />

(COOLIN<br />

G)<br />

O-Lo<br />

Lo<br />

Me<br />

Hi<br />

rpm<br />

rpm<br />

rpm<br />

rpm<br />

730<br />

800<br />

1040<br />

1320<br />

O-Lo<br />

Speed<br />

Lo<br />

(HEATING<br />

Me<br />

)<br />

Hi<br />

rpm<br />

rpm<br />

rpm<br />

rpm<br />

740<br />

900<br />

1060<br />

1300<br />

Type Propeller<br />

Material PP<br />

Motor Type DC (8 poles)<br />

Input Power W -<br />

Output Power W 40<br />

Speed<br />

Cooling<br />

Heating<br />

rpm<br />

Rpm<br />

750<br />

750<br />

Moisture Removal L/h (Pt/h) 2.4 (4.2)<br />

Q-Lo m 3 /min (ft 3 /m) 8.18 (289)<br />

Lo m 3 /min (ft 3 /m) 8.97 (317)<br />

Me m 3 /min (ft 3 <strong>Indoor</strong> Airflow<br />

(COOLING)<br />

/m) 11.65 (412)<br />

Hi m 3 /min (ft 3 /m) 14.80 (523)<br />

Q-Lo m 3 /min (ft 3 /m) 8.25 (291)<br />

Lo m 3 /min (ft 3 /m) 10.03 (354)<br />

Me m 3 /min (ft 3 <strong>Indoor</strong> Airflow<br />

(HEATING)<br />

/m) 11.82 (417)<br />

Hi m 3 /min (ft 3 /m) 14.50 (512)<br />

COOLING<br />

HEATING<br />

<strong>Indoor</strong> Fan<br />

<strong>Outdoor</strong> Fan<br />

7


Hi (COOLING) m 3 /min (ft 3 <strong>Outdoor</strong> Airflow<br />

Hi (HEATING)<br />

/m)<br />

3 3<br />

m /min (ft /m)<br />

34.1 (1204)<br />

34.1 (1204)<br />

Control Device<br />

Refrigerant Oil cm<br />

Expansion valve<br />

3 Refrigeration<br />

Cycle<br />

Refrigerant Type g (oz)<br />

FV50S (320)<br />

R410A, 920 (32.4)<br />

Dimension Height(I/D / O/D) mm (inch) 290 (11-15/32) 540 (21-1/4)<br />

Width (I/D / O/D) mm (inch) 848(33-13/32) 780 (30-45/64)<br />

Depth (I/D / O/D) mm (inch) 213 (8-3/8) 289(11-3/8)<br />

Weight Net (I/D / O/D) kg (lb) 8.0 (18) 27(60)<br />

Pipe Diameter (Liquid /<br />

Gas)<br />

mm (inch) 6.35 (1/4) / 12.7 (1/2)<br />

Standard length m (ft) 5(16.4)<br />

Length range (min – max) m (ft) 3 (9.8) ~ 15 (49.2)<br />

I/D & O/D Height different m (ft) 5.0 (16.4)<br />

Additional Gas Amount g/m (oz/ft) 20 (0.2)<br />

Length for Additional Gas m (ft) 7 (23.0)<br />

Drain Hose Inner diameter mm 16<br />

Length mm 500<br />

Fin Material<br />

<strong>Indoor</strong><br />

Fin Type<br />

Heat<br />

Row x Stage x FPI<br />

Exchanger<br />

Size (W x H x L) mm<br />

Pre coated<br />

Slit Fin<br />

2 x 15 x 19<br />

610 x 315 x 25.4<br />

Fin Material<br />

<strong>Outdoor</strong> Fin Type<br />

Heat Row x Stage x FPI<br />

Exchanger<br />

Size (W x H x D) mm<br />

Pre coated<br />

Slit Fin<br />

2 x 24 x 17<br />

703x 504 x 18.19<br />

Piping<br />

Air Filter<br />

Material<br />

Type<br />

P.P.HONEY COMB<br />

One-touch<br />

Power Supply <strong>Indoor</strong><br />

Power Supply Cord A 16A<br />

Thermostat -<br />

Protection Device -<br />

TEMPERATURE (°C )<br />

<strong>Indoor</strong> Operation Range<br />

<strong>Outdoor</strong> Operation Range<br />

COOLING HEATING<br />

DRY BULB WET BULB DRY BULB WET BULB<br />

Maximum 32 23 30 -<br />

Minimum 16 11 16 -<br />

Maximum 43 26 24 18<br />

Minimum 16 11 -5 -6<br />

1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19°C Wet Bulb (66.2°F Wet<br />

Bulb) and outdoor air temperature of 35°C Dry Bulb (95.0°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).<br />

2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor ai r temperature<br />

of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42 .8°F Wet Bulb).<br />

3. Specifications are subjected to change without prior notice for further improvement.<br />

8


3. Features<br />

• Inverter Technology<br />

o Wider output power range<br />

o Energy saving<br />

o Quick Cooling<br />

o More precise temperature control<br />

• Long Installation Piping<br />

o <strong>CS</strong>/CU-RE9/12/15NKE, long piping up to 15 meters.<br />

• Easy to use remote control<br />

• Quality Improvement<br />

o Random auto restart after power failure for safety restart operation<br />

o Gas leakage protection<br />

o Prevent compressor reverse cycle<br />

o Inner protector to protect compressor<br />

• Operation Improvement<br />

o Quiet mode to reduce the indoor unit operating sound<br />

o Powerful mode to reach the desired room temperature quickly<br />

o 12-hour timer<br />

• Serviceability Improvement<br />

o Breakdown Self Diagnosis Function.<br />

• ANTI-BACTERIAL FILTER supplied..<br />

9


4. Location of Controls and Components<br />

4.1 <strong>Indoor</strong> <strong>Unit</strong><br />

Vertical airflow<br />

direction louver<br />

4.2 <strong>Outdoor</strong> <strong>Unit</strong><br />

Air inlet(side)<br />

Air Filter<br />

4.3 Remote Control<br />

OFF/ON<br />

Fan speed<br />

selection<br />

Receiver<br />

Horizontal airflow<br />

direction louver<br />

Air inlet(rear)<br />

Air outlet<br />

� For normal operation, the ERROR RESET button is not in use.<br />

� Press RESET button to restore the remote control’s default setting.<br />

10<br />

Front Panel<br />

Transmitter<br />

Timer setting<br />

INDICATOR<br />

Temperature setting<br />

Airflow direction<br />

adjustment<br />

POWER GREEN<br />

TIMER ORANGE<br />

QUIET GREEN<br />

POWERFUL RED


5. Dimensions<br />

5.1 <strong>Indoor</strong> <strong>Unit</strong><br />

11<br />

<strong>Unit</strong>:mm


5.2 <strong>Outdoor</strong> <strong>Unit</strong><br />

CU-<strong>RE9NKE</strong><br />

<strong>Unit</strong>: mm<br />

CU-<strong>RE12NKE</strong>, CU-<strong>RE15NKE</strong><br />

12


6. Refrigeration Cycle Diagram<br />

<strong>CS</strong>/CU-<strong>RE9NKE</strong>, <strong>CS</strong>/CU- <strong>RE12NKE</strong>, CU/CU-<strong>RE15NKE</strong><br />

