Understanding Neutron Radiography Post Exam Reading VIII-Part 2a of 2A

Understanding Neutron Radiography Post Exam Reading VIII-Part 2a of 2A

Understanding Neutron Radiography Post Exam Reading VIII-Part 2a of 2A

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Understanding</strong> <strong>Neutron</strong> <strong>Radiography</strong><br />

<strong>Reading</strong> <strong>VIII</strong> <strong>Part</strong> 2(a) <strong>of</strong> 2<br />

16 th August 2016<br />

<strong>Post</strong> <strong>Exam</strong> <strong>Reading</strong><br />

Charlie Chong/ Fion Zhang


Spallation Source<br />

Charlie Chong/ Fion Zhang


Spallation Source<br />

Charlie Chong/ Fion Zhang


Spallation Source<br />

Charlie Chong/ Fion Zhang<br />

http://www.gizmodo.com.au/2014/01/27-amazing-images-from-the-depths-<strong>of</strong>-scientific-labs/


Spallation Source<br />

Charlie Chong/ Fion Zhang<br />

http://www.gizmodo.com.au/2014/01/27-amazing-images-from-the-depths-<strong>of</strong>-scientific-labs/


The Magical Book <strong>of</strong> <strong>Neutron</strong> <strong>Radiography</strong><br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


ASNT Certification Guide<br />

NDT Level III / PdM Level III<br />

NR - <strong>Neutron</strong> Radiographic Testing<br />

Length: 4 hours Questions: 135<br />

1. Principles/Theory<br />

• Nature <strong>of</strong> penetrating radiation<br />

• Interaction between penetrating radiation and matter<br />

• <strong>Neutron</strong> radiography imaging<br />

• Radiometry<br />

2. Equipment/Materials<br />

• Sources <strong>of</strong> neutrons<br />

• Radiation detectors<br />

• Non-imaging devices<br />

Charlie Chong/ Fion Zhang


3. Techniques/Calibrations<br />

• Blocking and filtering<br />

• Multifilm technique<br />

• Enlargement and projection<br />

• Stereoradiography<br />

• Triangulation methods<br />

• Autoradiography<br />

• Flash <strong>Radiography</strong><br />

• In-motion radiography<br />

• Fluoroscopy<br />

• Electron emission radiography<br />

• Micro-radiography<br />

• Laminography (tomography)<br />

• Control <strong>of</strong> diffraction effects<br />

• Panoramic exposures<br />

•Gaging<br />

• Real time imaging<br />

• Image analysis techniques<br />

Charlie Chong/ Fion Zhang


4. Interpretation/Evaluation<br />

• Image-object relationships<br />

• Material considerations<br />

• Codes, standards, and specifications<br />

5. Procedures<br />

• Imaging considerations<br />

• Film processing<br />

• Viewing <strong>of</strong> radiographs<br />

• Judging radiographic quality<br />

6. Safety and Health<br />

• Exposure hazards<br />

• Methods <strong>of</strong> controlling radiation exposure<br />

• Operation and emergency procedures<br />

Reference Catalog Number<br />

NDT Handbook, Third Edition: Volume 4,<br />

Radiographic Testing 144<br />

ASM Handbook Vol. 17, NDE and QC 105<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang<br />

Fion Zhang at Copenhagen Harbor<br />

16 th August 2016


Charlie Chong/ Fion Zhang<br />

SME- Subject Matter Expert<br />

http://cn.bing.com/videos/search?q=Walter+Lewin&FORM=HDRSC3<br />

https://www.youtube.com/channel/UCiEHVhv0SBMpP75JbzJShqw


Gamma- <strong>Radiography</strong><br />

TABLE 1. Characteristics <strong>of</strong> three isotope sources commonly used for<br />

radiography.<br />

Source<br />

T½<br />

Energy<br />

HVL<br />

HVL<br />

Specific<br />

Dose rate*<br />

Pb<br />

Fe<br />

Activity<br />

Co60<br />

5.3 year<br />

1.17, 1.33 MeV<br />

12.5mm<br />

22.1mm<br />

50 Cig -1<br />

1.37011<br />

Cs137<br />

30 years<br />

0.66 MeV<br />

6.4mm<br />

17.2mm<br />

25 Cig -1<br />

0.38184<br />

Ir192<br />

75 days<br />

0.14 ~ 1.2 MeV<br />

4.8mm<br />

?<br />

350 Cig -1<br />

0.59163<br />

(Aver. 0.34 MeV)<br />

Th232<br />

0.068376<br />

Dose rate* Rem/hr at one meter per curie<br />

Charlie Chong/ Fion Zhang


八 千 里 路 云 和 月<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


闭 门 练 功<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang<br />

http://greekhouse<strong>of</strong>fonts.com/


Charlie Chong/ Fion Zhang


Whole Chapter 5<br />

Radiation Measurement<br />

Charlie Chong/ Fion Zhang


PART 1. Principles <strong>of</strong> Radiation Measurement<br />

Emissions from radioactive nuclei and radiation from that portion <strong>of</strong> the<br />

electromagnetic spectrum beyond the ultraviolet energies can cause the<br />

ionization <strong>of</strong> atoms and molecules. Ionizing radiation occurs as three forms:<br />

(1) charged particles such as alpha particles, beta particles and protons,<br />

(2) uncharged particles such as neutrons and<br />

(3) electromagnetic radiation in the form <strong>of</strong> X-rays and gamma rays.<br />

Charlie Chong/ Fion Zhang


Radiation Detection Systems<br />

Some forms <strong>of</strong> radiation, such as light and heat, can be detected by human<br />

sense organs; ionizing radiation, however, can be detected only by the after<br />

effect <strong>of</strong> itsionizing properties. If ionizing radiation does not interact with<br />

matter, its detection and measurement is impossible. For this reason, the<br />

detection process uses substances that respond to radiation, as part <strong>of</strong> a<br />

system for measuring the extent <strong>of</strong> that response. The ionization process<br />

isused by a large class <strong>of</strong> detection systems, including:<br />

■ ion chambers,<br />

■ proportional chambers,<br />

■ geiger-müller counters and<br />

■ semiconductor devices (Table 1).<br />

■ Some systems depend on the excitation and molecular dissociation<br />

( 分 子 离 解 ) that occur with ionization. These processes are useful in (1)<br />

scintillation counters and (2) chemical dosimeters. Although other types <strong>of</strong><br />

detection systems exist, they are not generally used in radiation survey<br />

instruments.<br />

Charlie Chong/ Fion Zhang


TABLE 1. Effect <strong>of</strong> detected and measured ionization.<br />

Charlie Chong/ Fion Zhang


PART 2. Ion Chambers and Proportional<br />

Counters<br />

Principles <strong>of</strong> Ionization<br />

The mechanism most widely used in radiation survey applications is the<br />

ionization principle: charged particles producing ion pairs by direct interaction.<br />

These charged particles may (1) collide with electrons and remove them from<br />

their atoms or (2) transfer energy to an electron by the interaction <strong>of</strong> their<br />

electric fields (Fig. 1). If the energy transfer is not sufficient to completely<br />

remove an electron, the atom is left in a disturbed or excited state.<br />

Gamma and X-ray photons interact with matter mainly by:<br />

■ photoelectric absorption,<br />

■ compton scattering and<br />

■ pair production,<br />

each <strong>of</strong> which produces electrons and ions that may be collected and<br />

measured.<br />

Charlie Chong/ Fion Zhang


The average energy expended in the creation <strong>of</strong> an ion pair, in air and most<br />

gases, is about 34 eV) .<br />

The number <strong>of</strong> ion pairs produced per unit <strong>of</strong> path length is called specific<br />

ionization. Specific ionization is affected by the energy <strong>of</strong> the particle or<br />

photon by its change and by the nature <strong>of</strong> the ionized substance.<br />

Charlie Chong/ Fion Zhang


FIGURE 1. Ion pair (showing ejected electron and vacancy in electron orbit <strong>of</strong><br />

atom).<br />

pair<br />

34 eV for Air<br />

Charlie Chong/ Fion Zhang


Ionization Chambers<br />

In an ionization chamber, an electric field is applied across a volume <strong>of</strong> gas,<br />

between two electrodes. Often the chamber’s geometry is cylindrical, a<br />

cylindrical cathode enclosing the gas and an axial, insulated rod anode<br />

(Fig. 2). Charged particles, photons or both pass through the chamber and<br />

ionize the enclosed gas. When an electric field is applied to the gas, ions drift<br />

along the electrical lines <strong>of</strong> force to produce an ionization current. Under<br />

normal conditions, electrons drift at speeds <strong>of</strong> about 104 m·s –1 (22 000 mi·h –1).<br />

The drift velocity <strong>of</strong> positive ions is many orders <strong>of</strong> magnitude less. When the<br />

electric field is increased slightly from zero and a detector is placed in the<br />

constant radiation field the collected ions still will be few in number because<br />

many recombine. As the voltage is further increased, recombination yields to<br />

ionization, where all ions are collected (Fig. 3).<br />

Charlie Chong/ Fion Zhang


FIGURE 2. Basic ionization chamber with high value resistance R and<br />

voltage V.<br />

Charlie Chong/ Fion Zhang


Electromagnetic Energy Interactions<br />

Photons interact with subatomic structures in one <strong>of</strong> the following three ways:<br />

•Photoelectric absorption<br />

•Compton Scatter<br />

•Pair production<br />

The particular type <strong>of</strong> interaction reflects probability statistics based on both<br />

the energy <strong>of</strong> the photon and the atomic number <strong>of</strong> the traversed atom. For<br />

most tissues <strong>of</strong> the body, average atomic number does not vary greatly –<br />

though cortical bone has the highest effective atomic number.<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-02.html


Photoelectric Absorption<br />

An atom completely absorbs a photon, which then disappears; this excess<br />

energy provided to the atom ultimately results in ejection <strong>of</strong> an orbital electron.<br />

The ejected electron is known as a photo electron.<br />

Electrons have binding energies <strong>of</strong> orbit, with outer shells having less energy<br />

than those closer to the positive nucleus. When the initial orbital vacated is<br />

not that <strong>of</strong> an outer valance electron, the atom remains in a high-energy state<br />

until an outer orbital electron shifts to fill its incomplete inner shell. This shift is<br />

accompanied by emission <strong>of</strong> a characteristic X-ray.<br />

Photoelectric Absorption is an important interaction for low energy photons<br />

(


True or False?<br />

The "photo electron" and free radical can interact with other molecules --<br />

ultimately leading to ionizations and bond breakage, which are the<br />

biologically-important molecular manifestations <strong>of</strong> radiation damage.<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Compton Scatter<br />

Collision <strong>of</strong> a photon with an electron increases the kinetic energy <strong>of</strong> the<br />

electron. Thus set in motion, the electron is known as a recoil electron. The<br />

incident photon’s energy is not necessarily depleted, but it will diverge from its<br />

path and have lower energy -- i.e., it has a longer wavelength after collision.<br />

In diagnostic radiology, such scattered photons may lower contrast and thus<br />

degrade quality <strong>of</strong> the radiographic image.<br />

Important interaction for intermediate-energy photons (100 KeV to 10 MeV)<br />

Note:<br />

0.34 ~ 1.2 MeV (<strong>Exam</strong> Q)<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Compton Scatter<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Pair Production<br />

Note pair production requires relatively high photon energies that are<br />

generally not produced in diagnostic imaging.<br />

Photons with quantum energy in excess <strong>of</strong> 1.02 MeV (usually >10 MeV) may<br />

interact with matter to produce a negative electron and its anti-particle<br />

(positron). The value <strong>of</strong> 1.02 MeV equals the combination rest mass energy <strong>of</strong><br />

an electron and a positron.<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Pair Production<br />

0.51MeV<br />

0.51MeV<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Linear Energy Transfer [LET]<br />

LET is the amount <strong>of</strong> energy transferred to the local environment in the form<br />

<strong>of</strong> ionizations and excitations. Thus, LET indicates the potential for<br />

biologically important damage from radiation.<br />

Linear Energy Transfer can be thought <strong>of</strong> in two ways:<br />

• an average energy for a given path length traveled or<br />

• an average path length for a given deposited energy.<br />

The standard unit <strong>of</strong> measure is keV/um.<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Ionization tracts. When particulate or electromagnetic energy penetrates a<br />

cell, one or more ionizations will likely take place. While the precise site <strong>of</strong><br />

interaction is somewhat random, ionizations will distribute along distinct paths.<br />

The density <strong>of</strong> ionizations along a given path relates inversely to kinetic<br />

energy <strong>of</strong> the particle or photon.<br />

Thus a decelerating particle produces the greatest number <strong>of</strong> ionizations just<br />

before coming to rest. Comparing particles or photons, it follows also that LET<br />

for a gamma ray may be smaller than LET for an x-ray.<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Simulation <strong>of</strong> various radiation energies passing through a medium – each<br />

hatch mark represents an ionization. The heavy ion is a very high-LET<br />

particle; the delta ray represents secondary electrons with sufficient energy to<br />

make a separate ionization tract. The 5 keV electron is the typical energy <strong>of</strong> a<br />

secondary electron produced by X-ray photons used in diagnostic imaging.<br />

Note that absorption (and attenuation) <strong>of</strong> a photon beam is related to the<br />

atomic number <strong>of</strong> the impinged mass and inversely related to the energy <strong>of</strong><br />

the incident photon beam.<br />

The medium shown is approximately 200 nm in width – a DNA double helix<br />

width is about 2 nm.<br />

(Developed after Cox J.D. and Ang K.K., eds. Radiation Oncology Rationale,<br />

Technique, Results. 8th edition. St Louis, MO: Mosby, 2003. p44.)<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Simulation <strong>of</strong> various radiation energies passing through a medium<br />

