TEMPERATURE<br />

2<br />

TEMPERATURE<br />

EXECUTIVE ROOM THERMISTOR AND RTD SENSORS<br />

ST-S*E, ST-S*EW SERIES<br />

DESCRIPTION<br />

The Precon ST-S*E and ST-S*EW Series Executive<br />

Room Sensors provide precision room temperature<br />

sensing for building automation systems. The active<br />

sensing element is made of a highly stable, precision<br />

thermistor material or platinum RTD.<br />

FEATURES<br />

• Lifetime warranty<br />

• ±0.36°F (±0.2°C) thermistor accuracy<br />

• ±1°F (±0.53°C) RTD accuracy<br />

• Wide selection of thermistor and RTD curves<br />

• Vented housing for quick temperature response<br />

• Adaptable with many options<br />

• Traditional beige or white covers<br />

• Durable plastic housing and base plate<br />

• Easy to mount to wall or back box<br />

APPLICATION<br />

The executive enclosure is designed to be wall-mounted<br />

indoors where appearance is important. The separate<br />

base plate may be mounted directly to the drywall<br />

or on a standard electrical outlet box without adapters.<br />

The cover is secured with tamper-resistant hex screws.<br />

Where moisture is a concern, the moistureproof XB<br />

option is required.<br />

SPECIFICATIONS<br />

Sensing element Thermistor (thermal resistor)<br />

RTD (resistance temperature device)<br />

Accuracy<br />

Thermistor ±0.36°F (0.2°C)<br />

RTD ±1°F (0.53°C)<br />

Sensor types available<br />

Thermistor 2.252 k, 3 k, 10 k, 20 k, 100 k�<br />

RTD Platinum 100�, 385 curve<br />

Platinum 1000�, 385 curve<br />

Platinum 1000�, 375 curve<br />

Temp range 35° to 140°F (2° to 60°C)<br />

Temp response<br />

Thermistor Negative temperature coefficient<br />

RTD Positive temperature coefficient<br />

Sensitivity See Sensor Resistance Charts<br />

in the “Technical Reference”<br />

section<br />

OPTIONS<br />

ST-S*E-XA-XME-XPL-XTD<br />

ST-S*EW<br />

• Custom logos<br />

• Setpoint adjustment (400�, 3 k�, 20 k�)<br />

• Moistureproof with 8' (2.44m) lead<br />

• Gray decorator faceplate<br />

• External communication jack<br />

• Internal RJ11 communication jack<br />

• Membrane momentary switch<br />

• Analog temperature display (ST-S3E)<br />

• Digital temperature display (ST-S3E)<br />

• NIST traceable<br />

• LED status lamp<br />

TM<br />

A Division of Kele, Inc.<br />

Stability<br />

Thermistor 0.24°F (0.13°C) over five years<br />

RTD