13<br />

COOLING<br />

HEATING


7. Block Diagram<br />

<strong>CS</strong>/CU-<strong>RE9NKE</strong><br />

14<br />

<strong>CS</strong>/CU-<strong>RE12NKE</strong>


15<br />

<strong>CS</strong>/CU-<strong>RE15NKE</strong>


8. Wiring Diagram<br />

<strong>CS</strong>/CU-<strong>RE9NKE</strong><br />

16


<strong>CS</strong>/CU-<strong>RE12NKE</strong><br />

17


<strong>CS</strong>/CU-<strong>RE15NKE</strong><br />

18


9. Printed Circuit Board<br />

9.1 <strong>Indoor</strong> <strong>Unit</strong><br />

9.1.1 Main Printed Circuit Board<br />

TOP VIEW<br />

BOTTOM VIEW<br />

19


9.1.2 Indicator & receiver<br />

TOP VIEW<br />

BOTTOM VIEW<br />

20


9.2 <strong>Outdoor</strong> <strong>Unit</strong><br />

9.2.1 CU-<strong>RE9NKE</strong><br />

TOP VIEW<br />

BOTTOM VIEW<br />

21


CU-<strong>RE12NKE</strong><br />

TOP VIEW<br />

BUTTOM VIEW<br />

22


CU-<strong>RE15NKE</strong><br />

TOP VIEW<br />

BUTTOM VIEW<br />

23


10. Installation Instruction<br />

10.1 Select the Best Location<br />

10.1.1 <strong>Indoor</strong> <strong>Unit</strong><br />

• There should not be any heat source or steam near<br />

the unit.<br />

• There should not be any obstacles blocking the air<br />

circulation.<br />

• A place where air circulation in the room is good.<br />

• A place where drainage can be easily done.<br />

• A place where noise prevention is taken into consideration.<br />

• Do not install the unit near the door way.<br />

• Ensure the spaces indicated by arrows from the wall, ceiling,<br />

fence or other obstacles.<br />

• Recommended installation height for indoor unit shall be at<br />

least 2.5m.<br />

10.1.2 <strong>Outdoor</strong> <strong>Unit</strong><br />

• If an awning is built over the unit to prevent direct sunlight or<br />

rain, be careful that heat radiation from the condenser is not<br />

obstructed.<br />

• There should not be any animal or plant which could be<br />

affected by hot air discharged.<br />

• Keep the spaces indicated by arrows from wall, ceiling, fence<br />

or other obstacles.<br />

• Do not place any obstacles which may cause a short circuit of<br />

the discharged air.<br />

• If piping length is over the rated length, additional refrigerant<br />

should be added as shown in the table below:<br />

Model Piping size Rated Max Min Max Additio- Piping<br />

Gas Liquid Length Elev- Piping Piping nal length for<br />

mm mm (m) ation Length Length Refriger add<br />

(inch) (inch) (m) (m) (m) ant<br />

(g/m)<br />

gas(m)<br />

<strong>RE9NKE</strong> 9.52 6.35 5 5 3 15 20 7<br />

(3/8”) (1/4")<br />

<strong>RE12NKE</strong> 9.52 6.35 5 5 3 15 20 7<br />

(3/8”) (1/4”)<br />

<strong>RE15NKE</strong> 12.7 6.35 5 5 3 15 20 7<br />

(1/2”) (1/4”)<br />

Example: If the unit is installed at a 10m distance, the quantity of<br />

additional refrigerant should be 60 g. …… (10-7) m x 20g/m = 60 g<br />

24<br />

11.1.3 <strong>Indoor</strong>/<strong>Outdoor</strong> <strong>Unit</strong><br />

*This illustration is for explanation purposes only.<br />

The indoor unit will actually face a different way.


10.2 <strong>Indoor</strong> <strong>Unit</strong><br />

10.2.1 How to Fix Installation Plate<br />

The mounting wall is strong and solid enough to prevent it from the vibration.<br />

The centre of installation plate should be at more<br />

than 450 mm at right and left of the wall.<br />

The distance from installation plate edge to<br />

ceiling should more than 175mm.<br />

From installation plate left edge to unit’s left side<br />

is 135 mm.<br />

From installation plate right edge to unit’s right<br />

side is 165 mm.<br />

○B : For left side piping, piping connection for liquid should be about 155 mm from this line.<br />

: For left side piping, piping connection for gas should be about 185 mm from this line.<br />

1 Mount the installation plate on the wall with 5 screws or more. (If mounting the unit on the wall, consider<br />

using anchor bolts.) Always mount the installation plate horizontally by aligning the marking-off line with<br />

the thread and using a level gauge.<br />

2 Drill the piping plate hole with ø70 mm hole-core drill.<br />

� Put measuring tape at position as shown in the diagram above. The hole centre is<br />

obtained by measuring the distance namely 115 mm and 120 mm for left and right hole<br />

respectively.<br />

� Drill the piping plate hole at either the right or left and the hole should be slightly slanted<br />

to the outdoor side.<br />

10.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping<br />

1 Insert the piping sleeve to the hole.<br />

2 Fix the busing to the sleeve.<br />

3 Cut the sleeve until it extrudes about 15mm from the wall<br />

Caution<br />

When the wall is hollow, please be sure to use the sleeve for tube<br />

ass’y to prevent dangers caused by mice biting the connecting<br />

cable.<br />

4 Finish by sealing the sleeve with putty or caulking compound at the<br />

final stage.<br />

25<br />

Wall<br />

<strong>Indoor</strong> <strong>Outdoor</strong><br />

Sleeve for<br />

tube ass’y<br />

Ø 70 through hole<br />

15 mm<br />

Approx. 5 - 7 mm<br />

Bushing for tube ass’y<br />

Putty or caulking compound


10.2.3 <strong>Indoor</strong> <strong>Unit</strong> Installation<br />

26


10.2.4 Connect the Cable to the <strong>Indoor</strong> <strong>Unit</strong><br />

1 The inside and outside connecting cable can be connected without removing the front grille.<br />

2 Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4x<br />

1.5mm 2 flexible cords, type designation 245 IEC 57 or heavier cord.<br />

� Ensure the color of wires of outdoor unit and the terminal numbers are the same to the indoor’s<br />

respectively.<br />

� Earth lead wire shall be longer than the other lead wires as shown in the figure for the electrical safety<br />

in case of the slipping out of the cord from the anchorage.<br />

� Secure the cable onto the board with the holder (clamper).<br />

3 Wire stripping and connecting requirement.<br />

10.3 <strong>Outdoor</strong> <strong>Unit</strong><br />

10.3.1 Install the <strong>Outdoor</strong> <strong>Unit</strong><br />

• After selecting the best location, start installation according to indoor/outdoor unit installation diagram.<br />

1 Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10 mm).<br />

2 When installing at roof, please consider strong wind and earthquake.<br />

Please fasten the installation stand firmly with bolt or nails.<br />

<strong>Unit</strong>: mm<br />

Model A B C D<br />

<strong>RE9NKE</strong> 474 130.4 16.6 307.9<br />

<strong>RE12NKE</strong> 570 103.7 13.4 320<br />

<strong>RE15NKE</strong> 570 103.7 13.4 320<br />

10.3.2 Connecting the Piping<br />

10.3.2.1 Connecting the piping to indoor unit<br />

Please make flare after inserting flare nut (locate at joint portion, of tube assembly) onto the copper pipe. (In case of<br />

using long piping)<br />

Connect the piping<br />

• Align the center of piping and sufficiently tighten the flare nut with fingers.<br />

• Further tighten the flare nut with torque wrench in specified torque as stated in the table.<br />

Spann<br />

er<br />

or<br />

Wrenc<br />

h<br />

Torq<br />

ue<br />

wrenc<br />

h<br />

Caution : Do not over tighten, over<br />

tightening cause gas leakage<br />

Piping size Torque<br />

6.35mm (1/4”) 18 N• m (1.8kgf•m)<br />

9.52mm (3/8") 42 N• m (4.2kgf•m)<br />

12.70mm (1/2") 55 N• m (5.5kgf•m)<br />

Connecting the piping to outdoor unit<br />

Decide piping length and then cut by using pipe cutter. Remove burrs from cut edge. Make flare after inserting the<br />

flare nut (locate at valve) onto the copper pipe. Align center of piping to valves and then tighten with torque wrench to<br />

the specified torque as stated in the table.<br />

27


10.3.2.2 Cutting and flaring the piping<br />

1 Please cut using pipe cutter and then remove the burrs.<br />

2 Remove the burrs by using reamer. If burrs are not removed, gas leakage may be caused. Turn the piping<br />

end down to avoid the metal powder entering the pipe.<br />

3 Please make flare after inserting the flare nut onto the copper pipes.<br />

10.3.3 Evacuation of the equipment<br />

When installing an air conditioner, be sure to evacuate the air inside the indoor unit and pipes in the follwing<br />

procidure.<br />

1 Connect a charging hose with a push pin to the low side of a charging set and the service port at the 3-way<br />

valve.<br />

� Be sure to connect the end of charging hose with the push pin to the service port.<br />