Charlie Chong/ Fion Zhang<br />

https://www.med-ed.virginia.edu/courses/rad/radbiol/01physics/phys-03-03.html


Sources <strong>of</strong> Attenuation<br />

The attenuation that results due to the interaction between penetrating<br />

radiation and matter is not a simple process. A single interaction event<br />

between a primary x-ray photon and a particle <strong>of</strong> matter does not usually<br />

result in the photon changing to some other form <strong>of</strong> energy and effectively<br />

disappearing. Several interaction events are usually involved and the total<br />

attenuation is the sum <strong>of</strong> the attenuation due to different types <strong>of</strong> interactions.<br />

These interactions include the photoelectric effect, scattering, and pair<br />

production. The figure below shows an approximation <strong>of</strong> the total absorption<br />

coefficient, (µ), in red, for iron plotted as a function <strong>of</strong> radiation energy.<br />

The four radiation-matter interactions that contribute to the total absorption<br />

are shown in black. The four types <strong>of</strong> interactions are: photoelectric (PE),<br />

Compton scattering (C), pair production (PP), and Thomson or Rayleigh<br />

scattering (R). Since most industrial radiography is done in the 0.1 to 1.5 MeV<br />

range, it can be seen from the plot that photoelectric and Compton scattering<br />

account for the majority <strong>of</strong> attenuation encountered.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/CommunityCollege/<strong>Radiography</strong>/Physics/attenuation.htm


Total Absorption Coefficient, (µ),<br />

µ<br />

photoelectric (PE),<br />

Compton scattering (C),<br />

pair production (PP), and<br />

Thomson or Rayleigh scattering (R).<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Coherent scattering (also known as unmodified,<br />

classical or elastic scattering) is one <strong>of</strong> three forms <strong>of</strong> photon<br />

interaction which occurs when the energy <strong>of</strong> the X-ray or gamma photon is<br />

small in relation to the ionisation energy <strong>of</strong> the atom. It therefore occurs with<br />

low energy radiation.<br />

Upon interacting with the attenuating medium, the photon does not have<br />

enough energy to liberate the electron from its bound state (i.e. the photon<br />

energy is well below the binding energy <strong>of</strong> the electron) so no energy transfer<br />

occurs. The only change is a change <strong>of</strong> direction (scatter) <strong>of</strong> the photon,<br />

hence 'unmodified' scatter. Coherent scattering is not a major interaction<br />

process encountered in radiography at the energies normally used.<br />

Coherent scattering varies with the atomic number <strong>of</strong> absorber (Z) and<br />

incident photon energy (E) by Z 2 / E.<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/coherent-scattering


Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/coherent-scattering


Photoelectric effect, or photoelectric absorption (PEA)<br />

is a form <strong>of</strong> interaction <strong>of</strong> X-ray or gamma photon with the matter. A low<br />

energy photon interacts with the electron in the atom and removes it from its<br />

shell.<br />

The probability <strong>of</strong> this effect is maximum when:<br />

• the energy <strong>of</strong> the incident photon is equal to or just greater than the<br />

binding energy <strong>of</strong> the electron in its shell ('absorption edge') and<br />

• the electron is tightly bound (as in K shell)<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/photoelectric-effect


The electron that is removed is then called a photoelectron. The incident<br />

photon is completely absorbed in the process. Hence it forms one <strong>of</strong> the<br />

reason for attenuation <strong>of</strong> X-ray beam as it passes through the matter.<br />

PEA is related to the atomic number <strong>of</strong> the attenuating medium (Z), the<br />

energy <strong>of</strong> the incident photon (E) and the physical density <strong>of</strong> the attenuating<br />

medium (p) by: Z³ p / E³.<br />

Therefore, if Z doubles, PEA will increase by a factor <strong>of</strong> 8 (because 2³ is 8)<br />

and if E doubles, PEA will reduce by 8. As small changes in Z can have quite<br />

pr<strong>of</strong>ound changes in PEA this has practical implications in the field <strong>of</strong><br />

radiation protection and is why materials with a high Z such as lead (Z = 82)<br />

are useful shielding materials.<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/photoelectric-effect


The incident photon is<br />

completely absorbed<br />

in the process.<br />

Charlie Chong/ Fion Zhang


Photoelectric effect<br />

ABSORBED<br />

Charlie Chong/ Fion Zhang


Completely Heroes<br />

Charlie Chong/ Fion Zhang


Compton effect or Compton scatter is one <strong>of</strong> three principle<br />

forms <strong>of</strong> photon interaction. It is the main cause <strong>of</strong> scattered radiation in a<br />

material. It occurs due to the interaction <strong>of</strong> the X-ray or gamma photon with<br />

the outermost (and hence loosely bound) valence electron at the atomic level.<br />

The resultant incident photon gets scattered (changes direction) as well as<br />

ejects the electron (recoil electron), which further ionizes other atoms.<br />

Therefore the Compton effect is a partial absorption process and as the<br />

original photon has lost energy, this is known as Compton shift (the shift<br />

being a shift <strong>of</strong> wavelength/frequency).<br />

Probability <strong>of</strong> Compton effect:<br />

• directly proportional to<br />

• number <strong>of</strong> outer shell electrons, i.e. the electron density<br />

• physical density <strong>of</strong> material<br />

• inversely proportional to<br />

• photon energy<br />

• does not depend on<br />

• atomic number (unlike photoelectric effect and pair production)<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/compton-effect


History and etymology<br />

Named after Pr<strong>of</strong>essor Arthur Holly Compton (1892-<br />

1962), US physicist, who was awarded the Nobel Prize<br />

in Physics in 1927 for his discovery <strong>of</strong> Compton effect.<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Pair production (PP), like the photoelectric effect, results in the<br />

complete attenuation <strong>of</strong> the incident photon. Pair production can only occur if<br />

the incident photon energy is at least 1.022 MeV. As the photon interacts with<br />

the strong electric field around the nucleus it undergoes a change <strong>of</strong> state and<br />

is transformed into two particles (essentially creating matter from energy):<br />

■ one electron<br />

■ one positron (antimatter equivalent <strong>of</strong> the electron)<br />

These two particles form the pair referred to in the name <strong>of</strong> the process. It is<br />

noteworthy that other 'pairs' <strong>of</strong> leptons (<strong>of</strong> which the electron is a type) can be<br />

created such as muon - antimuon and tau - antitau pairs, however the type <strong>of</strong><br />

lepton pair would dictate the energy <strong>of</strong> the incident photon necessary to<br />

create them as both have far higher resting energy masses (1776 MeV for the<br />

tau and 105 MeV for the muon) than the electron and positron.<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/pair-production


The reason at least 1.022 MeV <strong>of</strong> photon energy is necessary is because the<br />

resting mass (using E=MC² ) <strong>of</strong> the electron and positron expressed in units<br />

<strong>of</strong> energy is 0.511 MeV (or 9.1 x 10 -31 kg) each, therefore unless there is at<br />

least 0.511 MeV *2 (i.e., 1.022 MeV) it is not possible for the electron-positron<br />

pair to be created. If the energy <strong>of</strong> the incident photon is greater than 1.022<br />

MeV, the excess is shared (although not always equally) between the<br />

electron and positron as kinetic energy.<br />

PP is related to the atomic number (Z) <strong>of</strong> attenuator, incident photon energy<br />

(E) and physical density (p) by Z E p.<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/pair-production


The electron and positron, once liberated within the medium are dissipated<br />

through successive interactions within the medium. The electron is quickly<br />

absorbed, however the fate <strong>of</strong> the positron is not so straight forward. As it<br />

comes to a rest, it combines with a neighbouring electron and the two<br />

particles neutralise each other in a phenomenon known as annihilation<br />

radiation. Here, the two particles are converted back into two photons <strong>of</strong><br />

electromagnetic radiation, each <strong>of</strong> 0.511 MeV energy travelling at 180<br />

degrees to each other (a concept utilised in positron emission tomography -<br />

PET). These photons are then absorbed or scattered within the medium.<br />

Pair production in reality does not become the dominant process in water<br />

below about 30 MeV (due to its dependence on the 'Z' <strong>of</strong> absorber) and is<br />

therefore <strong>of</strong> less importance in the low atomic number s<strong>of</strong>t tissue elements. In<br />

industrial radiography where high atomic number elements are irradiated, pair<br />

production can become the major attenuation process assuming the incident<br />

radiation energy exceeds 1.022 MeV.<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/pair-production


Pair Production<br />

Charlie Chong/ Fion Zhang


Summary <strong>of</strong> different mechanisms that cause<br />

attenuation <strong>of</strong> an incident x-ray beam<br />

Photoelectric (PE) absorption <strong>of</strong> x-rays occurs when the x-ray photon is<br />

(totally) absorbed, resulting in the ejection <strong>of</strong> electrons from the outer shell <strong>of</strong><br />

the atom, and hence the ionization <strong>of</strong> the atom. Subsequently, the ionized<br />

atom returns to the neutral state with the emission <strong>of</strong> an x-ray characteristic <strong>of</strong><br />

the atom. This subsequent emission <strong>of</strong> lower energy photons is generally<br />

absorbed and does not contribute to (or hinder) the image making process.<br />

Photoelectron absorption is the dominant process for x-ray absorption up to<br />

energies <strong>of</strong> about 500 KeV (


Photoelectric (PE) absorption<br />

Photoelectric (PE) absorption <strong>of</strong> x-rays<br />

occurs when the x-ray photon is (totally)<br />

absorbed, resulting in the ejection <strong>of</strong><br />

electrons from the outer shell <strong>of</strong> the<br />

atom.<br />

Charlie Chong/ Fion Zhang


Effect <strong>of</strong> Photon Energy on Attenuation<br />

Absorption characteristics will increase or decrease as the energy <strong>of</strong> the x-<br />

ray is increased or decreased. Since attenuation characteristics <strong>of</strong> materials<br />

are important in the development <strong>of</strong> contrast in a radiograph, an<br />

understanding <strong>of</strong> the relationship between material thickness, absorption<br />

properties, and photon energy is fundamental to producing a quality<br />

radiograph. A radiograph with higher contrast will provide greater probability<br />

<strong>of</strong> detection <strong>of</strong> a given discontinuity. An understanding <strong>of</strong> absorption is also<br />

necessary when designing x-ray and gamma ray shielding, cabinets, or<br />

exposure vaults.<br />

The applet below can be used to investigate the effect that photon energy has<br />

on the type <strong>of</strong> interaction that the photon is likely to have with a particle <strong>of</strong> the<br />

material (shown in gray). Various materials and material thicknesses may be<br />

selected and the x-ray energy can be set to produce a range from 1 to 199<br />

KeV. Notice as various experiments are run with the applets that low energy<br />

radiation produces predominately photoelectric events and higher energy x-<br />

rays produce predominately Compton scattering events. Also notice that if the<br />

energy is too low, none <strong>of</strong> the radiation penetrates the material.<br />

Charlie Chong/ Fion Zhang


This second applet is similar to the one above except that the voltage (KVp)<br />

for a typical generic x-ray tube source can be selected. The applet displays<br />

the spectrum <strong>of</strong> photon energies (without any filtering) that the x-ray source<br />

produces at the selected voltage. Pressing the "Emit X-ray" button will show<br />

the interaction that will occur from one photon with an energy within the<br />

spectrum. Pressing the "Auto" button will show the interactions from a large<br />

number <strong>of</strong> photos with energies within the spectrum.<br />

Charlie Chong/ Fion Zhang


More <strong>Reading</strong> on: Photoelectric effect<br />

The photoelectric effect is the emission <strong>of</strong> electrons from matter upon the<br />

absorption <strong>of</strong> electromagnetic radiation, such as ultraviolet radiation or x-rays.<br />

Upon exposing a metallic surface to electromagnetic radiation that is above<br />

the threshold frequency or threshold wavelength (absorption edge?) (which is<br />

specific to the type <strong>of</strong> surface and material), the photons are absorbed and<br />

current is produced.<br />

No electrons are emitted for radiation with a frequency below that <strong>of</strong> the<br />

threshold, as the electrons are unable to gain sufficient energy to overcome<br />

the electrostatic barrier presented by the termination <strong>of</strong> the crystalline surface.<br />

By conservation <strong>of</strong> energy, the energy <strong>of</strong> the photon is absorbed by the<br />

electron and, if sufficient, the electron can escape from the material with a<br />

finite kinetic energy.<br />

A single photon can only eject a single electron, as the energy <strong>of</strong> one photon<br />

may only be absorbed by one electron.<br />

The electrons that are emitted are <strong>of</strong>ten termed photoelectrons.<br />

