Model AM-500-EUR Hexagon 110 Hexagon 120 Hexagon 340 37 XR-A 38 XR-A<br />
Display Digits 3 1 / 2<br />
digit, 1999 digits 3¾ digit, 4000 digits 3¾ digit, 4000 digits ¾ digit, 5000 digits 4 digit, 9999 digits 4 digit, 9999 digits<br />
True-RMS measurement AC AC AC+DC<br />
Bar graph • • •<br />
Ranges<br />
Voltage AC 1 mV... 600 V 0.1 mV... 1000 V 0.1 mV... 1000 V 0.01 mV... 1000 V 0.1 mV... 750 V 0.1 mV... 750 V<br />
Basic Accuracy* (1.0% + 3D) (1.5% + 5D) (1.5% + 5D) (0.5% + 3D) (1.2% + 10D) (1.2% + 10D)<br />
Frequency 45...400 Hz 50...500 Hz 50...500 Hz 40 Hz...20 kHz 45 Hz...2 kHz 45 Hz...2 kHz<br />
Voltage DC 1 mV... 600 V 0.1 mV... 1000 V 0.1 mV... 1000 V 0.01 mV... 1000 V 0.1 mV... 1000 V 0.1 mV... 1000 V<br />
Basic Accuracy* (0.8% + 3D) (0.3% + 4D) (0.3% + 4D) (0.08% + 2D) (0.1% + 5D) (0.25% + 5D)<br />
Current AC 0.1 µA...10 A<br />
0.1 µA…10 A<br />
(20A for 30 s)<br />
0.1 µA…10 A<br />
(20A for 30 s)<br />
0.1 µA…10 A<br />
(20A for 30 s) 0.01 µA... 10 A 0.01 µA... 10 A<br />
Basic Accuracy* (1.5% + 3D) (1.5% + 4D) (1.5% + 4D) (0.6% + 3D) (1.5% + 10D) (1.5% + 20D)<br />
Frequency 45...400 Hz 50 Hz...500 Hz 50...500 Hz 40 Hz…1 kHz 45 Hz...1 kHz 45 Hz...1 kHz<br />
Current DC 0.1 µA...10 A<br />
0.1 µA…10 A<br />
(20A for 30 s)<br />
0.1 µA…10 A<br />
(20A for 30 s)<br />
0.1 µA…10 A<br />
(20A for 30 s) 0.01 µA... 10 A 0.01 µA... 10 A<br />
Basic Accuracy* (1.2% + 3D) (1.2% + 3D) (1.2% + 3D) (0.2% + 4D) (0.5% + 10D) (0.5% + 10D)<br />
Resistance 1Ω…20 MΩ 0.1Ω…40 MΩ 0.1Ω…40 MΩ 0.01Ω…50 MΩ 0.1Ω…40 MΩ 0.1Ω…40 MΩ<br />
Diode and continuity <strong>test</strong> • • • • • •<br />
Capacitance 0.01 nF…3000 µF 0.01 nF... 3000 µF 0.01 nF... 9999 µA 0.01 nF... 400.0 µF 0.01 nF... 400.0 µF<br />
Frequency 5 Hz…1 MHz 5 Hz…1 MHz 5 Hz…125 kHz 3.00Hz...10MHz 3.00Hz...10MHz<br />
Temperature -20…+300 °C -50…+1000 °C -20...+1300°C<br />
Range selection<br />
Automatic • • • •<br />
Manual • • • •<br />
Data Hold • • • •<br />
Min/max value memory Max Hold Max Hold • • •<br />
Peak Hold • • •<br />
Relative measurement • • • • •<br />
Data logger/interface - / RS-232 - / RS-232 - / RS-232<br />
Auto Power Off • • • • •<br />
Battery 1 x 9 V 2 x 1.5 V 2 x 1.5 V 1 x 9 V 1 x 9 V 1 x 9 V<br />
Measurement Category CAT III/600 V<br />
CAT III/600V,<br />
CAT II/1000 V<br />
CAT III/600 V,<br />
CAT II/1000 V<br />
CAT IV/600 V,<br />
CAT III/1000 V<br />
CAT III/600V, CAT II/1000V CAT III/600V, CAT II/1000V<br />
Features Battery <strong>test</strong>,<br />
1.5 V/9 V<br />
Acoustic warning signal for<br />
incorrect jack connection<br />
Acoustic warning signal for<br />
incorrect Jack connection<br />
incl. temperature probe<br />
RS-232 interface<br />
Illuminated display<br />
Calibration and adjustment<br />
without opening the device<br />
Software optionally available<br />
Inductance measurement<br />
Acoustic warning signal in<br />
case of incorrect jack connection<br />
logic <strong>test</strong><br />
Magnetic hanger<br />
(MagneGrip TM )<br />
Current loop measurement<br />
(4….20mA) Software<br />
optionally available<br />
Magnetic hanger<br />
(MagneGrip TM )<br />
* = Basic accuracy figures are with regard to the best level of accuracy of the relevant measurement function<br />