� The size of charging hose fitting should be 1/2 UNF, 20 threads.<br />

2 Connect the center hose of the charging set to a vacuum pump with check valve, or vacuum pump and<br />

vacuum pump adaptor.<br />

3 Turn on the power switch of the vacuum pump and make sure that the needle in the gauge moves from 0<br />

cmHg (0 Mpa) to –76 cmHg (-0.1 Mpa). Then evacuate the air approximately ten minutes.<br />

4 Close the Low side valve of the charging set and turn off the vacuum pump. Make sure that the needle in the<br />

gauge does not move after approximately five minutes.<br />

Note: BE SURE TO FOLLOW THIS PROCEDURE IN ORDER TO AVOID REFRIGEANT GAS LEAKAG<br />

5 Disconnect the charging horse from the vacuum pump and from the service port of the 3-way valve.<br />

6 Tighten the service port caps of the 3-way valve at a torque of 18 N.m with a torque wrench.<br />

7 Remove the valve caps of both of the 2-way valve and 3-way valve. Position both of the valves to “OPEN”<br />

using a hexagonal wrench (4mm).<br />

8 Mount valve caps onto the 2-way and the 3-way valve.<br />

� Be sure to check for gas leakage.<br />

CAUTION:<br />

● If gauge needle does not move from 0 cmHg (0 MPa) to -76 cmHg (-0.1 MPa), in step 3 above take the following<br />

measure:<br />

● If the leak stops when the piping connections are tightened further, continue working from step 3.<br />

● If the leak does not stop when the connections are retightened, repair the location of leak.<br />

● Do not release refrigerant during piping work for installation and reinstallation. Take care of the liquid refrigerant,<br />

it may cause frostbite.<br />

28


10.3.4 Connect the cable to the <strong>Outdoor</strong> <strong>Unit</strong><br />

1 Remove the control board cover from the unit by loosening the screw.<br />

2 Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4x<br />

1.5mm 2 flexible cords, type designation 245 IEC 57 or heavier cord.<br />

3 Secure the cable onto the control board with the holder (clamper).<br />

4 Attach the control board cover back to the original position with the screw.<br />

5 For wiring stripping and connection requirement, refer to instruction 10.2.4 of indoor unit.<br />

10.3.5 Pipe Insulation<br />

1 Please carry out insulation at pipe connection portion as mentioned in <strong>Indoor</strong>/<strong>Outdoor</strong> <strong>Unit</strong> Installation<br />

Diagram. Please warp the insulated piping end to prevent water from going inside the piping.<br />

2 If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by<br />

using POLY-E-FOAM with thickness 6mm or above.<br />

29


11. Service Mode<br />

11.1 Auto OFF/ON Button<br />

Auto OFF/ON<br />

Button Pressed<br />

1. AUTO OPERATION MODE<br />

Once the Auto OFF/ON button is slightly pressed, the unit will immediately operate in Auto operation. This<br />

operation can be used to operate air conditioner with limited function if remote control is misplaced or<br />

malfunction.<br />

2. TEST RUN OPERATION( FOR PUMP DOWN/ SERVICING PURPOSE)<br />

Press the button continuously for approximate 5 second and then release. A “beep” sound will be heard to<br />

identify the starting of TEST RUN OPERATION.<br />

3. HEATING OPERATION<br />

A) Within 5 minutes after TEST RUN operation starting, press the button again for more than 5 seconds until 2<br />

“beep” sounds are heard, the unit will operate in heating mode.<br />

B) Pressed the button continuously for approximate 8 second and then released. 2 “beep” sounds will be<br />

heard to identify the starting of HEATING operation.<br />

4. DIFFERENT CONTROLLING SETTING.<br />

Press the button continuously for approximate 11 until 3 “beep” sounds are heard and together with the signal<br />

from remote controller, the unit can be changed to different controlling setting.<br />

For transmission code selection method, please refer to “Select Remote Control Transmission Code”<br />

5. INDIVIDUAL COUNTER-ACTION<br />

When the switch is continuously pressed between 16 to 21 seconds, either H14 error detection selection mode or<br />

remote controller’s signal receiving sound can be cancelled or turned on.<br />

11.2 Select Remote Control Transmission Code<br />

� There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor PCB.<br />

The indoor unit will only operate when received signal with same transmission code from remote control. This<br />

could prevent signal interference when there are 2 or more indoor units installed near by together.<br />

� To Change the code of remote controller, following table I to join or cut jumper wire on the remote controller and<br />

setting with "Forced operation button". Four codes (A, B, C, D) can be selected. Taking code "B" for example,<br />

the process below should be follow.<br />

1. Press the "Auto OFF/ON” button on the indoor unit for approximate 11 seconds until 3 "Beep’s signal receiving<br />

sounds are heard.<br />

2. Within 5 minutes, gently press the "ERROR RESET" button on the remote control towards the indoor unit.<br />

One "Beep" sound is heard.<br />

3. Within 60 seconds, press any button on the remote control, the frequency of which was set as "B". Setting is<br />

completed after a "Beep" sound is heard. The corresponding signal sent by remote control "B" will be received<br />

by this indoor unit.<br />

Table 1<br />

Remote control J2 J3<br />

A(STANDARD) SHORT OPEN<br />

B OPEN OPEN<br />

C SHORT SHORT<br />

D OPEN SHORT<br />

30


11.3 Operate and Display of Remote Control<br />

11.3.1 Original setting<br />

11.3.2 Mode selecting button<br />

AUTO, HEAT, COOL, DRY can be selected by pressing “MODE” button. Initial display of LCD is as follow<br />

*Keeping the button depressed continuously, the operation mode will change in the following order in turn<br />

AUTO—HEAT—COOL—DRY--AUTO<br />

11.3.3 Temperature adjusting button<br />

Temperature adjusting range is between 16 ℃~30 ℃<br />

11.3.4 Fan speed button<br />

There are 5 speed levels can be selected. The display on the remote controller changes as follows by pressing the AIR SWING<br />

button.<br />

11.3.5 AIR SWING button<br />

To adjust vertical airflow directions by pressing AIR SWING button (5 options)<br />

11.3.6 QUIET AND POWERFULL button<br />

Start Quiet operation: Press QUIET button until “QUIET” displaying on remote control display to identify Quiet mode<br />

operating.<br />

Start POWERFUL operation: Press POWERFUL button until “POWERUL” displays on remote control display to<br />

identify Powerful mode operating.<br />

Switch Quiet/Powerful operation to normal operation: Press QUIET or POWERFUL button until “QUIET” or<br />

“POWERFUL” on remote control display disappear, which identifies the unit returns to normal operation.<br />

Note: QUIET and POWERFUL operation can not be active simultaneously.<br />

31


11.3.7 Timer setting button<br />

There are 4 types of timer setting by pressing Timer setting button: ON-TIMER, OFF-TIMER, ON-OFF TIMER, OFF-<br />

ON TIMER.<br />

1) SELECT button<br />

� When the air conditioner is ON, OFF-TIMER or OFF-ON TIMER can be selected by pressing SELECT<br />

button.<br />

� When the air conditioner is turned off, ON-TIMER or ON-OFF-TIMER can be selected.<br />

2) Button A and B<br />

Pressing button A can change the time for ON-TIMER and OFF-TIMER, off time for OFF-ON Timer, on time for<br />

ON-OFF TIMER; Pressing button B can change the on time for OFF-ON Timer and off time for ON-OFF Timer setting.<br />