Charlie Chong/ Fion Zhang<br />

https://www.sciencedaily.com/terms/photoelectric_effect.htm


Photoelectric effect, or photoelectric absorption (PEA)<br />

is a form <strong>of</strong> interaction <strong>of</strong> X-ray or gamma photon with the matter. A low<br />

energy photon interacts with the electron in the atom and removes it from its<br />

shell.<br />

The probability <strong>of</strong> this effect is maximum when:<br />

• the energy <strong>of</strong> the incident photon is equal to or just greater than the<br />

binding energy <strong>of</strong> the electron in its shell ('absorption edge') and<br />

• the electron is tightly bound (as in K shell) (?)<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/photoelectric-effect


The electron that is removed is then called a photoelectron. The incident<br />

photon is completely absorbed in the process. Hence it forms one <strong>of</strong> the<br />

reason for attenuation <strong>of</strong> X-ray beam as it passes through the matter.<br />

PEA is related to the atomic number <strong>of</strong> the attenuating medium (Z), the<br />

energy <strong>of</strong> the incident photon (E) and the physical density <strong>of</strong> the attenuating<br />

medium (ρ) by:<br />

PEA ∝ Z³ ·ρ / E³.<br />

Therefore, if Z doubles, PEA will increase by a factor <strong>of</strong> 8 (because 2³ is 8)<br />

and if E doubles, PEA will reduce by 8. As small changes in Z can have quite<br />

pr<strong>of</strong>ound changes in PEA this has practical implications in the field <strong>of</strong><br />

radiation protection and is why materials with a high Z such as lead (Z = 82)<br />

are useful shielding materials.<br />

Charlie Chong/ Fion Zhang<br />

http://radiopaedia.org/articles/photoelectric-effect


First principle mechanism <strong>of</strong> ionization<br />

The photoelectric effect <strong>of</strong> ionization involves the complete absorption <strong>of</strong> the<br />

photon energy during the process <strong>of</strong> knocking an electron out <strong>of</strong> orbit. This<br />

process primarily occurs with low energy photons ranging in energy between<br />

10 Kev and less than 500 Kev. (0.01~0.5MeV)<br />

Notice in the above illustration that an ion pair is created in the interaction<br />

between the radiation photon and the atom. During this process, when the<br />

photon liberates the electron, all <strong>of</strong> the photon s energy is transferred to create<br />

the ion pair and total absorption has occurred. Remember, there is a binding<br />

force that the holds the electron in its orbital shell. The amount <strong>of</strong> energy<br />

required to create the ion pair must be at least equal to this binding force.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/HighSchool/<strong>Radiography</strong>/photoelectric_popup.htm


If during the ionization process, only part <strong>of</strong> the photons energy is needed to<br />

liberate the electron, the rest <strong>of</strong> the energy is transferred to the electron in the<br />

form <strong>of</strong> speed (velocity). Now that all <strong>of</strong> the photon's energy is accounted for,<br />

the photon ceases to exist and total absorption has occurred. Remember that<br />

a photon is not a particle, but acts like one. When the energy <strong>of</strong> the photon is<br />

used, there is nothing left to cause further ionization.<br />

Keep in mind that electrons orbit in various shells <strong>of</strong> the atom and not all<br />

electrons have the same binding energy. This binding energy is dependent<br />

upon the elements (Z) number and the position <strong>of</strong> the electron in the atom.<br />

Those electrons nearer the nucleus possess greater binding energy and will<br />

require greater photon energy to remove them than will electrons in the outer<br />

shells.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/HighSchool/<strong>Radiography</strong>/photoelectric_popup.htm


Photoelectron Spectroscopy<br />

Charlie Chong/ Fion Zhang<br />

http://jahschem.wikispaces.com/Photoelectron+Spectroscopy


Photoelectron Spectroscopy<br />

Charlie Chong/ Fion Zhang<br />

http://www.met.reading.ac.uk/pplato2/h-flap/phys8_3.html


Photoelectron Spectroscopy<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikibooks.org/wiki/Basic_Physics_<strong>of</strong>_Digital_<strong>Radiography</strong>/The_Source


Photodisintegration (PD) is the process by which the x-ray photon is<br />

captured by the nucleus <strong>of</strong> the atom with the ejection <strong>of</strong> a particle from the<br />

nucleus when all the energy <strong>of</strong> the x-ray is given to the nucleus. Because <strong>of</strong><br />

the enormously high energies involved, this process may be neglected for the<br />

energies <strong>of</strong> x-rays used in radiography. (this photodisintegration to be<br />

distinguishes from photo annihilation <strong>of</strong> positron/electron pair)<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/CommunityCollege/<strong>Radiography</strong>/Physics/attenuation.htm


Thomson scattering (R), also known as Rayleigh, coherent, or classical<br />

scattering, occurs when the x-ray photon interacts with the whole atom so<br />

that the photon is scattered with no change in internal energy to the scattering<br />

atom, nor to the x-ray photon. Thomson scattering is never more than a minor<br />

contributor to the absorption coefficient. The scattering occurs without the<br />

loss <strong>of</strong> energy. Scattering is mainly in the forward direction.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/CommunityCollege/<strong>Radiography</strong>/Physics/attenuation.htm


FIGURE 3. Pulse size as function <strong>of</strong> voltage in gas ion chamber.<br />

Charlie Chong/ Fion Zhang


Ion current chambers have a response magnitude proportional to<br />

the absorbed energy and are therefore widely used for making dose<br />

measurements.<br />

When (1) recombination is negligible, (2) gas amplification does not occur<br />

and (3) all other charges are efficiently collected, then the steady state current<br />

produced is an accurate measurement <strong>of</strong> the rate at which ion pairs are<br />

formed within the gas.<br />

Measurement <strong>of</strong> this ionization current is the principle behind the direct<br />

current ion chamber. Ion chambers may be constructed <strong>of</strong> several different<br />

materials and, because radiation must penetrate the wall <strong>of</strong> the chamber to<br />

ionize the gas volume, chambers are chosen for the specific radiation energy<br />

being evaluated. When considering a particular instrument the energy<br />

response curve should always be consulted (Fig. 4). Some instruments may<br />

also have an angular dependence (more sensitivity in some directions), which<br />

should also be considered when making measurements. Radio frequency<br />

shielded ionization chambers are available for measurements made near high<br />

level radio frequency sources.<br />

Charlie Chong/ Fion Zhang


FIGURE 3. Pulse size as function <strong>of</strong> voltage in gas ion chamber.<br />

Charlie Chong/ Fion Zhang


FIGURE 4. Energy and directional response <strong>of</strong> typical ion chamber survey<br />

meters: (a) example <strong>of</strong> response curve; (b) comparison <strong>of</strong> several response<br />

curves.<br />

Charlie Chong/ Fion Zhang


FIGURE 4. Energy and directional response <strong>of</strong> typical ion chamber survey<br />

meters: (a) example <strong>of</strong> response curve; (b) comparison <strong>of</strong> several response<br />

curves.<br />

Legend<br />

Charlie Chong/ Fion Zhang


Ionization Chambers<br />

Charlie Chong/ Fion Zhang


Ionization Chambers<br />

Charlie Chong/ Fion Zhang


Compton scattering (C) (incoherent scattering)<br />

occurs when the incident x-ray photon is deflected from its original path by an<br />

interaction with an electron. The electron gains energy and is ejected from its<br />

orbital position. The x-ray photon loses energy due to the interaction but<br />

continues to travel through the material along an altered path. Since the<br />

scattered x-ray photon has less energy, it, therefore, has a longer wavelength<br />

than the incident photon. The event is also known as incoherent scattering<br />

because the photon energy change resulting from an interaction is not always<br />

orderly and consistent. The energy shift depends on the angle <strong>of</strong> scattering<br />

and not on the nature <strong>of</strong> the scattering medium<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/CommunityCollege/<strong>Radiography</strong>/Physics/attenuation.htm


Pair production (PP) can occur when the x-ray photon energy is greater than<br />

1.02 MeV, but really only becomes significant at energies around 10 MeV.<br />

Pair production occurs when an electron and positron are created with the<br />

annihilation <strong>of</strong> the x-ray photon. Positrons are very short lived and disappear<br />

(positron annihilation) with the formation <strong>of</strong> two photons <strong>of</strong> 0.51 MeV energy.<br />

Pair production is <strong>of</strong> particular importance when high-energy photons pass<br />

through materials <strong>of</strong> a high atomic number. (single photon for single pair<br />

production or single high energy photon for multiple pair production?)<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/CommunityCollege/<strong>Radiography</strong>/Physics/attenuation.htm


Output Current Measurements<br />

The ionization current collected in the ion chamber flows through an external<br />

circuit for measurement. Although in principle an ammeter could be placed in<br />

the external circuit to read the ion current, in practice the ammeter is not<br />

placed there, for the current is very small.<br />

A 440 cm 3 (27 in. 3 ) ion chamber typically produces about 4 × 10 –15 A·μSv –1<br />

(4 × 10 –14 A·mR –1 ) at standard temperature and pressure.<br />

A high valued load resistor (on the order <strong>of</strong> 10 10 Ω) is placed in the circuit and<br />

the voltage drop across the resistor is measured with a sensitive electrometer.<br />

A metal oxide silicon field effect transistor (MOSFET) is used in some<br />

electrometers. The metal oxide silicon field effect transistor produces an input<br />

impedance on the order <strong>of</strong> 10 15 Ω to amplify the collected current (Fig. 5).<br />

Charlie Chong/ Fion Zhang


FIGURE 5. Operational configuration <strong>of</strong> current amplifier.<br />

Charlie Chong/ Fion Zhang


Vibrating Reed Electrometers<br />

An alternative approach to ion current measurement is to convert the signal<br />

from direct current to alternating current at an early stage. This allows a more<br />

stable amplification <strong>of</strong> the alternating current signal in subsequent operations.<br />

The conversion is accomplished in a dynamic capacitor or vibrating reed<br />

electrometer, by collecting the ion current across a resistive capacitive circuit.<br />

The capacitance is then changed rapidly, compared to the time constant <strong>of</strong><br />

the circuit. The induced alternating current voltage is proportional to the<br />

ionization current (Fig. 6).<br />

Charlie Chong/ Fion Zhang


FIGURE 6. Principle <strong>of</strong> vibrating reed electrometer; oscillations <strong>of</strong><br />

capacitance induce alternating current voltage proportional to steady state<br />

signal current.<br />

Charlie Chong/ Fion Zhang


Vibrating Reed Electrometers<br />

Cary Vibrating Reed Electrometer with Ionization Chamber ( late 1950s)<br />

Charlie Chong/ Fion Zhang<br />

https://www.orau.org/PTP/collection/ionchamber/vibratingreedion.htm


Cary Vibrating Reed Electrometer with Ionization Chamber ( late 1950s)<br />

The spherical ion chamber,<br />

electrometer head, and amplifier were<br />

made by Applied Physics Corporation<br />

<strong>of</strong> Pasadena, California. The Model 31,<br />

which replaced the Model 30, was<br />

introduced in 1957/1958 and seems to<br />

have been superceded by the Model 32<br />

in 1959 This system would have been<br />

used to measure the activity <strong>of</strong><br />

chemically unreactive gases such as<br />

krypton, xenon, CO2 and HT. Either the<br />

gas being analyzed would flow through<br />

the chamber or be held inside the<br />

chamber for the duration <strong>of</strong> the<br />

measurement.<br />

Charlie Chong/ Fion Zhang<br />

https://www.orau.org/PTP/collection/ionchamber/vibratingreedion.htm


The weak current generated in the chamber (less than 10 -12 amperes) was<br />

converted into an alternating current by the vibrating reed in the electrometer<br />

head. The AC current was then amplified and fed to a strip chart recorder.<br />

The electrometer readout employed multiple scales and measured up to 30<br />

volts.<br />

The spherical ion chamber, shown to the right, is connected directly to the<br />

electrometer head. Made <strong>of</strong> stainless steel, it is approximately 3" in diameter<br />

and has a 250 ml volume. The original version <strong>of</strong> the chamber was made <strong>of</strong><br />

Pyrex. The reed, a thin metal plate, was vibrated by an electromagnet at<br />

frequency <strong>of</strong> 450 cycles per second. The reed also formed part <strong>of</strong> a capacitor<br />

onto which the current from the chamber was sent. The cyclical movement <strong>of</strong><br />

the reed resulted in a fluctuating capacitance and the generation <strong>of</strong> an<br />

alternating current. The advantage the AC signal had over the original DC<br />

signal was that the former could be amplified much more reliably.<br />

Charlie Chong/ Fion Zhang<br />

https://www.orau.org/PTP/collection/ionchamber/vibratingreedion.htm


An electrometer is an electrical instrument for measuring electric<br />

charge or electrical potential difference. There are many different types,<br />

ranging from historical handmade mechanical instruments to high-precision<br />

electronic devices. Modern electrometers based on vacuum tube or solidstate<br />

technology can be used to make voltage and charge measurements<br />

with very low leakage currents, down to 1 femtoampere. A simpler but related<br />

instrument, the electroscope, works on similar principles but only indicates<br />

the relative magnitudes <strong>of</strong> voltages or charges.<br />

Charlie Chong/ Fion Zhang


Older electrometers<br />

Gold-leaf electroscope<br />

The gold-leaf electroscope was one <strong>of</strong> the first sensitive instruments used to<br />

indicate electric charge. It is still used for science demonstrations but has<br />

been superseded in most applications by electronic measuring instruments.<br />

The instrument consists <strong>of</strong> two thin leaves <strong>of</strong> gold foil suspended from an<br />

electrode. When the electrode is charged by induction or by contact, the<br />

leaves acquire similar electric charges and repel each other due to the<br />

Coulomb force. Their separation is a direct indication <strong>of</strong> the net charge stored<br />

on them. On the glass opposite the leaves, pieces <strong>of</strong> tin foil may be pasted,<br />

so that when the leaves diverge fully they may discharge into the ground. The<br />

leaves may be enclosed in a glass envelope to protect them from drafts, and<br />

the envelope may be evacuated to minimize charge leakage.<br />

A further cause <strong>of</strong> charge leakage is ionizing radiation, so to prevent this, the<br />

electrometer must be surrounded by lead shielding. This principle has been<br />

used to detect ionizing radiation, as seen in the quartz fibre electrometer and<br />

