First connection attributes<br />

Name Description Default<br />

Preallocate<br />

(See page 42.)<br />

RecoveryThreads<br />

(See page 43.)<br />

SMPOptLevel<br />

(See page 44.)<br />

TempSize<br />

(See page 45.)<br />

General connection attributes<br />

Specifies that disk space for the data store<br />

should be preallocated when creating the data<br />

store.<br />

Specifies the number of threads used to rebuild<br />

indexes during recovery.<br />

Specifies the multi-processor optimization<br />

level.<br />

Specifies the size in MB for the temporary<br />

partition of the data store.<br />

False<br />

16 <strong>Oracle</strong> <strong>TimesTen</strong> <strong>In</strong>-<strong>Memory</strong> <strong>Database</strong> <strong>API</strong> <strong>and</strong> <strong>SQL</strong> <strong>Reference</strong> <strong>Guide</strong><br />

1<br />

0 (Minimal use of<br />

synchronization<br />

primitives)<br />

The default size is<br />

determined from<br />

the PermSize<br />

value.<br />

Name Description Default<br />

ConnectionName<br />

(See page 46.)<br />

Diagnostics<br />

(See page 46.)<br />

DurableCommits<br />

(See page 48.)<br />

ExclAccess<br />

(See page 49.)<br />

Isolation<br />

(See page 50.)<br />

LockLevel<br />

(See page 51.)<br />

LockWait<br />

(See page 52.)<br />

Specifie.s whether symbolic name for the data<br />

source<br />

Specifies whether diagnostic messages are<br />

generated.<br />

Specifies that commit operations should write<br />

log records to disk.<br />

Specifies that the connection should have<br />

exclusive access to the data store.<br />

Specifies whether the isolation level is read<br />

committed or serializable.<br />

Specifies whether the connection should use<br />

row-level locking (value = 0) or data store-level<br />

locking (value = 1).<br />

Allows an application to configure the lock wait<br />

interval for the connection.<br />

The process<br />

name<br />

1 (Messages are<br />

generated.)<br />

1 (Writes records<br />

to disk)<br />

False<br />

1 (Read<br />

committed)<br />

Row-level<br />

locking<br />

10 seconds