3) SET/CANCEL button.<br />

Pressing the button to set or cancel the set timer during the timer setting or activate the previous timer setting. After the<br />

timer setting is determined, “ON” or “OFF” will stop flashing. If the timer setting is cancelled, “ON” or “OFF” will disappear<br />

on the remote control display.<br />

NOTE:<br />

� OFF Timer and OFF- ON Timer can only be set during the operation;<br />

� Timer setting can operate only once.<br />

� If the OFF/ON button on the remote control or the AUTO Switch on the indoor unit is pressed, the timer setting<br />

will be cancelled.<br />

� If Auto Restart Control occurs, timer setting will be cancelled.<br />

� During the operation, if the ON Timer or ON-OFF Timer is set, the operation will be stopped.<br />

11.3.8 About Cursor Key Which Points To “OFF” On Remote Control<br />

When the ON/OFF button on the remote control is pressed, the cursor key which points to “OFF” will appear or disappear to<br />

indicate the ON/OFF status of the air conditioner.<br />

PRESS “OFF/ON”<br />

BUTTONSS<br />

For some reason (Ex. The signal of the remote control does not reach the signal receiver of the indoor unit.), the display of the<br />

remote control will not correspond with the actual ON/OFF status of the indoor unit:<br />

1. The air conditioner is running but the cursor key which points to “OFF” appears. The air conditioner can be stopped with<br />

any button (Except for “ON/OFF”, “TIMER A”,”TIMER B”,”SELECT”) pressed.<br />

2. The air conditioner is on standby, but the cursor key which points to “OFF” disappears. The air conditioner can be started<br />

with any button (Except for “ON/OFF”, “TIMER A”,”TIMER B”,”SELECT”) pressed.<br />

32


12. Operation Control<br />

12.1 Basic Function<br />

12.1.1 Internal Setting Temperature<br />

Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting<br />

processes. These shifting processes are depending on the air conditioner settings and the operation environment.<br />

The final shifted value will be used as internal setting temperature and it is updated continuously whenever the<br />

electrical power is supplied to the unit.<br />

12.1.2 Cooling Operation<br />

12.1.2.1 Thermostat control<br />

• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature < -1.5℃<br />

• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature ><br />

Compressor OFF point.<br />

12.1.3 Soft Dry Operation<br />

12.1.3.1 Thermostat control (The same as Cooling mode)<br />

12.1.4 Heating operation<br />

12.1.4.1 Thermostat control<br />

• Compressor is OFF when Intake Air Temperature - Internal Setting Temperature > +2.0℃<br />

• Compressor is ON after waiting for 3 minutes, if the Intake Air Temperature - Internal Setting Temperature<<br />

Compressor OFF point.<br />

12.1.5 Automatic Operation<br />

• Once AUTO mode is selected, operation mode is determined by set temperature of remote control and indoor<br />

intake temperature.<br />

1st judgment<br />

JUDGE CONDITION REFERANCE MODE<br />

If indoor intake temp – Remote control<br />

temp setting ≥ +2<br />

Remote Control Setting Temp. (16℃~30℃)<br />

Auto operation Mode Shifting<br />

If -2 ≤ indoor intake temp. – Remote<br />

control Temp. setting ≤ +2<br />

If indoor intake temp. – Remote control<br />

temp. setting < -2<br />

Setting Temperature Limit Checking( Min:16 ℃; Max.:30℃)<br />

<strong>Outdoor</strong> Air Temperature Shifting<br />

Setting Temperature Limit Checking( Min:16 ℃; Max.:33℃)<br />

Internal Setting Temperature<br />

Cool mode<br />

Dry mode<br />

Heat mode<br />

33


2nd & following judgment (every 15 minutes after 1st judgment)<br />

JUDGE CONDITION REFERANCE MODE<br />

If indoor intake temp – Remote control temp<br />

setting ≥ +3<br />

If -2 ≤ indoor intake temp. – Remote control<br />

Temp. setting < +3<br />

If indoor intake temp. – Remote control<br />

temp. setting < -2<br />

12.2 <strong>Indoor</strong> Fan Motor Operation<br />

34<br />

� Cool mode if previously is Cool /<br />

Heat mode<br />

� Dry mode if previously is Dry mode<br />

Maintain current mode<br />

Heat mode<br />

Basic Rotation Speed<br />

i. Manual Fan speed<br />

Fan motor’s number of rotation is determined according to remote control setting.<br />

Model<br />

Remote control<br />

Tab<br />

O<br />

Hi<br />

O<br />

Me+<br />

O<br />

Me<br />

O<br />

Me-<br />

O<br />

Lo<br />

QUIET<br />

QLo<br />

<strong>CS</strong>-<strong>RE9NKE</strong><br />

COOLING(rpm)<br />

HEATING(rpm)<br />

1150<br />

1040<br />

1030<br />

890<br />

920<br />

830<br />

810<br />

770<br />

700<br />

710<br />

600<br />

650<br />

<strong>CS</strong>-<strong>RE12NKE</strong><br />

COOLING(rpm)<br />

HEATING(rpm)<br />

1150<br />

1150<br />

1060<br />

1010<br />

970<br />

950<br />

880<br />

890<br />

790<br />

830<br />

620<br />

680<br />

<strong>CS</strong>-<strong>RE15NKE</strong><br />

COOLING(rpm)<br />

HEATING(rpm)<br />

1320<br />

1300<br />

1160<br />

1140<br />

1040<br />

1060<br />

920<br />

980<br />

800<br />

900<br />

730<br />

740<br />

ii. Auto Fan Speed (Cooling, Soft Dry Mode)<br />

According to room temperature and setting temperature, indoor fan speed is determined automatically.<br />

The indoor fan will operate according to pattern below.<br />

Fan speed<br />

Higher<br />

Medium<br />

Lower<br />

Intake temp.- setting temp.<br />

Intake temp.- setting temp.<br />

A b c d e f g h a b<br />

B. Feedback control<br />

• Immediately after the fan motor started, feedback control is performed once every second.<br />

• During fan motor on, if fan motor feedback 2550 rpm or < 50 rpm continue for 10 seconds, then fan motor error<br />

counter increases, fan motor then stops and restarts. If the fan motor counter becomes 7 times, then H19 - fan motor<br />

error is detected. Operation stops and cannot on back.<br />

12.3 <strong>Outdoor</strong> Fan Motor Operation<br />

HEAT<br />

<strong>Outdoor</strong> fan motor is operated with one fan speed only. It starts when compressor starts operation and it stops 30<br />

seconds after compressor stops operation.<br />

DRY<br />

COOL<br />

-6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6<br />

HEAT<br />

MAINTAIN<br />

CURRENT MODE<br />

COOL/DRY<br />

-6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6


Compressor<br />

<strong>Outdoor</strong> Fan<br />

ON<br />

ON<br />

30 s<br />

12.3.1 Vertical Airflow<br />

Cooling<br />

Soft dry<br />

Heating<br />

Operating Mode<br />

Auto<br />

Auto<br />

Manual<br />

Auto<br />

Manual<br />

Manual<br />

OFF<br />

OFF<br />

ON<br />

1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated<br />

above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature. When the air<br />

conditioner is stopped using remote control, the vane will shift to close position.<br />

2. Manual vertical airflow direction can be set using remote control. The angels of the vane are as stated above. When the air<br />

conditioner is stopped using remote control, the vane will shift to close position.<br />

* Above angle data is for reference only.<br />

12.3.2 Horizontal Airflow<br />

The horizontal airflow direction louvers can be adjusted manually by hand.<br />

12.3.3 Quiet operation<br />

● To provide quiet operation comparing to normal operation. The Quiet operation can be active or stop by pressing<br />

QUIET button on remote control.<br />

● Once Quiet mode is active ,the unit will continuously operate in QUIET Mode until cancel the mode by pressing<br />

QUIET button on remote control.<br />

12.3.4 Powerful operation<br />

● To cooling or heating the room faster comparing to normal operation. The POWERFUL operation can be active or<br />

stop by pressing POWERFUL button on remote control.<br />

● When powerful operation is active, the unit will continuously operate in POWERFUL mode until cancel the mode<br />

by pressing POWERFUL button on remote control. Operation details are as the fig. below.<br />