Kearny fallout meter.<br />

Charlie Chong/ Fion Zhang


This type <strong>of</strong> electroscope usually acts as an indicator and not a measuring<br />

device, although it can be calibrated. The Braun[dubious electroscope<br />

replaced [when?] the gold-leaf electroscope for more accurate measurements.<br />

The instrument was developed in the 18th century by several researchers,<br />

among them Abraham Bennet and Alessandro Volta.<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang<br />

Volta Electrometers


Kolbe electrometer, precision form <strong>of</strong> goldleaf<br />

instrument. This has a light pivoted<br />

aluminum vane hanging next to a vertical<br />

metal plate. When charged the vane is<br />

repelled by the plate and hangs at an angle.<br />

Charlie Chong/ Fion Zhang


Gold-leaf electroscope<br />

Charlie Chong/ Fion Zhang


Modern electrometers<br />

A modern electrometer is a highly sensitive electronic voltmeter whose input<br />

impedance is so high that the current flowing into it can be considered, for<br />

most practical purposes, to be zero. The actual value <strong>of</strong> input resistance for<br />

modern electronic electrometers is around 10 14 Ω, compared to around 10 10 Ω<br />

for nanovoltmeters. Owing to the extremely high input impedance, special<br />

design considerations must be applied to avoid leakage current such as<br />

driven shields and special insulation materials.<br />

Among other applications, electrometers are used in nuclear physics<br />

experiments as they are able to measure the tiny charges left in matter by the<br />

passage <strong>of</strong> ionizing radiation. The most common use for modern<br />

electrometers is the measurement <strong>of</strong> radiation with ionization chambers, in<br />

instruments such as Geiger counters.<br />

Charlie Chong/ Fion Zhang


Vibrating reed electrometers<br />

Vibrating reed electrometers use a variable capacitor formed between a<br />

moving electrode (in the form <strong>of</strong> a vibrating reed) and a fixed input electrode.<br />

As the distance between the two electrodes varies, the capacitance also<br />

varies and electric charge is forced in and out <strong>of</strong> the capacitor. The alternating<br />

current signal produced by the flow <strong>of</strong> this charge is amplified and used as an<br />

analogue for the DC voltage applied to the capacitor. The DC input resistance<br />

<strong>of</strong> the electrometer is determined solely by the leakage resistance <strong>of</strong> the<br />

capacitor, and is typically extremely high, (although its AC input impedance is<br />

lower).<br />

For convenience <strong>of</strong> use, the vibrating reed assembly is <strong>of</strong>ten attached by a<br />

cable to the rest <strong>of</strong> the electrometer. This allows for a relatively small unit to<br />

be located near the charge to be measured while the much larger reed-driver<br />

and amplifier unit can be located wherever it is convenient for the operator.<br />

Charlie Chong/ Fion Zhang


Integrating Instruments<br />

The instruments described above (Fig. 7) are generally rate meters; that is,<br />

they indicate the radiation at the time <strong>of</strong> exposure and, depending on its time<br />

constant, will return to background levels as the source is removed. Some<br />

instruments may have an integration switch that introduces a capacitor to the<br />

circuit to accumulate the charge. Leaving such an instrument at an operator’s<br />

location will indicate the total amount <strong>of</strong> ionizing radiation that area has<br />

received, from the time the instrument is engaged.<br />

Charlie Chong/ Fion Zhang


FIGURE 7. <strong>Exam</strong>ples <strong>of</strong> ionization chambers located externally on survey<br />

instruments. Protective caps are removed, showing thin windows for low<br />

energy X-ray or beta detection.<br />

Charlie Chong/ Fion Zhang


Personnel Monitoring Instruments<br />

Pocket Chambers<br />

Personnel monitoring instruments, some the size <strong>of</strong> a ball point pen, are<br />

usually the integrating type and contain an ionization chamber. One version,<br />

the pocket chamber, requires the application <strong>of</strong> an initial charge <strong>of</strong> 150 to 200<br />

V by an external instrument. Zero dose is then indicated on a scale contained<br />

in the charging unit. Exposure <strong>of</strong> the chamber to ionization decreases the<br />

initial charge. When the chamber is reconnected to the charging unit the<br />

reduced charge is translated to the level <strong>of</strong> exposure (Fig. 8).<br />

Charlie Chong/ Fion Zhang


FIGURE 8. Cross section <strong>of</strong> quartz fiber pocket dosimeter.<br />

Legend<br />

1. Low atomic number wall<br />

2. Graphite coated paper shell<br />

3. Aluminum terminal head<br />

4. Aluminum terminal sleeve<br />

5. Polystyrene support bushing<br />

6. Central electrode, graphite coated<br />

7. Polyethylene insulating washer<br />

8. Polystyrene fixed bushing<br />

9. Electrode contact<br />

10. Retaining ring<br />

11. Aluminum base cap<br />

12. Polyethylene friction bushing<br />

Charlie Chong/ Fion Zhang


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang<br />

https://www.nde-ed.org/EducationResources/CommunityCollege/RadiationSafety/Graphics/DOSE.gif


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang


Pocket Chambers and Pocket Dosimeters<br />

Paul Frame, Oak Ridge Associated Universities<br />

Pocket chambers and pocket dosimeters are small ionization chambers that,<br />

as the name implies, are usually worn in the pocket. While they were<br />

designed to measure x-rays and gamma ray exposures, they would also<br />

respond to betas above 1 MeV. <strong>Neutron</strong>-sensitive versions were also<br />

available. The terms pocket chamber and pocket dosimeter are <strong>of</strong>ten used<br />

interchangeably. The original distinction between the two terms, used here, is<br />

rarely made anymore. In part, this is due to the fact that the devices that I call<br />

pocket chambers are rarely used any more.<br />

Note:<br />

pocket dosimeter is an ion chamber type.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


1. Pocket Chambers<br />

Pocket chambers go by a variety <strong>of</strong> names: indirect-reading dosimeters, nonself-reading<br />

dosimeters and condenser-type pocket dosimeters. Prior to WW<br />

II, they were only used to a limited extent, primarily in medical facilities and<br />

around accelerators. The Manhattan Project however created a huge demand<br />

and they were worn by almost everyone who might be exposed to radiation.<br />

A pocket chamber acts as an air-filled condenser (capacitor) much like the<br />

thimble chambers used in radiology. Prior to being worn, it is given a charge<br />

with a charger-reader, e.g., the Victoreen Minometer. Any subsequent<br />

exposure to radiation ionizes the air inside the chamber and this reduces the<br />

stored charge. In order to quantify the exposure, the charge is measured and<br />

the decrease is related to the exposure.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Manhattan Project<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Manhattan Project<br />

Charlie Chong/ Fion Zhang


Manhattan Project<br />

Charlie Chong/ Fion Zhang


Manhattan Project<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Manhattan Project<br />

Charlie Chong/ Fion Zhang


Manhattan Project<br />

Charlie Chong/ Fion Zhang


Manhattan Project Director<br />

J Robert Oppenheimer<br />

Charlie Chong/ Fion Zhang


WWII<br />

Charlie Chong/ Fion Zhang


Ion Chamber Charger<br />

& Reader<br />

PP-630(A)/PD Dosimeter Charger<br />

(ca. 1954-1961)<br />

The PP-630 (A)/PD Dosimeter<br />

Charger is the military equivalent <strong>of</strong><br />

the Keleket Model 430A chargerreader<br />

which was advertised as<br />

early as 1954. Since this PP-630(A)<br />

has "August 29 1961" stamped on it,<br />

I assume that it probably dates from<br />

1954 to 1961. Unfortunately I have<br />

not been able to locate any specific<br />

references to the PP-630A/PD.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/radiac/PP630.htm


Ion Chamber Charger & Reader<br />

Radiac Computer-Indicator CP-95A/PD is designed as a portable radiac computer-indicator, for computing & indicating the total amount <strong>of</strong> X and gamma radiation to which Radiac Detector<br />

DT-60()/PD has been exposed (and thus revealing the X and gamma radiation to which the wearer <strong>of</strong> the DT-60()/PD had been exposed). The CP-95A/PD operates in conjunction with<br />

Radiac Detector DT-60()/PD (not supplied) which contains a specially compounded silver-actuated phosphor glass. When the total radiation dosage <strong>of</strong> a DT-60()/PD is to be measured, the<br />

DT-60()/D is placed in Radiac Computer-Indicator C-95A/PD and exposed to a source <strong>of</strong> ultraviolet light. The ultraviolet light causes the silver-activated glass to emit an orange<br />

luminescence, the intensity <strong>of</strong> which is proportional to the total amount <strong>of</strong> radiation the glass has received. The intensity <strong>of</strong> the orange luminescence is measured by a photomultiplier tube<br />

which is fitted with a filter to prohibit the passage <strong>of</strong> blue and green light. The photomultiplier tube employs the principle <strong>of</strong> secondary emission to amplify the initial electron emission caused<br />

by the filtered orange illumination <strong>of</strong> the light-sensitive cathode. The output <strong>of</strong> the photomultiplier tube is applied to an indicating circuit to indicate the total amount <strong>of</strong> radiation to which the<br />

wearer <strong>of</strong> the DT60()/PD has been exposed.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/radiac/CP95APD.htm


Pocket chambers were approximately 4 - 5" long and 0.5" in diameter. An<br />

aluminum rod (ca. 0.0625” in diameter) running along the chamber axis<br />

served as one electrode, while the outer wall <strong>of</strong> the chamber served as the<br />

other electrode. The central electrode was suspended at each end with a<br />

polystyrene insulator and at one end it penetrated the insulator to serve as<br />

the charging contact. One problem with the early models involved the<br />

threaded caps that were used to protect the charging contact - they would<br />

wear and the metal fragments would get on the insulator. The graphite<br />

coating on the inside <strong>of</strong> the chamber wall caused a similar type <strong>of</strong> problem<br />

with some <strong>of</strong> the early models because it would sometimes flake <strong>of</strong>f and short<br />

out the chamber. The early models were also susceptible to discharge as a<br />

result <strong>of</strong> mechanical shock because the central electrode would flex and<br />

contact the chamber wall. To solve this problem, later versions used a thicker<br />

central electrode and/or positioned a small insulating disk in the center <strong>of</strong> the<br />

electrode. Because <strong>of</strong> these problems, it was usual for a worker to wear two<br />

dosimeters and the lower <strong>of</strong> the two readings was considered the most<br />

accurate.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


2. Pocket Dosimeters (quartz fiber electroscopes)<br />

Like pocket chambers, pocket dosimeters are known by a number <strong>of</strong> other<br />

names, e.g., direct-reading dosimeters, self-reading pocket dosimeters and<br />

pocket electroscopes. They are actually quartz fiber electroscopes the<br />

sensing element <strong>of</strong> which is a movable bow-shaped quartz fiber that is<br />

attached at each end to a fixed post. The latter is also shaped like a bow (or<br />

horseshoe). The dose is determined by looking through the eyepiece on one<br />

end <strong>of</strong> the dosimeter, pointing the other end towards a light source, and<br />

noting the position <strong>of</strong> the fiber on a scale. Until 1950 or so, the vast majority <strong>of</strong><br />

pocket dosimeters had a range up to 200 mR, although a few high range<br />

versions were available for emergency situations. Higher range versions<br />

became more readily available in the 1950s for military and civil defense<br />

purposes.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Pocket dosimeters tended to be slightly larger than pocket chambers. Their<br />

walls might be made <strong>of</strong> aluminum, bakelite, or some other type <strong>of</strong> plastic. If<br />

the material was not conductive, the inner surface <strong>of</strong> the chamber was coated<br />

with Aquadag (graphite). The central electrode was usually a phosphor<br />

bronze rod. This made pocket dosimeters more energy dependent than<br />

pocket chambers whose central electrodes were usually aluminum. Some<br />

dosimeters (e.g., Keleket Model K-145) employed boron-lined chambers<br />

which made them sensitive to thermal neutrons.<br />

Pocket dosimeters must be charged (ca. 150 ~ 200 volts) with some sort <strong>of</strong><br />

charger, but they do not require another device to read them. This allows the<br />

worker to determine his or her exposure at any time, an important advantage<br />

when working in high radiation fields.<br />

The first direct reading pocket dosimeters were built by Charlie Lauritsen at<br />

the California Institute <strong>of</strong> Technology.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


