Cello GSM Level Recorder Engineering Solutions - Imbema Belgium
Cello GSM Level Recorder Engineering Solutions - Imbema Belgium
Cello GSM Level Recorder Engineering Solutions - Imbema Belgium
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Cello</strong> <strong>GSM</strong> <strong>Level</strong> <strong>Recorder</strong><br />
A Universal Solution for Remote <strong>Level</strong> Monitoring<br />
The <strong>Cello</strong> <strong>GSM</strong> <strong>Level</strong> <strong>Recorder</strong> combines the<br />
Siemens Milltronics ultrasonic level sensor with<br />
the Technolog <strong>Cello</strong> <strong>GSM</strong>/SMS Data Logger.<br />
The result is a battery powered level measurement<br />
system with remote communications.<br />
Traditionally, ultrasonic sensors and <strong>GSM</strong><br />
modems have been mains powered since both<br />
devices consume significant power during<br />
operation. The <strong>Cello</strong> <strong>GSM</strong> <strong>Level</strong> <strong>Recorder</strong> utilises<br />
Technolog's power saving techniques to provide<br />
up to 5 years battery life.<br />
The system comprises two parts, the ultrasonic<br />
sensor and the <strong>GSM</strong> data logger which are<br />
connected via a 10m cable. This allows the sensor<br />
to be mounted directly above the surface of the<br />
material to be measured and the <strong>Cello</strong> to be<br />
housed in a more convenient location.<br />
The sensor houses the ultrasonic transducer and<br />
temperature sensing element. The sensor emits a<br />
series of ultrasonic pulses from the transducer.<br />
Each pulse is reflected as an echo from the<br />
material and sensed by the transducer. The echo<br />
is processed and filtering is applied to help<br />
discriminate between the true echo from the<br />
material, and false echoes. The time for the pulse<br />
to travel to the material and back is temperature<br />
compensated and then converted to distance.<br />
TECHNOLOG<br />
<strong>Engineering</strong> <strong>Solutions</strong> for the Utilities<br />
Technolog can also provide a complete installation and maintenance service<br />
TECHNOLOG<br />
The numeric values are read by the <strong>Cello</strong> and<br />
recorded in memory at predetermined intervals.<br />
Periodically, such as every day, the recorded<br />
values are transmitted by SMS (text message) to a<br />
host computer or the Internet. The usage of SMS<br />
is dependent upon several factors including the<br />
recording interval and data send frequency. The<br />
system will typically use one SMS per day. In the<br />
event that one or more measurements are outside<br />
preset parameters, the <strong>Cello</strong> will immediately<br />
send an alarm message which can be received by<br />
email, SMS or an alarm banner on the host<br />
computer.<br />
DS5P9000 Rev. A DMR: N / A
Technical Specifications<br />
Input Specifications<br />
Certification Certified Intrinsically Safe ('I.S.')<br />
For further information contact: Technolog Limited<br />
Ravenstor Road<br />
Wirksworth<br />
Matlock<br />
Derbyshire DE4 4FY<br />
United Kingdom<br />
Tel: +44 (0)1629 823611<br />
Fax: +44 (0)1629 824283<br />
E-mail: technolog@technolog.com<br />
Internet: www.technolog.com<br />
TECHNOLOG<br />
<strong>Cello</strong> I.S. Mk. 2<br />
SIRA 06ATEX2010X - EEx ia IIC T4 (Ta=-20 to +60 Deg. C.) or EEx ia IIC T3 (Ta= -20 to +60 Deg. C.)<br />
IECEx SIR 06.0003X - Ex ia IIC T4 (Ta= -20 to +60 Deg. C.) or Ex ia IIC T3 (Ta= -20 to +60 Deg. C.)<br />
CSO Monitor<br />
SIRA 06ATEX 2011X - EEx ia IIC T4 (Ta= -20 to +60 Deg. C.)<br />
IECEx SIR 06.0002X - Ex ia IIC T4 (Ta= -20 to +60 Deg. C.)<br />
Input Ultrasonic <strong>Level</strong> Measurement<br />
Range 0.25 to 3 m (liquids)<br />
Accuracy +/-0.25% F.S. (liquids)<br />
Temperature Compensation Built-in to compensate over the operating range<br />
Beam Angle 10° at -3 dB boundary<br />
General Specifications<br />
<strong>GSM</strong> Modem Frequency: 900 MHz , 1800 MHz. Integral antenna<br />
Serial Port Type: Full duplex, asynchronous<br />
Data rate: 1200, 2400, 4800, 9600 bps<br />
Memory Type: Solid state, non-volatile<br />
Size: 128K, allocatable between channels as required (max 64K/channel)<br />
Clock Type: Crystal controlled calendar clock with leap year adjustment<br />
Accuracy: 100 seconds per month maximum error over operating temperature range<br />
Synchronisation: Option to synchronise clock to <strong>GSM</strong> network<br />
Supply Type: Internally powered by a single lithium battery pack, factory exchangeable<br />
Life: Typical battery life 5 years depending on mode of use<br />
Recording Recording interval: programmable between 1 minute and 1 hour<br />
Data storage: Rotating store, or store until full<br />
Alarm Dial-Out High/low<br />
update data more frequently after an alarm<br />
Environmental Operating temperature: -20°C to +50°C<br />
Protection classification: IP68<br />
Dimensions (mm) CSO Monitor: 217(h) x 82(w) x 88(d)<br />
<strong>Cello</strong>: 191(h) x 140(w) x 150(d)<br />
DS5P9000 Rev. A DMR: N / A