1. For cooling, soft Dry mode<br />

Normal<br />

Powerful<br />

Normal<br />

Powerful<br />

1 2 3 4 5<br />

10° 21° 31°<br />

10°-50°<br />

40° 50°<br />

35°(Beginning of POWERFUL mode) 6°<br />

10° 21° 31° 40° 50°<br />

Normal 7° 22° 35° 50° 60°<br />

Powerful 31° 40° 48° 58° 68°<br />

Normal<br />

8° 36° 7°<br />

Powerful<br />

8° 45°(Beginning of POWERFUL mode) 33° 7°<br />

35<br />

12°<br />

12°


PIPING<br />

TEMP.<br />

(COOLING)<br />

FAN SPEED<br />

( rpm)<br />

Correction<br />

Factor( ℃ )<br />

OFF<br />

2. For Heating mode:<br />

PIPING<br />

TEMP TEMP.<br />

(COOLING)<br />

(HEATING)<br />

FAN SPEED<br />

( rpm)<br />

Correction<br />

Factor( ℃ )<br />

Power Button pressed<br />

Min.5’<br />

D<br />

C<br />

B<br />

A<br />

Fast Cooling Cooling, Soft Dry<br />

Shi<br />

-1.00<br />

-1.67<br />

Power Button pressed<br />

Min.5’<br />

D<br />

C<br />

B<br />

A<br />

Shi<br />

ON<br />

1130 (Max)<br />

45 seconds<br />

20 ‘<br />

20 ‘<br />

Fast Heating1 Heating<br />

+1.00<br />

+2<br />

1270 (Max)<br />

45 seconds<br />

20 ‘<br />

-0.25<br />

36<br />

730 (Min.)<br />

ON<br />

OFF<br />

Note: The value of A, B, C, D will change according to the indoor temperature.<br />

12.3.5 Automatic Restart Control<br />

20 ‘<br />

940 (Min.)<br />

20 ‘<br />

20 ‘ +0.25 20 ‘<br />

20 ‘<br />

+0.25<br />

+0.25<br />

AUTO<br />

AUTO<br />

When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to<br />

four minutes after power supply resumes.<br />

12.3.6 Indication Panel<br />

LED POWER TIMER QUIET POWERFUL<br />

Color Green Orange GREEN RED<br />

Light ON Operation ON Timer setting ON Quiet mode ON Powerful mode ON<br />

Light OFF Operation OFF Timer setting OFF Quiet mode OFF Powerful mode OFF<br />

Note:<br />

● If POWER LED blinks, the possible operation of the unit is operating mode judgment, or ON timer<br />

sampling.<br />

● If Timer LED blinks, there is an abnormal operation occurs.<br />

12.3.7 Timer control<br />

Delay ON Timer can be set using remote controller, the unit with timer set will start operate earlier than the setting<br />

time. This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set<br />

time for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30<br />

seconds to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation


mode. From the above judgment, the decided operation will start operate earlier than the set time as shown below.<br />

Timer Signal Receiving sound During Operation.<br />

Timer Signal Receiving Sound When the Air Conditioner Stops.<br />

13. Protection control<br />

13.1 Protection Control For All Operations<br />

13.1.1 Time Delay Safety Control<br />

● The Compressor will not turn on within 3 minutes from the moment operation stops, although the unit is turned on<br />

again by pressing OFF/ON button at remote control within this period.<br />

● This control is not applicable if the power supply is cut off and on again.<br />

● This phenomenon is to balance the pressure inside the refrigerant cycle.<br />

13.1.2 30 Seconds Forced Control<br />

● Once the air conditioner is turned on, the compressor will not stop within 30 seconds in a normal operation<br />

although the intake air temperature has reached the thermo-off temperature. However, force stop by pressing the<br />

OFF/ON button at the remote control is permitted or the Auto OFF/ON button at indoor unit.<br />

● The reason for the compressor to force operation for minimum 30 seconds is to allow the refrigerant oil run in a<br />

full cycle and return back to the outdoor unit.<br />

13.1.3 Total running current control<br />

1. If the outdoor unit total running current is detected exceeding I1(A), the frequency instructed for compressor<br />

operation will be decreased.<br />

2. If the running current does not exceed I1(A) for 5 seconds, the frequency instructed will be increased.<br />

Operation mode<br />

<strong>RE9NKE</strong><br />

I1(A)<br />

<strong>RE12NKE</strong><br />

I1(A)<br />

<strong>RE15NKE</strong><br />

I1(A)<br />

Cooling/ Soft Dry /Fan A* 6.02 6.90 7.49<br />

Cooling/ Soft Dry /Fan B 5.88 6.90 7.36<br />

Cooling/Soft Dry/ Fan C 5.03 6.90 6.9<br />

Heating 5.04 6.88 8.48<br />

*The first 30 minutes of cooling operation, A will be applied.<br />

37


13.1.4 IPM (Power transistor) Protection Control.<br />

1. DC Peak Current Control<br />

● When electric current to IPM exceeds set value of 7A(for <strong>RE9NKE</strong>),15.7A(for <strong>RE12NKE</strong>), or 19.3A(for<br />

<strong>RE15NKE</strong>) the compressor will stop. It will restart after three minutes.<br />

● If the set value is exceeded again within 30 seconds, the operation will restart after one minute.<br />

● If this condition repeats continuously for seven times, all indoor and outdoor relays will be cut off.<br />

● Error code [F99] will be displayed.<br />

2. Overheating protection control<br />

When the IPM temperature rises to 120 ℃ , compressor will stop immediately.<br />

Compressor restarts after three minutes if the temperature decreases to 110℃<br />

13.1.5 Compressor Overheating Prevention Control<br />

Instructed frequency for compressor operation will be regulated compressor discharge temperature. The change of<br />

frequency is as below.<br />

<strong>RE9NKE</strong> RE12/15NKE<br />

13.1.6 Low Operation Frequency Protection Control<br />

● When the compressor operate frequency lower than 24Hz continued for 240 minutes, the operation frequency will<br />

be changed to 23Hz for 2 minutes.<br />

13.1.7 Low Operation Frequency Protection Control<br />

If all following conditions exists, the compressor will run with the frequency of 30 Hz.<br />

Models <strong>RE9NKE</strong>, <strong>RE12NKE</strong>,<strong>RE15NKE</strong><br />

Intake Air Temp. ≥30 ℃ or


<strong>Indoor</strong> piping temperature - indoor suction is under 5℃.<br />

<strong>Indoor</strong> temperature and outdoor temperature is 20 ± 2℃.<br />

Remote control setting 30℃ and Hi Fan Speed.<br />

b. Control contents<br />

• Compressor stops (and restart after 3 minutes)<br />

• If the conditions above happen 2 times within 20 minutes, the unit will:<br />

- Stop operation<br />

- Timer LED blinks and “F91” indicated<br />

13.2 Protection Control For Cooling and Soft Dry Operation<br />

13.2.1 <strong>Outdoor</strong> Air Temperature Control<br />

• The compressor operating frequency is regulated in accordance to the outdoor air temperature as shown in the<br />

diagram below.<br />

• This control will begin 1 minute after the compressor starts.<br />

• Compressor frequency will adjust base on outdoor air temperature.<br />

<strong>Outdoor</strong> air temp.( ℃) <strong>Outdoor</strong> air temp.( ℃)<br />

<strong>Outdoor</strong> air temp.( ℃)<br />

<strong>RE9NKE</strong> <strong>RE12NKE</strong> <strong>RE15NKE</strong><br />

13.2.2 Freeze Prevention Control<br />

1 .Frequency of the compressor<br />

For prevention of freezing of the indoor evaporator, the frequency of the compressor will be changed according to<br />

the indoor piping temperature.<br />

2 .<strong>Indoor</strong> Fan Control<br />

<strong>Indoor</strong> fan speed changes according to the indoor piping temperature.<br />