3. Pocket Chambers (indirect-reading) vs Pocket Dosimeters (direct<br />

reading)<br />

1. Pocket chambers were far less expensive (ca. $5 vs $40 in 1950)<br />

2. Pocket chambers, despite their problems, were more reliable.<br />

3. Pocket chambers did not permit the wearer to know their exposure, for<br />

military purposes, this was sometimes desirable.<br />

4. Pocket dosimeters allowed the worker to check their exposure during a<br />

particular task and to take corrective actions when appropriate.<br />

5. Pocket dosimeters did not have to be recharged every time they were read.<br />

6. Pocket dosimeters could use very small chargers, small enough to easily<br />

fit into a pocket.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Quartz Fiber Pocket Dosimeter.<br />

CDV-750 Dosimeter Charger and THREE (3) CDV-742 Dosimeters<br />

$260.00 The direct-reading pocket dosimeter is a portable instrument designed to measure the total dose <strong>of</strong> moderate and<br />

high levels <strong>of</strong> gamma radiation. The instruments make use <strong>of</strong> a small quartz fiber electroscope as an exposure detector and<br />

indicator. An image <strong>of</strong> the fiber is projected onto a film scale and viewed through the eyepiece lens. The scale is calibrated in<br />

roentgens (R) and may be read by looking through the eyepiece toward a lamp or other source <strong>of</strong> light. A CDV-750 dosimeter<br />

charger must be used in conjunction with the dosimeter to set the instrument to zero. The charger may also be used to read the<br />

scale or you can hold the dosimeter up to any light source and look through it.<br />

NOTE: the CDV-750 uses 1 D cell Battery (not included). The CDV-742 Dosimeter is an 'electroscope' it is electro statically<br />

charged by the CDV-750 charger. The Dosimeter does NOT use a battery. No battery to replace, no battery to go bad, EVER!<br />

Charlie Chong/ Fion Zhang<br />

http://josephdanielassociates.us/index.php?main_page=product_info&products_id=356


Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Charlie Chong/ Fion Zhang


Ion Chamber Charger & Reader<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Ion Chamber Charger & Reader<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


Quartz Fiber Pocket Dosimeter.<br />

Charlie Chong/ Fion Zhang<br />

http://www.orau.org/ptp/collection/dosimeters/pocketchamdos.htm


WWII Heroes<br />

Charlie Chong/ Fion Zhang


Direct <strong>Reading</strong> DosimetersThe direct reading dosimeter operates on the<br />

principle <strong>of</strong> the gold leaf electroscope (Fig. 9). A quartz fiber is displaced<br />

electrostatically by charging it to a potential <strong>of</strong> about 200 V. An image <strong>of</strong> the<br />

fiber is focused on a scale and viewedthrough a lens at one end <strong>of</strong> the<br />

instrument. Radiationexposure <strong>of</strong> the dosimeter discharges the fiber,<br />

allowing itto return to its original position.Personnel dosimeters may have a<br />

full scale reading <strong>of</strong> 1 to 50 mSv (100 mR to 5 R) (0.1R ~ 5R) and may have<br />

other scales according to applicable regulations. Chambers are available with<br />

thin walls for sensitivity to beta radiation over 1 MeV and may be coated on<br />

the inside with boron for neutron sensitivity. Figure 10 demonstrates the<br />

energy response <strong>of</strong> self- reading pocket dosimeters. Table 2 lists<br />

performance specifications <strong>of</strong> dosimeters in general.<br />

Keypoints:<br />

■ Chambers are available with thin walls for sensitivity to beta radiation<br />

1 MeV<br />

■ may be coated on the inside with boron for neutron sensitivity.<br />

Charlie Chong/ Fion Zhang


FIGURE 8. Cross section <strong>of</strong> quartz fiber pocket dosimeter.<br />

Charlie Chong/ Fion Zhang


FIGURE 9. Cross section <strong>of</strong> pocket (direct reading) ionization chamber.<br />

Charlie Chong/ Fion Zhang


FIGURE 10. Energy dependence <strong>of</strong> response <strong>of</strong> different commercial selfreading<br />

dosimeters.<br />

Charlie Chong/ Fion Zhang


TABLE 2. General performance specifications for dosimeters.<br />

Charlie Chong/ Fion Zhang


Proportional Counters<br />

If the electric field in an ion chamber is raised above the ionization potential<br />

but below saturation potential, enough energy is imparted to the ions for<br />

production <strong>of</strong> secondary electrons by collision and gas amplification.<br />

Operation at this electric potential overcomes the difficulty <strong>of</strong> the small<br />

currents in the ionization region yet takes advantage <strong>of</strong> pulse size<br />

dependence for separating various ionizing energies.<br />

When an ionization chamber is operated in this region it is called a<br />

proportional counter.<br />

The size <strong>of</strong> the output pulse is determined by, and proportional to, the number<br />

<strong>of</strong> electrons collected at the anode (n) and the voltage applied (V) at the<br />

detector (Output∝n·V) . By careful selection <strong>of</strong> gases and voltages, a<br />

properly designed proportional counter can detect alphas in the presence <strong>of</strong><br />

betas, or higher energy beta and gamma radiation in the presence <strong>of</strong> lower<br />

energies. Proportional counters are <strong>of</strong>ten used in X-ray diffraction<br />

applications.<br />

Charlie Chong/ Fion Zhang


REM (Roentgen equivalent man) – Dose Equivalent<br />

One <strong>of</strong> the two standard units used to measure the dose equivalent (or<br />

effective dose), which combines the amount <strong>of</strong> energy (from any type <strong>of</strong><br />

ionizing radiation that is deposited in human tissue), along with the medical<br />

effects <strong>of</strong> the given type <strong>of</strong> radiation. For beta and gamma radiation, the dose<br />

equivalent is the same as the absorbed dose. By contrast, the dose<br />

equivalent is larger than the absorbed dose for alpha and neutron radiation,<br />

because these types <strong>of</strong> radiation are more damaging to the human body.<br />

Thus, the dose equivalent (in rems) is equal to the absorbed dose (in rads)<br />

multiplied by the quality factor <strong>of</strong> the type <strong>of</strong> radiation [see Title 10, Section<br />

20.1004, <strong>of</strong> the Code <strong>of</strong> Federal Regulations (10 CFR 20.1004), "Units <strong>of</strong><br />

Radiation Dose"]. The related international system unit is the sievert (Sv),<br />

where 100 rem is equivalent to 1 Sv. For additional information, see Doses in<br />

Our Daily Lives and Measuring Radiation.<br />

先 有 rad 才 有 rem / 先 有 Gray 才 有 Sievert<br />

Charlie Chong/ Fion Zhang<br />

http://www.nrc.gov/reading-rm/basic-ref/glossary/rem-roentgen-equivalent-man.html


Townsend Discharges (Avalanches)<br />

The Townsend discharge or Townsend avalanche is a gas ionisation process<br />

where free electrons are accelerated by an electric field, collide with gas<br />

molecules, and consequently free additional electrons. Those electrons are in<br />

turn accelerated and free additional electrons. The result is an avalanche<br />

multiplication that permits electrical conduction through the gas. The<br />

discharge requires a source <strong>of</strong> free electrons and a significant electric field;<br />

without both, the phenomenon does not occur.<br />

The Townsend discharge is named after John Sealy Townsend, who<br />

discovered the fundamental ionisation mechanism by his work between 1897<br />

and 1901.<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


Sir John Sealy Townsend<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


General description <strong>of</strong> the phenomenon<br />

The avalanche occurs in a gaseous medium that can be ionised (such as air).<br />

The electric field and the mean free path <strong>of</strong> the electron must allow free<br />

electrons to acquire an energy level (velocity) that can cause impact<br />

ionisation. If the electric field is too small, then the electrons do not acquire<br />

enough energy. If the mean free path is too short, the electron gives up its<br />

acquired energy in a series <strong>of</strong> non-ionising collisions. If the mean free path is<br />

too long, then the electron reaches the anode before colliding with another<br />

molecule.<br />

A positive charge q is placed in a uniform<br />

electric field E set up between two charged<br />

parallel plates. If the particle is at a<br />

distance s from the negative plate, its<br />

electrical potential energy is qEs joules<br />

(C·N·C-1·m = N.m)<br />

http://www.physchem.co.za/OB11-ele/charge3.htm<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


Note:<br />

• If the electric field is too small, then the electrons do not acquire enough<br />

energy.<br />

• If the mean free path is too small, then the electrons do not acquire<br />

enough kinetic energy.<br />

• If the mean free path is too short, the electron collides too early with low<br />

energy, gives up its acquired energy in a series <strong>of</strong> non-ionising collisions.<br />

• If the mean free path is too long, then the electron reaches the anode<br />

before colliding with another molecule.<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


The avalanche mechanism is shown in the accompanying diagram. The<br />

electric field is applied across a gaseous medium; initial ions are created with<br />

ionising radiation (for example, cosmic rays, X radiation and gamma ray). An<br />

original ionisation event produces an ion pair; the positive ion accelerates<br />

towards the cathode while the free electron accelerates towards the anode. If<br />

the electric field is strong enough, the free electron can gain sufficient velocity<br />

(energy) (qEs) to liberate another electron when it next collides with a<br />

molecule.<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


The two free electrons then travel towards the anode and gain sufficient<br />

energy from the electric field to cause further impact ionisations, and so on.<br />

This process is effectively a chain reaction that generates free electrons.<br />

The total number <strong>of</strong> electrons reaching the anode is equal to the number <strong>of</strong><br />

collisions, plus the single initiating free electron. (n+1) Initially, the number <strong>of</strong><br />

collisions grows exponentially. (?) The limit to the multiplication in an electron<br />

avalanche is known as the Raether limit.<br />

The Townsend avalanche can have a large range <strong>of</strong> current densities. In<br />

common gas-filled tubes, such as those used as gaseous ionisation detectors,<br />

magnitudes <strong>of</strong> currents flowing during this process can range from about<br />

10 −18 amperes to about 10 −5 amperes.<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


Visualization <strong>of</strong> Proportional Counter Gas Magnification Event<br />

Single gas<br />

avalanche near<br />

the anode?<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


Visualization <strong>of</strong> Proportional Counter Gas Magnification Event<br />

Single gas<br />

avalanche near<br />

the anode?<br />

Charlie Chong/ Fion Zhang<br />

https://en.wikipedia.org/wiki/Townsend_avalanche


Multiple Gas Amplification due to multiple ionization<br />

Single gas<br />

avalanche near<br />

the anode<br />

Charlie Chong/ Fion Zhang


dose equivalent (in rems) is equal to the absorbed dose (in rads)<br />

multiplied by the quality factor <strong>of</strong> the type <strong>of</strong> radiation<br />

rems<br />

rads<br />

Charlie Chong/ Fion Zhang<br />

http://www.nrc.gov/reading-rm/basic-ref/glossary/rem-roentgen-equivalent-man.html


PART 3. Geiger-Müller Counters<br />

Operating Voltage Level<br />

Increasing voltage beyond the proportional region (Fig. 3) will eventually<br />

cause the gas avalanche to extend along the entire length <strong>of</strong> the anode wire.<br />

When this happens, the end <strong>of</strong> the proportionalregion is reached and the<br />

geiger-müller region begins. An instrument operating in this voltage range,<br />

using a sealed gas filled detector, is referred to as a geiger-müller counter, a<br />

GM counter or simply a geiger tube. This instrument was introduced in 1928<br />

and its simplicity and low cost have made it the most popular radiation<br />

detector since then. Geiger-müller counters complement the ion chamber and<br />

proportional counter and comprise the third category <strong>of</strong> gas filled<br />

detectors based on ionization.<br />

Charlie Chong/ Fion Zhang


Operating Voltage Level<br />

Charlie Chong/ Fion Zhang


Visualization <strong>of</strong> Geiger Muller Gas Magnification Event- Townsend<br />

Avalanches<br />

Multiple gas<br />

avalanche<br />

Charlie Chong/ Fion Zhang


Visualization <strong>of</strong> Geiger Muller Gas Magnification Event- Townsend<br />

Avalanches<br />

Visualization <strong>of</strong> the spread <strong>of</strong><br />

Townsend avalanches by means<br />

<strong>of</strong> UV photons. This mechanism<br />

allows a single ionising event to<br />

ionise all the gas surrounding the<br />

anode by triggering multiple<br />

avalanches.<br />

Charlie Chong/ Fion Zhang


Properties<br />

Extension <strong>of</strong> the gas avalanche increases the gas amplification factors so that<br />

10 9 to 10 10 ion pairs are formed in the discharge. This results in an output<br />

pulse large enough (0.25 to 10 V) to require no sophisticated electronic<br />

amplification circuitry for readout. At this voltage, the size <strong>of</strong> all pulses,<br />

regardless <strong>of</strong> the nature <strong>of</strong> the ionization, is the same.<br />

When operated in the geiger-müller region, a counter cannot distinguish<br />

among the several types <strong>of</strong> radiation and therefore is not useful for<br />

spectroscopy or for the detection <strong>of</strong> one energy event in the presence <strong>of</strong><br />

another. An external shield is <strong>of</strong>ten used to filter out alpha and beta particles<br />

in the presence <strong>of</strong> gamma energies.<br />

Note:<br />

The amplification factor: 10 9 to 10 10 ion pairs are formed in the discharge for<br />

single ionization <strong>of</strong> multiple events avalanches<br />

Charlie Chong/ Fion Zhang


Resolving Time<br />

As an ionizing event occurs in the counter, the avalanche <strong>of</strong> ions paralyzes<br />

the counter. The counter is then incapable <strong>of</strong> responding to another event<br />

until the discharge dissipates and proper potential is established.<br />

The time it takes to reestablish the electric field intensity is referred to as the<br />

resolving time.<br />

Average resolving time for a geiger-müller counter is about 100 ms, which<br />

must be corrected at high level readings. Resolving time τ <strong>of</strong> a counter may<br />

be determined by counting two sources independently (R 1 and R 2 ), then<br />

together (R 1 , R 2 ). The background count is R b .<br />

Charlie Chong/ Fion Zhang


Correct counting rate R can be calculated from observed counting rate R o<br />

andresolving time τ in the following equation for nonparalyzable systems:<br />

Charlie Chong/ Fion Zhang


Dead Time<br />

The relationship <strong>of</strong> resolving time to dead time and recovery is illustrated in<br />

Fig. 11.Resolving time may be a function <strong>of</strong> the detector alone or <strong>of</strong> the<br />

detector and its signal processing electronics. Its effect on the real counting<br />

rate depends on whether the system design is paralyzableor nonparalyzable.<br />

Charlie Chong/ Fion Zhang


FIGURE 11. Resolving time, dead time and recovery time for geiger-müller<br />

system.<br />

Charlie Chong/ Fion Zhang


Nonparalyzable Systems<br />

In Fig. 12, a time scale is shown indicating six randomly spaced events in the<br />

detector. At the bottom <strong>of</strong> the illustration is the corresponding dead time<br />

behavior <strong>of</strong> a detector assumed to be nonparalyzable. A fixed time τ follows<br />

each event that occurs during the live period <strong>of</strong> the detector. Events occurring<br />

during the dead time have no effect on the detector, which would record four<br />

counts from the six interactions.<br />

Charlie Chong/ Fion Zhang


FIGURE 12. Processing <strong>of</strong> detector interactions in paralyzable<br />

and nonparalyzable systems.<br />

Charlie Chong/ Fion Zhang


Paralyzable Systems The top line <strong>of</strong> Fig. 12 illustrates a paralyzable system.<br />

Resolving time τ follows each interaction, whether it is recorded or not.<br />

Events that occur during resolving time τ are not recorded and further extend<br />

the dead time by another period τ. The chart indicates only three recorded<br />

events from the six interactions. In this case, τ increases with increased<br />

number <strong>of</strong> interactions. It can be demonstrated that with a paralyzable system<br />

(at increasingly higher interaction rates), the observed counting rates can<br />

actually decrease with an increased number <strong>of</strong> events. When using a<br />

counting system that may be paralyzable, extreme caution must be taken to<br />

ensure that low observed counting rates correspond to low interaction rates,<br />

rather than very high interaction rates with accompanying, long dead time. It<br />

is possible for a paralyzable system to record the first interaction and then be<br />

paralyzed, recording zero counts in high radiation fields.<br />

Charlie Chong/ Fion Zhang


Quenching<br />

As positive ions are collected after a pulse, they give up their kinetic energy<br />

by striking the wall <strong>of</strong> the tube; Ultraviolet photons and/or electrons are<br />

liberated, producing spurious counts. Prevention <strong>of</strong> such counts is called<br />

quenching. Quenching may be accomplished electronically (by lowering the<br />

anode voltage after a pulse) or chemically (by using a self-quenching gas).<br />

■ Electronic Quenching (by lowering the anode voltage after a pulse)<br />

Electronic quenching is accomplished by introducing a high value <strong>of</strong><br />

resistance into the voltage circuit. This will drop the anode potential until all<br />

the positive ions have been collected.<br />

Charlie Chong/ Fion Zhang


■ Self-Quenching Gas (absorb ultraviolet (UV) photons)<br />

A self-quenching gas is one that can absorb ultraviolet (UV) photons without<br />

becoming ionized. One way to use this characteristic is to introduce a small<br />

amount <strong>of</strong> organic vapor, such as alcohol or ether, into the tube. The energy<br />

from the ultraviolet photons is then dissipated by dissociating the gas<br />

molecule. Such a tube is useful only as long as it has a sufficient number <strong>of</strong><br />

organic molecules to dissociate, generally about 10 8 counts.<br />

To avoid the problem <strong>of</strong> limited lifetime, some tubes use halogens (chlorine or<br />

bromine) as the quench gas. The halogen molecules also dissociate in the<br />

quenching process but they are replenished by spontaneous recombination at<br />

a later time. Halogen quench tubes have an infinite lifetime and are preferred<br />

for extended applications.<br />

Reaction products <strong>of</strong> the discharge <strong>of</strong>ten produce contamination <strong>of</strong> the gas or<br />

deposition on the anode surface and generally limit the lifetimes <strong>of</strong> geigermüller<br />

tubes.<br />

Charlie Chong/ Fion Zhang


FIGURE 13. Assortment <strong>of</strong> geiger-müller counters demonstrating availability<br />

<strong>of</strong> sizes and shapes. Smallest counter shown isabout 30 mm (1 in.) long.<br />

Charlie Chong/ Fion Zhang


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://solderpad.com/solderpad/mightyohm-geiger-counter/board/embed


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Geiger Muller<br />

Charlie Chong/ Fion Zhang<br />

http://www.jonshobbies.com/civil-defense-lionel-cd-v-700-model-6b-geiger-counter.html


Smart Geiger Counter<br />

Charlie Chong/ Fion Zhang<br />

http://akihabaranews.com/2015/10/05/article-en/app-enabled-geiger-counter-smartphones-113561601


Design Variations<br />

Geiger-müller counters (Fig. 13) are available in various shapes and sizes.<br />

The most common form is that <strong>of</strong> a cylinder with a central anode wire. If low<br />

energy beta or alpha particles are to be counted, a unit with a thin entrance<br />

window (1 to 4 mg·cm –2 ) should be selected. For surveying large surfaces,<br />

pancake or large window counters are available.<br />

High count rate instruments, greater than 0.14 mSv·s –1 (50 mR·h –1 ), generally<br />

contain a small tube to minimize resolving time <strong>of</strong> the system; large volume<br />

detectors may require significant correction.<br />

Note: small volume minimize resolving time<br />

A geiger-müller counter response to gamma rays occurs by way <strong>of</strong> gamma<br />

ray interaction with the solid wall <strong>of</strong> the tube. The incident gamma ray<br />

interacts with the wall and produces a secondary electron that subsequently<br />

reaches the gas. The probability <strong>of</strong> gamma ray interaction generally increases<br />

with higher density wall material.<br />

Charlie Chong/ Fion Zhang


A geiger-müller counter response to gamma rays occurs by way <strong>of</strong> gamma<br />

ray interaction with the solid wall <strong>of</strong> the tube. The incident gamma ray<br />

interacts with the wall and produces a secondary electron that subsequently<br />

reaches the gas. The probability <strong>of</strong> gamma ray interaction generally increases<br />

with higher density wall material.<br />

Note:<br />

■ Smaller chamber volume, minimize resolving time<br />

■ Gamma ray interact with the chamber wall<br />

■ Higher the density higher the probability <strong>of</strong> interaction<br />

■ Higher the atomic number higher the interaction<br />

Charlie Chong/ Fion Zhang


FIGURE 14. Dose rate ratio versus effective energy for<br />

personnel radiation monitor.<br />

Charlie Chong/ Fion Zhang


FIGURE 14. Dose rate ratio versus effective energy for<br />

personnel radiation monitor.<br />

Ir-192<br />

Charlie Chong/ Fion Zhang


TABLE 1. Characteristics <strong>of</strong> three isotope sources commonly used for<br />

radiography.<br />

Charlie Chong/ Fion Zhang


Alarming Rate Meters (Personnel Monitors)<br />

Small geiger-müller tubes are used in pocket-sized units for personnel<br />

monitoring. They generally emit a high frequency chirp at a rate proportional<br />

to the subjected dose rate. United States regulations specify an alarm<br />

threshold <strong>of</strong> 500 mSv·h –1 (500 mR·h –1 ) (500 μR·h–1) for field gamma<br />

radiography. The energy dependence curve for one such instrument is shown<br />

in Fig. 14.<br />

Charlie Chong/ Fion Zhang


Mini Geiger Muller Alarm Meter<br />

Charlie Chong/ Fion Zhang


Mini Geiger Muller Alarm Meter<br />

Charlie Chong/ Fion Zhang


Mini Geiger Muller Alarm Meter<br />

Charlie Chong/ Fion Zhang


Smart Geiger Counter<br />

Charlie Chong/ Fion Zhang<br />

http://xronosclock.com/home/?p=4238


Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Applications<br />

Geiger-müller counters are the most widely used, general purpose radiation<br />

survey instruments. It must be remembered that geiger-müller counters,<br />

unlike current ionization chambers, read pulses (regardless <strong>of</strong> their energy or<br />

ionizing potential) and register in counts per minute. Some instruments have<br />

a scale calibrated in milliroentgens per hour (mR·h –1 ); however, this is an<br />

arbitrary scale calibrated on the radiation from radium-226, cesium-137 or<br />

some other energy (Fig. 15). Another scale is microsieverts per second<br />

(μSv·s –1 ). A sensitivity versus energy table should always be consulted<br />

before making measurements with a geiger-müller instrument.<br />

Charlie Chong/ Fion Zhang


FIGURE 15. Typical energy response curves for geiger-müller counters<br />

(a) shielded versus unshielded;<br />

(b) radiation incident on side versus front;<br />

(c) exposure ratio close to ideal with radiation incident normal to long axis <strong>of</strong><br />

probe;<br />

(d) radiation incident normal to long axis <strong>of</strong> probe.<br />

Charlie Chong/ Fion Zhang


(a) shielded versus unshielded;<br />

Charlie Chong/ Fion Zhang


(b) radiation incident on side versus front;<br />

Charlie Chong/ Fion Zhang


(c) exposure ratio close to ideal with radiation incident normal to long axis <strong>of</strong><br />

probe;<br />

Charlie Chong/ Fion Zhang


(d) radiation incident normal to long axis <strong>of</strong> probe.<br />

Charlie Chong/ Fion Zhang


PART 4. Scintillation Detectors<br />

Soon after the discovery <strong>of</strong> X-rays and radioactivity, it was observed that<br />

certain materials emit visible light photons after interacting with ionizing<br />

radiation. These light photons appear to flash or sparkle and the materials are<br />

said to scintillate. Scintillators commonly used with radiation survey<br />

instruments are solid materials. Being denser than gases, these scintillators<br />

have greater detection efficiencies and are useful for low level measurements.<br />

For gamma photons, scintillators have detection efficiencies 10 6 times greater<br />

than typical gas ionization chambers. Detection <strong>of</strong> alpha and beta particles,<br />

neutrons and gamma photons is possible with various scintillator systems<br />

(Table 3).<br />

Charlie Chong/ Fion Zhang


TABLE 3. Common scintillators.<br />

Charlie Chong/ Fion Zhang


Scintillation Process<br />

Radiation interactions with matter produce excitation as well as irrigation.<br />

Ionization refers to the removal <strong>of</strong> an electron from an atom and excitation<br />

refers to the elevation <strong>of</strong> an electron’s energy state. The return <strong>of</strong> excited<br />

electrons to their normal, lower energy state is called deexcitation.<br />

Scintillators excited by ionizing radiation return to lower energy states quickly<br />

and emit visible light during the deexcitation process. Radiation detection is<br />

possible by measuring the scintillator’s light output (Fig. 16).<br />

Charlie Chong/ Fion Zhang


FIGURE 16. Energy diagram <strong>of</strong> scintillation process.<br />

Charlie Chong/ Fion Zhang


Materials and Characteristics<br />

Scintillation materials come in gaseous, liquid and solid forms. Organic liquids<br />

and solids, as well as inorganic gases and solids, are common scintillators.<br />