13.2.3 Dew Prevention Control<br />

• To prevent dew formation at indoor unit discharge area.<br />

• This control starts if all conditions continue for 20 minutes:<br />

- Operated with Cooling or Soft Dry Mode.<br />

- <strong>Outdoor</strong> air temperature is less than 34℃.<br />

• This control stopped if anyone of the following conditions is achieved:<br />

- <strong>Outdoor</strong> air temperature is over 34℃.<br />

- Intake air temperature is less than 24℃.<br />

- Operation without Cooling or Soft Dry Mode.<br />

39


13.2.4 Overload Protection For Cooling Operation<br />

The frequency for the compressor will change according to the outdoor piping temperature.<br />

13.3 <strong>Indoor</strong> Piping Air Temperature Control (Heating)<br />

13.3.1 <strong>Indoor</strong> Fan Control<br />

1. <strong>Indoor</strong> fan is controlled by the indoor piping temperature.<br />

● Manual Fan Speed<br />

Piping Temperature(℃)<br />

K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 K10 K11<br />

16 19 24 32 32 36 36 39 54 54 57 60<br />

● Auto Fan Speed<br />

2. During heating operation, the indoor fan will run at the following speed when the compressor stops.<br />

1 2 3 4 5 6 7 8<br />

Comp.<br />

ON<br />

OFF<br />

Fan speed<br />

(rpm)<br />

<strong>Outdoor</strong> pipe Temp.<br />

Control<br />

by piping<br />

temp.<br />

+15rpm/s<br />

Fixed<br />

K8<br />

K7<br />

K6<br />

<strong>RE9NKE</strong> 550 440 550 440 550 440<br />

<strong>RE12NKE</strong> 500 440 500 440 500 440<br />

<strong>RE15NKE</strong> 500 440 500 440 500 440<br />

Time<br />

_<br />

20 100 20 100 20 100<br />

(Second)<br />

3. Hot Start<br />

When the heating operation starts, the indoor fan stops and the compressor runs with a certain frequency.<br />

This is to prevent the cold airflow from blowing.<br />

If the piping temperature rises to 19 ℃, and the indoor fan speed varies with the indoor piping temperature, the hot<br />

start control is stopped.<br />

40


13.3.2 Overload Protection Control<br />

The frequency for the compressor is determined by indoor piping temperature.<br />

<strong>Indoor</strong> piping temp.<br />

<strong>Indoor</strong> piping temp. <strong>Indoor</strong> piping temp.<br />

<strong>RE9NKE</strong> <strong>RE12NKE</strong> <strong>RE15NKE</strong><br />

41


14. Troubleshooting Guide<br />

14.1 Refrigeration cycle system<br />

In order to diagnose malfunctions, make sure that there are no<br />

electrical problems before inspecting the refrigeration cycle. Such<br />

problems include insufficient insulation, problem with the power<br />

source, malfunction of a compressor and a fan. The normal outlet<br />

air temperature and pressure of the refrigeration cycle depends on<br />

various conditions, the standard values for them are shown in the<br />

table on the right.<br />

14.1.1<br />

Different in the intake<br />

and outlet<br />

air temperatures<br />

Value of electric current<br />

during operation<br />

Gas side<br />

pressure<br />

More than 8°C<br />

(15 minutes after an operation<br />

is started) at cooling mode.<br />

Above 14°C (15 minutes after<br />

an operation is started.) at<br />

heating mode<br />

Less than 8°C at the cooling mode<br />

Less than 14°C at the heating mode<br />

Lower than<br />

specified<br />

Higher than specified<br />

Cooling<br />

Mode<br />

Heating<br />

Mode<br />

High<br />

Low<br />

Low<br />

Low<br />

Low<br />

Low<br />

42<br />

Normal<br />

Dusty condenser<br />

preventing heat radiation<br />

Excessive amount<br />

of refrigerant<br />

Inefficient compressor<br />

Insufficient refrigerant<br />

Clogged strainer or<br />

capillary cube<br />

Inefficient compressor<br />

Insufficient refrigerant<br />

Clogged strainer or<br />

capillary cube<br />

Normal Pressure and Outlet Air Temperature (Standard)<br />

Gas Pressure<br />

Mpa<br />

(kg/cm 2 G)<br />

Outlet air<br />

Temperature<br />

(°C)<br />

Cooling Mode 0.9~1.2 ( 9~12) 12~16<br />

Heating Mode 2.3 ~2.9 (23~29) 36~45<br />

Condition: <strong>Indoor</strong> fan speed = High<br />

<strong>Outdoor</strong> temperature = 35°C at cooling mode and 7° C at<br />

heating mode.<br />

Compressor operates at rated frequency<br />

• Measuring the air<br />

temperature different<br />

• Measuring electric<br />

current during operation<br />

• Measuring gas side<br />

pressure


14.1.2 Relationship between the condition of the air conditioner and pressure and electric<br />

current<br />

Condition of the<br />

air conditioner Low Pressure<br />

Insufficient<br />

refrigerant<br />

(gas leakage)<br />

Clogged capillary<br />

tube or<br />

strainer<br />

Short circuit in the<br />

indoor unit<br />

Heat radiation<br />

deficiency<br />

of the outdoor unit<br />

Inefficient<br />

compression<br />

Cooling Mode Heating Mode<br />

High<br />

Pressure<br />

Electric current<br />

during<br />

operation<br />

43<br />

Low Pressure<br />

High<br />

Pressure<br />

� � � � � �<br />

� � � � � �<br />

� � � � � �<br />

� � � � � �<br />

� � � � � �<br />

Electric current<br />

during operation<br />

• Carry out the measurement of pressure, electric current, and temperature fifteen minutes after an operation is<br />

started.<br />

14.2 Breakdown Self Diagnosis Function<br />

14.2.1 About Self Diagnosis<br />

When the air-conditioner is stopped due to malfunction detected by itself, the operation can be restarted using AUTO<br />

Switch on the indoor unit. In forced operation, the frequency for compressor and fan speed can not be changed and<br />

the signal receiving sound is different.<br />

Normal Operation ON: “pep”<br />

Forced Operation ON: “pep”, “pep”, “pep”, “pep”<br />

Stop: “pep”<br />

Note: Refer to the Diagnosis Code Table for the malfunction when forced operation is not available.<br />

14.2.2 Display of Error Code<br />

1. Keeping the CHECK button on the remote controller depressed for 5 seconds, error code ranging fromH11 to H99<br />

can be displayed on the remote controller.<br />

2. The error code is changed and diagnosis signal is transmitted to the indoor unit by pressing the Temp Up button<br />

on the remote control.<br />

3. When the malfunction of the air-conditioner matches the error code on the remote control, four beeps can be heard<br />

from the indoor unit and the operation indicator will light up.<br />

4. Keep the CHECK button depressed continuously for 5 seconds to cancel the diagnosis function.


14.2.3 Error Codes Table<br />

Code Abnormality/Protection Judgment Check<br />

H00 Normal<br />

H11<br />

H14<br />

H15<br />

H16<br />

H19<br />

H23<br />

H27<br />

H28<br />

H30<br />

<strong>Indoor</strong>/<strong>Outdoor</strong> abnormal<br />

communication<br />

<strong>Indoor</strong> intake air temp sensor<br />

abnormality<br />

>1 minute after starting<br />

operation<br />

<strong>Outdoor</strong> compressor<br />

Continue for 5 sec.<br />

tempearture sensor abnormality<br />

<strong>Outdoor</strong> Current Transformer<br />

open circuit<br />

<strong>Indoor</strong> fan motor mechanism<br />

lock<br />

<strong>Indoor</strong> heat exchanger<br />

temperature A sensor<br />

abnormality<br />

<strong>Outdoor</strong> air temperature sensor<br />

abnormality<br />

-<br />

44<br />

Connecting cable,<br />

<strong>Indoor</strong>/outdoor PCB<br />

Intake air temperature<br />

sensor(defected or<br />

disconnected)<br />

Compressor tempeature<br />

sensor(defected or<br />

disconnected)<br />

Emergency<br />

Operation<br />

- <strong>Outdoor</strong> PCB, IPM module ×<br />

- <strong>Indoor</strong> PCB, fan motor ×<br />

Continue for 5 sec.<br />

Continue for 5 sec.<br />

<strong>Outdoor</strong> heat exchanger<br />

Continue for 5 sec.<br />

temperature sensor abnormality<br />

Discharge temperature sensor<br />

abnormality<br />

Continue for 5 sec.<br />

Heat exchanger<br />

temperature<br />

sensor(defected or<br />

disconnected)<br />

<strong>Outdoor</strong> temperature<br />

sensor(defected or<br />

disconnected)<br />

<strong>Outdoor</strong> heat exchanger<br />

sensor(defected<br />

disconnected)<br />

Discharge temperature<br />

sensor(defected or<br />

disconnected)<br />

<strong>Indoor</strong>/outdoor supply<br />

voltage<br />

H33<br />

Incorrect connection of<br />

<strong>Indoor</strong>/<strong>Outdoor</strong> cable<br />

-<br />

×<br />

H97 <strong>Outdoor</strong> fan motor lock Twice within 30 minutes <strong>Outdoor</strong> fan motor ×<br />