Organic, solid scintillators are available as crystals, plastics and gels.<br />

Inorganic solid scintillators are usually alkali halide crystals.<br />

The scintillation process in inorganic materials requires the presence <strong>of</strong> small<br />

amounts <strong>of</strong> an impurity, or activator. Inorganic solid scintillators are commonly<br />

used with radiation survey instruments and are listed in Table 3.<br />

Charlie Chong/ Fion Zhang


Desirable Scintillator Characteristics<br />

A useful and practical scintillator needs to have most <strong>of</strong> the characteristics<br />

listed below. Not all <strong>of</strong> these characteristics are ideally satisfied by each<br />

scintillator and <strong>of</strong>ten a compromise is acceptable.<br />

1. The scintillator should be <strong>of</strong> high density and large enough to ensure<br />

adequate interaction with the ionizing radiation.<br />

2. Efficient conversion <strong>of</strong> the electron’s kinetic energy into visible light is<br />

required and the light yield should be linearly related to the deposited<br />

electron kinetic energy.<br />

3. The scintillator should be <strong>of</strong> good optical quality, transparent to its emitted<br />

light and free <strong>of</strong> hydroscopic effects, and should have an index <strong>of</strong><br />

refraction close to that <strong>of</strong> glass.<br />

4. The wavelength <strong>of</strong> the emitted light should be appropriate for matching to<br />

a photomultiplier tube.<br />

Charlie Chong/ Fion Zhang


Photomultiplier Tubes<br />

Before the advent <strong>of</strong> photomultiplier tubes (PMTs), scintillation light photons<br />

had to be visually counted. This limited the use and development <strong>of</strong><br />

scintillators. In the 1940s, the photomultiplier tube was developed and<br />

dramatically increased the use <strong>of</strong> scintillators, to the point where scintillators<br />

are preferred over other radiation detectors for many survey applications. The<br />

photomultiplier tube’s function is to convert the scintillator’s light output into a<br />

electrical pulse. The photomultiplier tube is composed <strong>of</strong> a photosensitive<br />

layer, called the photocathode, and a number <strong>of</strong> electron multiplication<br />

structures called dynodes. Conversion <strong>of</strong> the scintillation light into<br />

photoelectrons is accomplished by the photocathodes through the<br />

photoelectric effect. To maximize the information contained in the scintillation<br />

light, the photomultiplier tube photocathode should be matched to the<br />

scintillator; the scintillator and photomultiplier tube should be optically coupled<br />

to minimize light losses.<br />

Charlie Chong/ Fion Zhang


Electron multiplication, or gain, is accomplished by positively charging the<br />

dynodes in successive stages, so that the total voltage applied to the<br />

photomultiplier tube is around 1000 V. Electrons emitted by the photocathode<br />

are focused toward the first dynode; more electrons are emitted than were<br />

initially incident on the dynode. This is repeated at each dynode stage. The<br />

photocathode and dynodes are positioned in a glass enclosed vacuum so<br />

that air molecules will not interfere with the collection <strong>of</strong> electrons. The net<br />

result <strong>of</strong> the photomultiplier tube may be an electron gain up to 10 10 per<br />

emitted photoelectron. Figure 17 illustrates the structure <strong>of</strong> a photomultiplier<br />

tube.<br />

Charlie Chong/ Fion Zhang


FIGURE 17. Cutaway drawing <strong>of</strong> photomultiplier tube, showing crystal,<br />

photocathode, collecting dynodes and voltage divider network.<br />

Charlie Chong/ Fion Zhang


PMT<br />

Charlie Chong/ Fion Zhang


PMT<br />

Charlie Chong/ Fion Zhang


PMT<br />

Charlie Chong/ Fion Zhang


PMT - Photomultiplier tubes lining the walls <strong>of</strong> the Daya Bay neutrino detector.<br />

The tubes are designed to amplify and record the faint flashes <strong>of</strong> light that<br />

signify an antineutrino interaction. This experiment aims to measure the final<br />

unknown mixing angle that describes how neutrinos oscillate — another<br />

chapter in Brookhaven National Laboratory's long history <strong>of</strong> neutrino research<br />

over the last several decades.<br />

Charlie Chong/ Fion Zhang<br />

https://www.bnl.gov/newsroom/news.php?a=24055


System Electronics<br />

Once the output pulse from a photomultiplier tube is generated, it is amplified<br />

and analyzed. The pulse height, or amplitude, is proportional to the amount <strong>of</strong><br />

energy deposited within the scintillator and can be correlated to a count rate<br />

or scale <strong>of</strong> microsievert per second (μSv·s –1 ) or milliroentgen per hour<br />

(mR·h –1 ) when calibrated against a known energy source. (See Fig. 18.)<br />

Charlie Chong/ Fion Zhang


FIGURE 18. Comparison <strong>of</strong> sodium iodide (thallium activated) and<br />

germanium detectors for gamma spectroscopy.<br />

Charlie Chong/ Fion Zhang<br />

Energy (MeV)


PART 5. Luminescent Dosimetry<br />

Thermoluminescent Dosimetry<br />

Thermoluminescence is the emission <strong>of</strong> light from previously irradiated<br />

materials after gentle heating. The radiation effect in thermoluminescent (TL)<br />

materials is similar to that observed in scintillators, except that light photon<br />

emission does not occur in thermoluminescent materials until some heat<br />

energy is supplied (Fig. 19). Measurement <strong>of</strong> the light photons emitted after<br />

heating permits correlation to the amount <strong>of</strong> ionizing radiation energy that was<br />

absorbed in the thermoluminescent material.<br />

Thermoluminescent dosimetry (TLD) is possible for beta, gamma and neutron<br />

(alpha?) radiations, if the appropriate thermoluminescent material is used.<br />

Charlie Chong/ Fion Zhang


Thermoluminescence<br />

Charlie Chong/ Fion Zhang


Thermoluminescence<br />

Charlie Chong/ Fion Zhang


Lithium Fluoride Properties<br />

The most common thermoluminescent phosphor used in gamma and neutron<br />

personnel dosimetry is lithium fluoride ( 6 3LiF for neutron detection)) .<br />

Other thermoluminescent phosphors are available for personnel dosimetry<br />

but, for various reasons, are not as well suited as lithium fluoride. The<br />

advantages <strong>of</strong> lithium fluoride include its:<br />

1. usefulness over a wide dose range,<br />

2. linear dose response,<br />

3. near dose rate independence,<br />

4. reusability,<br />

5. stability,<br />

6. short readout time and<br />

7. near tissue equivalence.<br />

Charlie Chong/ Fion Zhang


Disadvantages include the loss <strong>of</strong> information after readout and lack <strong>of</strong><br />

information about the incident radiation energy.<br />

Both gamma photons and neutrons produce ionization indirectly. Gamma<br />

photons interact with matter, releasing electrons that in turn cause ionization.<br />

Lithium fluoride undergoes interactions with gamma photons and is therefore<br />

used in gamma dosimetry.<br />

Slow neutrons require the presence <strong>of</strong> the lithium fluoride enriched with<br />

lithium-6 for detection <strong>of</strong> the (n, α) nuclear reaction.<br />

6<br />

3 Li + n → 4 2 He + 2 1 D + γ<br />

Charlie Chong/ Fion Zhang


Fast neutron detection with lithium fluoride would only be possible if the fast<br />

neutrons were slowed down to thermal energies before reaching the lithium<br />

fluoride thermoluminescent dosimeter. Nearly complete elimination <strong>of</strong> neutron<br />

response in lithium fluoride is possible with lithium fluoride enriched with<br />

lithium-7. In a mixed gamma and slow neutron field, distinction <strong>of</strong> gamma and<br />

neutron doses is possible by comparing the readings <strong>of</strong> two lithium fluoride<br />

thermoluminescent dosimeters with different lithium-6 contents.<br />

Keywords:<br />

• Nearly complete elimination <strong>of</strong> neutron response in lithium fluoride is<br />

possible with lithium fluoride enriched with lithium-7.<br />

• In a mixed gamma and slow neutron field, distinction <strong>of</strong> gamma and<br />

neutron doses is possible by comparing the readings <strong>of</strong> two lithium<br />

fluoride thermoluminescent dosimeters with different lithium-6 contents.<br />

Charlie Chong/ Fion Zhang


Thermoluminescent Dosimetric Readout Systems<br />

Thermoluminescent dosimetric readout systems are commonly made up <strong>of</strong> a<br />

sample holder, heating system, photomultiplier tube (light detector), high<br />

voltage supply, signal amplifier and a recording instrument. The<br />

thermoluminescent dosimetric sample is heated indirectly, using electrical<br />

resistance heat applied to a pan or planchette. The photomultiplier tube<br />

converts the light output into an electronic pulse that is then amplified before<br />

recording. The recording instrument may be a plotter or any other instrument<br />

that can measure the amplified photomultiplier tube output signal. A plot <strong>of</strong><br />

the output signal versus time is equivalent to emitted light intensity versus<br />

heat and results in a glow curve.<br />

The area under the glow curve is proportional to the absorbed dose (Fig. 20).<br />

Uses <strong>of</strong> thermoluminescent measurement <strong>of</strong> radiation include personnel<br />

dosimetry, medical dosimetry, environmental monitoring and archeological<br />

and geological dating.<br />

Charlie Chong/ Fion Zhang


FIGURE 19. Thermoluminescence process.5<br />

Charlie Chong/ Fion Zhang


FIGURE 20. Typical glow curve. Integrated area under curve is measure <strong>of</strong><br />

radiation exposure.<br />

Charlie Chong/ Fion Zhang


Optically Stimulated Luminescence Dosimetry<br />

Optically stimulated luminescence dosimeters typically have aluminum oxide<br />

detectors and are available in plastic holders, or body badges, that are worn<br />

at collar level to measure full body dose. They can measure gamma ray and<br />

X-ray doses from 10μSv to 10Sv (1 mrem to 1 krem).<br />

Charlie Chong/ Fion Zhang


TDL<br />

Charlie Chong/ Fion Zhang<br />

http://www.rpe.org.in/article.asp?issn=0972-0464;year=2011;volume=34;issue=1;spage=6;epage=16;aulast=Bhatt;type=3


TDL<br />

Charlie Chong/ Fion Zhang<br />

http://www.rpe.org.in/article.asp?issn=0972-0464;year=2011;volume=34;issue=1;spage=6;epage=16;aulast=Bhatt;type=3


TDL<br />

Charlie Chong/ Fion Zhang<br />

http://www.rpe.org.in/article.asp?issn=0972-0464;year=2011;volume=34;issue=1;spage=6;epage=16;aulast=Bhatt;type=3


TDL<br />

Charlie Chong/ Fion Zhang<br />

http://www.rpe.org.in/article.asp?issn=0972-0464;year=2011;volume=34;issue=1;spage=6;epage=16;aulast=Bhatt;type=3


PART 6. <strong>Neutron</strong> Detection<br />

Characteristics<br />

The neutron is a part <strong>of</strong> the nucleus, has no charge and is somewhat larger in<br />

mass than the proton. It is similar to the photon in that it has no charge and<br />

produces ionization indirectly; it is different from the photon because it is a<br />

nuclear particle and not a unit <strong>of</strong> electromagnetic energy. Because the<br />

neutron is an uncharged particle, its interactions with matter are different from<br />

those <strong>of</strong> charged particles or photons. Ionization by neutrons is indirect: as a<br />

result <strong>of</strong> neutron interactions with matter, recoil nuclei, photons or charged<br />

particles are produced and then interact with matter by various mechanisms<br />

that cause ionization.<br />

Charlie Chong/ Fion Zhang


<strong>Neutron</strong> Sources<br />

<strong>Neutron</strong>s are classified according to their energies as shown in Table 4.<br />

Some radionuclides (such as californium-252) may decay by<br />

spontaneousfission and emit neutrons with fission fragments, photons and<br />

electrons.<br />

Induced fission reactions, such as those occurring in a nuclear reactor with<br />

uranium, emit about 2.5 neutrons per fission. Fission neutrons range in<br />

energy from 0.025 eV to about 16 MeV.<br />

Other neutron sources are the result <strong>of</strong> various nuclear reactions and produce<br />

either a spectrum <strong>of</strong> neutron energies or monoenergetic neutrons. Common<br />

neutron producing nuclear reactions are the (γ, n), (α, n), (p, n), (d, n) and (α,<br />

2n) reactions and may use radionuclide emissions or accelerated particles to<br />

initiate the reaction. <strong>Neutron</strong> radiography usually uses radionuclides that emit<br />

alpha or gamma photons and produce neutrons by (α, n) and (γ, n) reactions<br />

with various target materials.<br />

Charlie Chong/ Fion Zhang


TABLE 4. <strong>Neutron</strong> classification.<br />

Class<br />

Thermal<br />

Epithermal<br />

Slow<br />

Intermediate<br />

Fast<br />

Relativistic greater than<br />

Energy<br />

< 0.3 meV<br />

>1 eV<br />

0 meV to 100 eV<br />

100 eV to 10 keV<br />

10 keV to 10 MeV<br />

10 MeV<br />

Charlie Chong/ Fion Zhang


<strong>Neutron</strong> Detectors<br />

There are several mechanisms and devices used to detect neutrons <strong>of</strong><br />

various energies. Ionization chambers, proportional counters, scintillators,<br />

activation foils, track etch detectors, film emulsions, nuclear emulsions and<br />

thermoluminescent phosphors are some <strong>of</strong> the many devices used to detect<br />

neutrons. The main mechanisms used to detect neutrons in these devices are<br />

the (n, α), (n, p), (n, d), (n, f) and (n, γ) nuclear reactions.<br />

(n, f ) f= fragments<br />

Proportional <strong>Neutron</strong> Detectors Many fast and slow neutron counters use<br />

proportional counting chambers filled with boron trifluoride (BF 3 ) gas, <strong>of</strong>ten<br />

enriched in boron-10. The interaction <strong>of</strong> thermal (slow) neutrons with boron<br />

gas releases an alpha particle <strong>of</strong> several mega electron volts that is easily<br />

detected in the proportional mode. Fast neutrons are detected by a similar<br />

counter, in which thermal neutrons are absorbed in an external cadmium<br />

shield; the fast neutrons that pass through the shield are thermalized in<br />

hydrogen rich material and counted in the proportional chambers.<br />

10<br />

5 B + n → 4 2 He2+ + 7 3 Li + γ<br />

Charlie Chong/ Fion Zhang


Scintillation<br />

Scintillators containing lithium-6, boron-10 and hydrogenous plastics have<br />

been used as neutron detectors. Lithium-6 is used as lithium iodide (europium<br />

activated) and in lithium glasses to detect slow and fast neutrons. Scintillators<br />

loaded with boron-10 are used for slow neutron detection. Plastic scintillators<br />

with high hydrogen content are used in fast neutron detection and<br />

spectroscopy by measuring the energy deposited by recoil protons.<br />

Activation Foils Introducing certain materials to an incident neutron flux will<br />

result in these materials becoming radioactive. The process is called<br />

activation and gaining information about the incident neutron flux and energy<br />

is possible by analyzing the radiations emitted from the activated foil.<br />

Activation foils rely on (n, γ), (n, p), (n, α), (n, f ) and other nuclear reactions<br />

to cause the activation. Selection <strong>of</strong> the proper activation foil can give a rough<br />

estimate <strong>of</strong> the neutron energy spectrum. In high neutron flux fields, where<br />

instruments would fail, activation foils are used as integrating detectors.<br />

Charlie Chong/ Fion Zhang


Miscellaneous <strong>Neutron</strong> Detectors Track etch detectors, nuclear<br />

emulsions and film have all been used to detect neutrons. Various neutron<br />

interactions with the detector material or foils in intimate contact with the<br />

detectors allow these systems to operate as integrating dosimeters.<br />

Charlie Chong/ Fion Zhang


TABLE 6. Properties <strong>of</strong> Some Thermal <strong>Neutron</strong> <strong>Radiography</strong> Conversion Materials<br />

Material<br />

Useful Reactions<br />

Cross Section for<br />

Life<br />

Thermal <strong>Neutron</strong>s (barns)<br />

Lithium<br />

6 Li(n,α) 3 H<br />

910<br />

prompt<br />

Boron<br />

10 B(n,α) 7 Li<br />

3,830<br />

prompt<br />

Rhodium<br />

103 Rh(n) 104m Rh<br />

11<br />

45 min<br />

103<br />

Rh(n) 104 Rh<br />

139<br />

42 s<br />

Silver<br />

107 Ag(n) 108 Ag<br />

35<br />

2.3 min<br />

109 Ag (n) 110 Ag<br />

91<br />

24 s<br />

Cadmium<br />

113 Cd((n,γ) 114 Cd<br />

20,000<br />

prompt<br />

Indium<br />

115 In(n) 116 n<br />

157<br />

54 min<br />

115<br />

In(n) 116m ln<br />

42<br />

14 s<br />

Samarium<br />

149 Sm(n,γ) 150 Sm<br />

41,000<br />

prompt<br />

I52<br />

Sm(n) 153 Sm<br />

210<br />

47 h<br />

Europium<br />

151 Eu(n) 152 Eu<br />

3,000<br />

9.2 h<br />

Gadolinium<br />

155<br />

Gd(n,γ) I56 Gd<br />

61,000<br />

prompt<br />

157<br />

Gd(n.γ) 158 Gd<br />

254,000<br />

prompt<br />

Dyprosium<br />

164<br />

Dy(n) 165 mDy<br />

2,200<br />

1.25 min<br />

164<br />

Dy(n) 165 Dy<br />

800<br />

140 min<br />

Gold<br />

197 Au(n) 198 Au<br />

99<br />

2.7 days<br />

Charlie Chong/ Fion Zhang


PART 7. Semiconductors<br />

Certain semiconductor crystals, when exposed to ionizing radiation, become<br />

conductors and may be used as radiation detectors. Semiconductors are<br />

most <strong>of</strong>ten used for low level spectroscopic measurements <strong>of</strong> alpha particles,<br />

beta particles and gamma rays in laboratory settings and in X-ray diffraction<br />

equipment (Table 5). The most widely used semiconductor devices are<br />

diffused p-n junction, surface barrier and lithium drifted detectors.<br />

Semiconductor detectors have found their broadest application in the field <strong>of</strong><br />

spectroscopy, although lithium drifted detectors are also being used for<br />

gamma ray detection.<br />

Charlie Chong/ Fion Zhang


Detector<br />

The diffused p-n junction detector (Fig. 21a) gets its name from its<br />

manufacturing process. A slice <strong>of</strong> p type (electron depleted) silicon or<br />

germanium crystal, with a layer <strong>of</strong> n type (electron rich) impurity (usually<br />

phosphorus) deposited on the surface, is heated to form a p-n junction just<br />

below the surface. The phosphorus may also be painted onto the silicon and<br />

made to diffuse into it by applying heat. Because the n type material has an<br />

excess <strong>of</strong> electrons and the p type has an excess <strong>of</strong> holes (holes may be<br />

thought <strong>of</strong> as unit positive charges), the natural action <strong>of</strong> the combined<br />

materials tends to align the electrons on one side <strong>of</strong> the junction and the<br />

holes on the other. Thus a difference <strong>of</strong> potential is built up across the<br />

junction. By applying an external voltage to the crystal <strong>of</strong> such polarity as to<br />

oppose the natural movement <strong>of</strong> electrons and holes (reverse bias), the<br />

potential barrier across the junction is increased and a depletion region is<br />

produced.<br />

Charlie Chong/ Fion Zhang


This depletion region is the sensitive part <strong>of</strong> the detector and is analogous to<br />

the gas volume in a gas ionization detector. Charged particles, on entering<br />

the depletion region, produce electron hole pairs analogous to the ion pairs<br />

produced in gas ionization chambers. Because an electric field exists in this<br />

region, the charge produced by the ionizing particle is collected, producing a<br />

pulse <strong>of</strong> current. The size <strong>of</strong> the pulse is proportional to the energy expended<br />

by the particle.<br />

Charlie Chong/ Fion Zhang


Surface Barrier Detectors<br />

The operation <strong>of</strong> surface barrier and lithium drifted detectors is the same as<br />

for the p-n junction: a depletion region is produced, in which there exists an<br />

electric field. The means <strong>of</strong> producing the depletion region (as well as its<br />

dimension and location within the crystal) vary from one type <strong>of</strong> detector to<br />

another. The operation <strong>of</strong> a surface barrier detector (Fig. 21b) depends on the<br />

surface conditions <strong>of</strong> the silicon or germanium. At the surface <strong>of</strong> a piece <strong>of</strong><br />

pure crystal, an electric field exists such that both holes and electrons are<br />

excluded from a thin region near the surface. For n type crystals, the field<br />

repels free electrons. If a metal is joined to the crystal, the free electrons are<br />

still repelled but a concentration <strong>of</strong> holes is produced directly under the<br />

surface. If a reverse bias is then applied, a depletion region is produced.<br />

Surface barrier detectors give better resolution for particle spectroscopy than<br />

p-n junctions but wider depletion regions are possible with the latter. (The<br />

wider the depletion region, the higher the energy <strong>of</strong> particles can be analyzed<br />

because a particle must expend all its energy in a depletion region.)<br />

Charlie Chong/ Fion Zhang


Lithium Drifted Detectors<br />

The lithium drifted detector (Fig. 22) is produced by diffusing lithium into low<br />

resistivity p-type silicon or germanium. When heated under reverse bias, the<br />

lithium ions serve as an n type donor. These ions drift into the silicon or<br />

germanium in such a way that a wide layer <strong>of</strong> the p type material is<br />

compensated by the lithium, yielding an effective resistivity comparable to that<br />

<strong>of</strong> the intrinsic material. Wider depletion regions can be obtained with the<br />

lithium drift process than by any other means. Consequently, lithium drifted<br />

detectors are most useful in gamma spectroscopy work. Silicon detectors can<br />

be operated at room temperatures but exhibit low efficiency for gamma rays.<br />

Germanium detectors have higher gamma efficiencies but must be operated<br />

at liquid nitrogen temperatures. For these reasons, coupled with the small<br />

sensitive volumes obtainable to date, semiconductor detectors have not<br />

received widespread application in radiation survey instruments.<br />

Charlie Chong/ Fion Zhang


TABLE 5. Radiation detector types.<br />

Charlie Chong/ Fion Zhang


FIGURE 21. Cross sections: (a) diffused p-n junction detector;<br />

(b) surface barrier detector.<br />

Charlie Chong/ Fion Zhang


FIGURE 21. Cross sections: (a) diffused p-n junction detector;<br />

(b) surface barrier detector.<br />

Charlie Chong/ Fion Zhang


FIGURE 22. Cross section <strong>of</strong> lithium drifted detector.<br />

Charlie Chong/ Fion Zhang


PART 8. Film Badges<br />

One <strong>of</strong> the most important uses <strong>of</strong> radiographic film as a means <strong>of</strong> measuring<br />

radiation is in film badges. Individuals who work with isotope radiation<br />

sources and X-ray machines are required by codes to wear badges indicating<br />

cumulative exposure to ionizing radiation. Film badges are discussed in this<br />

volume’s chapter on radiation safety and elsewhere<br />

Charlie Chong/ Fion Zhang


Latent Image Formation<br />

Latent image formation is a very subtle change in the silver halide grain <strong>of</strong> film.<br />

The process may involve the absorption <strong>of</strong> only one or, at most, a few<br />

photons <strong>of</strong> radiation and this may affect only a few atoms out <strong>of</strong> some 10 9 or<br />

10 10 atoms in a typical photographic grain. Formation <strong>of</strong> the latent image,<br />

therefore, cannot be detected by direct physical or analytical chemical means.<br />

The process that made an exposed photographic grain capable <strong>of</strong><br />

transformation into metallic silver (by the mild reducing action <strong>of</strong> a developer)<br />

involved a concentration <strong>of</strong> silver atoms at one or more discrete sites on the<br />

photographic grain. In industrial radiography, the image forming effects <strong>of</strong> X-<br />

rays and gamma rays, rather than those <strong>of</strong> light, are <strong>of</strong> primary interest.<br />

The agent that actually exposes a film grain (a silver bromide crystal in the<br />

emulsion) is not the X-ray photon itself but rather the electrons (photoelectric<br />

and compton) resulting from an absorption event.<br />

The most striking difference between X-ray and visible light exposures arises<br />

from the difference in the amounts <strong>of</strong> energy involved.<br />

Charlie Chong/ Fion Zhang


The absorption <strong>of</strong> a single photon <strong>of</strong> light transfers a very small amount <strong>of</strong><br />

energy to the crystal — only enough energy to free a single electron from a<br />

bromide (Br – ) ion. Several successive light photons are required to make a<br />

single grain developable (to produce within it, or on it, a stable latent image).<br />

The passage <strong>of</strong> an electron through a grain can transmit hundreds <strong>of</strong> times<br />

more energy than the absorption <strong>of</strong> a light photon. Even though this energy is<br />

used inefficiently the amount is enough to make the grain developable. In fact,<br />

a photoelectron or compton electron can have a fairly long path through a film<br />

emulsion and can render many grains developable. The number <strong>of</strong> grains<br />

exposed per photon interaction varies from one (for X-radiation <strong>of</strong> about 10<br />

keV) to 50 or more (for a 1 MeV photon). Because a grain is completely<br />

exposed by the passage <strong>of</strong> an energetic electron, all X-ray exposures are, as<br />

far as the individual grain is concerned, extremely short. The actual time that<br />

an electron is within a grain depends on the electron velocity, the grain<br />

dimensions and the squareness <strong>of</strong> the hit. A time on the order <strong>of</strong> 10 –13 s is<br />

representative. (In the case <strong>of</strong> light, the exposure time for a single grain is the<br />

interval between the arrival <strong>of</strong> the first photon and the arrival <strong>of</strong> the last<br />

photon required to produce a stable latent image.)<br />

Charlie Chong/ Fion Zhang


Development<br />

Many materials discolor with exposure to light (some kinds <strong>of</strong> wood and<br />

human skin are examples) and could be used to record images. Most <strong>of</strong> these<br />

materials react to light exposure on a 1:1 basis — one photon <strong>of</strong> light alters<br />

one molecule or atom. In the silver halide system <strong>of</strong> radiography, however, a<br />

few atoms <strong>of</strong> photolytically deposited silver can, by development, be made to<br />

trigger the subsequent chemical deposition <strong>of</strong> some 10 9 or 10 10 additional<br />

silver atoms, resulting in an amplification factor on the order <strong>of</strong> 10 9 or greater.<br />

This amplification process can be uniform and reproducible enough for<br />

quantitative radiation measurements. Development is essentially a chemical<br />

reduction in which silver halide is converted to metallic silver. To retain the<br />

photographic image, however, the reaction must be limited largely to those<br />

grains that contain a latent image; that is, to those grains that have received<br />

more than a prescribed minimum radiation exposure.<br />

Charlie Chong/ Fion Zhang


Compounds that can be used as photographic developing agents are those in<br />

which the reduction <strong>of</strong> silver halide to metallic silver is catalyzed (speeded up)<br />

by the presence <strong>of</strong> metallic silver in the latent image. Those compounds that<br />

reduce silver halide, in the absence <strong>of</strong> a catalytic effect by the latent image,<br />

are not suitable developing agents because they produce a uniform overall<br />

density on the processed film.<br />

Charlie Chong/ Fion Zhang


Closing<br />

More information on the radiographic latent image, its formation and<br />

processing are available elsewhere. The correct use <strong>of</strong> film badges is<br />

especially important for safety in the conduct <strong>of</strong> radiographic testing programs<br />

and is discussed in this book’s chapter on radiation safety and elsewhere.<br />

Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Charlie Chong/ Fion Zhang


Good Luck!<br />

Charlie Chong/ Fion Zhang