H98 <strong>Indoor</strong> high pressure protection -<br />

Air filter dirty<br />

Air circulation short circuit<br />

-<br />

H99<br />

<strong>Indoor</strong> heat exchanger antifreezing<br />

protection<br />

<strong>Indoor</strong> heat exchanger<br />

freezing<br />

Insufficient refrigerant<br />

Air filter dirty<br />

-<br />

F11<br />

Cooling/Heating cycle<br />

changeover abnormality<br />

4 times occurrence<br />

within 30 minutes<br />

4-way valve<br />

V-coil<br />

×<br />

F90 PFC control<br />

4 times occurrence<br />

within 20 minutes<br />

Voltage at PFC ×<br />

F91 Refrigeration cycle abnormality<br />

2 times occurrence<br />

within 20 minutes<br />

No refrigerant(3-way valve is<br />

closed)<br />

×<br />

F93 Compressor abnormality<br />

4 times occurrence<br />

within 20 minutes<br />

Compressor ×<br />

F95 Cool high pressure protection<br />

4 times occurrence<br />

within 20 minutes<br />

<strong>Outdoor</strong> refrigeration cycle<br />

Excessive refrigerant<br />

×<br />

F96 IPM overheating protection -<br />

Improper heat radiation<br />

IPM<br />

×<br />

F97<br />

<strong>Outdoor</strong> compressor<br />

overheating protection<br />

4 times occurrence<br />

within 20 minutes<br />

Insufficient refrigerant<br />

Compressor<br />

×<br />

F98<br />

3 times occurrence<br />

Total running current protection<br />

within 20 minutes<br />

Excess refrigerant<br />

Improper radiation<br />

×<br />

F99<br />

<strong>Outdoor</strong> Peak Current<br />

Protection Control<br />

4 times occurrcnce<br />

continuously within 30<br />

minutes<br />

<strong>Outdoor</strong> PCB<br />

IPM<br />

Compressor<br />

×<br />

○<br />

×<br />

×<br />

○<br />

○<br />

○<br />

×


15. Disassembly and Assembly Instructions<br />

WARNING<br />

High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged<br />

sufficiently before proceeding with repair work. Failure to heed this caution may result in electric shocks.<br />

Removal Procedure for Intake Grille<br />

1. Open the intake grille and pull it to the horizontal position.<br />

2. Pull up the intake grille until it falls off.<br />

Removal Procedure for Front Grille<br />

1. Remove the two caps at the discharge port (right and left) and then release the two screws on both sides.<br />

Cap<br />

2. Pull out the front grille form the unit body.<br />

Front grille<br />

45<br />

Screw


Removal Procedure for Main Electronic Controller<br />

1. After front grille is taking off, remove the cover of control board and holder, then the Main PCB can be seen.<br />

3. Drag out the supporting hook to the right side and pull up a bit the main PCB. Then release the lead wire<br />

connecting to CN-FM, CN-STM3, earth wire (Yellow/Green) on main PCB, take out the sensor from the holder on<br />

evaporator, release the CN1 connector on indicator PCB, pull out the whole electronic controller. Be sure to avoid<br />

cracking of the supporting hook.<br />

CN-FM: Fan motor connector<br />

Control board cover<br />

Supporting<br />

Hook<br />

Holder<br />

4. Remove the control board complete<br />

Loose the screws of control board complete, then the whole control board can be pulled out.<br />

Removal Procedure for Main Electronic Controller<br />

Indicator & receiver<br />

Auto OFF/ON<br />

switch CN-STM3: Air swing motor connector<br />

1. Separate the drain hose and the drain plate. 2. Pull out the discharge grille slightly.<br />

46<br />

CN-TH: Sensor connector<br />

CN1: Indicator connector<br />

Main PCB


Removal Procedure for Cross Flow Fan<br />

1. Release fixing screws on both side, disassembly the fixing board from evaporator on the left side and pull out the<br />

whole evaporator.<br />

Fixing board<br />

2. Loose the fixing screw of the cross flow fan.<br />

Fixing Screw<br />

3. After removing the bearing, indoor fan can be taken out from the left side<br />

4. Lift up the indoor fan slightly, and then pull the fan motor out.<br />

Bearing<br />

47<br />

Fan motor


16. Exploded View and Replacement Pars List<br />

16.1 <strong>Indoor</strong> <strong>Unit</strong><br />

<strong>CS</strong>-<strong>RE9NKE</strong>, <strong>CS</strong>-<strong>RE12NKE</strong>, <strong>CS</strong>-<strong>RE15NKE</strong><br />

48


NO. PART NAME QTY. <strong>CS</strong>-<strong>RE9NKE</strong> <strong>CS</strong>-<strong>RE12NKE</strong> <strong>CS</strong>-<strong>RE15NKE</strong> REMARK<br />

1 CHASSIS COMPLETE 1 CWD50C1644 CWD50C1644 CWD50C1738<br />

2 FAN MOTOR(DC,280-340V,30W) 1 ARW7648AC ARW7648AC ARW7648AC<br />

3 CROSS FLOW FAN COMPLETE 1 CWH02C1095 CWH02C1095 CWH02C1095<br />

4 BEARING ASS'Y 1 CWH64K1008 CWH64K1008 CWH64K1008<br />

5 EVAPORATOR 1 CWB30C3981 CWB30C3977 CWB30C3978<br />

6 AUXILIARY TUBE ASS'Y 1 CWT01C5455 CWT01C5455 CWT01C5456<br />

7 DRAIN PLUG 1 CWH521096 CWH521096 CWH521096<br />

8 DISCHARGE GRILLE COMPLETE 1 CWE20C3276 CWE20C3276 CWE20C3276<br />

9<br />

AIR SWING<br />

MOTOR(DC,12V,200OHM)<br />

1 CWA981292 CWA981292 CWA981292<br />

10 HORIZONTAL AIR FLOW VANE (L) 1 CWE24C1292 CWE24C1292 CWE24C1292<br />

11 HORIZONTAL AIR FLOW VANE (R) 1 CWE24C1291 CWE24C1291 CWE24C1291<br />

12 VERTICAL AIR FLOW VANE 1 CWE24C1413 CWE24C1413 CWE24C1413<br />

13 CONTROL BOX COMPLETE 1 CWH14C9275 CWH14C9276 CWH14C9279<br />

14 CONTROL BOARD CASING 1 CWH102487 CWH102487 CWH102487<br />

15 PARTICULAR PIECE 1 CWD933089 CWD933089 CWD933089<br />

16 TERMINAL BOARD COMPLETE 1 CWA28C2546 CWA28C2547 CWA28C2546<br />

17<br />

POWER SUPPLY CORD<br />

COMPLETE<br />

1 CWA20C3068 CWA20C3068 CWA20C3074<br />

18 MAIN PCB 1 CWA73C5921 CWA73C5922 CWA73C5923<br />

19 SENSOR 1 CWA50C2883 CWA50C2883 CWA50C2883<br />

20 INDICATOR HOLDER 1 CWD933546 CWD933546 CWD933546<br />

21 INDICATOR PCB 1 CWA746860 CWA746860 CWA746860<br />

22 CONTROL BOARD TOP COVER 1 CWH131523 CWH131523 CWH131523<br />

23 CONTROL BOARD BACK COVER 1 CWH131526 CWH131526 CWH131526<br />

24 REMOTE CONTROL 1 CWA75C3755 CWA75C3755 CWA75C3755<br />

25 FRONT GRILLE COMPLETE 1 CWE11C5307 CWE11C5307 CWE11C5307<br />

26 INTAKE GRILLE 1 CWE22K1594 CWE22K1594 CWE22K1594<br />

27 GRILLE DOOR 1 CWE14C1092 CWE14C1092 CWE14C1092<br />

28 AIR FILTER 2 CWD001339 CWD001339 CWD001339<br />

29 ANTI-BACTERIAL FILTER 1 CWD001280 CWD001280 CWD001280<br />

30 SCREW-FRONT GRILLE 2 XTT4+16CFJ XTT4+16CFJ XTT4+16CFJ<br />

31 CAP-FRONT GRILLE 2 CWH521236A CWH521236A CWH521236A<br />

32 DRAIN HOSE 1 CWH851136 CWH851136 CWH851136<br />

33 OPERATING INSTRUTIONS 1 CWF568363 CWF568363 CWF568363<br />

34 INSTALLATION INSTRUCTION 1 CWF615218 CWF615218 CWF615218<br />

35 INSTALLATION INSTRUCTION 1 CWF615219 CWF615219 CWF615219<br />

36 INSTALLATION INSTRUCTION 1 CWF615220 CWF615220 CWF615220<br />

37<br />

(Note)<br />

INSTALLATION PLATE 1 CWH361133 CWH361133 CWH361133<br />

• All parts are supplied from PAPAGZ, China<br />

49


16.2 <strong>Outdoor</strong> <strong>Unit</strong><br />

CU-<strong>RE9NKE</strong><br />

50


NO. PART NAME QTY. CU-<strong>RE9NKE</strong> REMARK<br />

1 CHASSIS ASS'Y 1 CWD52K1299A<br />

2 FAN MOTOR BRACKET 1 CWD541177<br />

3 SCREW-FAN MOTOR BRACKET 2 CWH551148A<br />

4 FAN MOTOR(AC,220-230V,20W) 1 CWA951842<br />

5 SCREW-FAN MOTOR MOUNT 4 CWH551148A<br />

6 PROPELLER FAN ASS'Y 1 CWH03K1069<br />

7 NUT-PROPELLER FAN 1 CWH561036J<br />

8 COMPRESSOR 1 CWB092606<br />

9 ANTI-VIBRATION BUSHING 3 CWH501022<br />

10 NUT-COMPRESSOR MOUNT 3 CWH561047A<br />

11 CONDENSER 1 CWB32C3238<br />

12 HOLDER COUPLING ASS'Y 1 CWH351191A<br />

13 4-WAY VALVE 1 CWB001063<br />

14 2-WAY VALVE 1 CWB021531<br />

15 3-WAY VALVE 1 CWB011645<br />

16 STRAINER 1 CWB111026<br />

17 TERMINAL COVER 1 CWH171041<br />

18 SOUND PROOF BOARD 1 CWH15K1048<br />

19 SOUND PROOF MATERIAL 1 CWG302731<br />

20 SOUND PROOF MATERIAL 1 CWG302732<br />

21 TUBE (NOISE SUPPRESSOR) 1 CWB141023<br />

22 REACTOR 1 G0C193J00014<br />

23 CONTROL BOX COMPLETE 1 CWH14C9273<br />

24 TERMINAL BOARD ASS'Y 1 CWA28K1248<br />

25 SENSOR COMPLETE(COMP.) 1 CWA50C2848<br />

26 SENSOR COMPLETE(PIPING) 1 CWA50C2835<br />

27 TUBE ASS'Y(CAPILLARY) 1 CWT01C6046<br />

28 V-COIL COMPLETE 1 CWA43C2356<br />

29 TOP PLATE 1 CWE03K1052A<br />

30 CABINET FRONT PLATE 1 CWE06C1386<br />

31 CABINET SIDE PLATE (R) 1 CWE04C1371<br />

32 CABINET SIDE PLATE (L) 1 CWE04K1155A<br />

33 CONTROL BOARD COVER 1 CWH131544A<br />

34 DISCHARGE GRILLE 1 CWE201207<br />

35 DRAIN ELBOW 1 CWT201212<br />

36 SCREW-TOP PLATE 2 CWH551295<br />

(Note)<br />

All parts are supplied from PAPAGZ, China<br />

51


CU-<strong>RE12NKE</strong>,CU-<strong>RE15NKE</strong><br />

52


NO. PART NAME QTY. CU-<strong>RE12NKE</strong> CU-<strong>RE15NKE</strong> REMARK<br />

1 CHASSIS ASS'Y 1 CWD52K1303A CWD52K1303A<br />

2 FAN MOTOR BRACKET 1 CWD541146 CWD541146<br />

3<br />

SCREW-FAN MOTOR<br />

BRACKET<br />

2 CWH551148A CWH551148A<br />

FAN MOTOR(AC,230,40W) 1 CWA951766 -<br />

4 FAN MOTOR(DC,280-<br />

340V,40W)<br />

1 - L6CAYYYL0018<br />

5 SCREW-FAN MOTOR MOUNT 4 CWH551148A CWH551148A<br />

6 PROPELLER FAN ASS'Y 1 CWH03K1059 CWH03K1064<br />

7 NUT-PROPELLER FAN 1 CWH561036J CWH561034J<br />

8 COMPRESSOR 1 CWB092605 CWB092574<br />

9 ANTI-VIBRATION BUSHING 3 CWH501022 CWH501022<br />

10 NUT-COMPRESSOR MOUNT 3 CWH561047A CWH561047A<br />

11 CONDENSER 1 CWB32C3511A CWB32C3529A<br />

12 HOLDER COUPLING ASS'Y 1 CWH351191A CWH351191A<br />

13 4-WAY VALVE 1 CWB001063 CWB001063<br />

14 2-WAY VALVE 1 CWB021531 CWB021531<br />

15 3-WAY VALVE 1 CWB011645 CWB011643<br />

16 STRAINER 1 CWB111026 CWB111026<br />

17 TERMINAL COVER 1 CWH171048 CWH171048<br />

18 SOUND PROOF BOARD 1 CWH15K1034 CWH15K1034<br />

19 SOUND PROOF MATERIAL 1 CWG302703 CWG302609<br />

20 SOUND PROOF MATERIAL 1 CWG302605 CWG302605<br />

21 SOUND PROOF MATERIAL 1 CWG302693 -<br />

22 TUBE (NOISE SUPPRESSOR) 1 CWB141023 CWB141023<br />

23 REACTOR 1 G0C103J00034 G0C193J00011<br />

24 CONTROL BOX COMPLETE 1 CWH14C9612 CWH14C9270<br />

25 TERMINAL BOARD ASS'Y 1 CWA28K1248 CWA28K1248<br />

26 SENSOR COMPLETE(COMP.) 1 CWA50C2834 CWA50C2897<br />

27 SENSOR COMPLETE(PIPING) 1 CWA50C2882 CWA50C2766<br />

28 TUBE ASS'Y(CAPILLARY) 1 CWT01C6071 CWT01C6092<br />

29 V-COIL COMPLETE 1 CWA43C2472 CWA43C2472<br />

30 TOP PLATE 1 CWE03K1040A CWE03K1040A<br />

31 CABINET FRONT PLATE 1 CWE06C1337 CWE06C1337<br />

32 CABINET SIDE PLATE (R) 1 CWE04C1261 CWE04C1261<br />

33 HANDLE 1 CWE16037C CWE16037C<br />

34 CONTROL BOARD COVER 1 CWH131544A CWH131544A<br />

35 DISCHARGE GRILLE 1 CWE201195 CWE201195<br />

36 DRAIN ELBOW 1 CWT201212 CWT201212<br />

37 SCREW-TOP PLATE 2 CWH551295 CWH551295<br />