Customer : ENV<br />

Type : A<strong>320</strong><br />

Rev. Date : Nov 01, 2016<br />

<strong>51</strong>-<strong>21</strong>-<strong>11</strong> Application of Protective Treatment to Metal Parts<br />

Manual : <strong>SRM</strong><br />

Selected effectivity :<br />

SOLUTION<br />

FAC<strong>TO</strong>R WHEN YOU<br />

MEASURE IN (mm or cm)<br />

FAC<strong>TO</strong>R WHEN YOU<br />

MEASURE IN (in)<br />

Cadmium alkaline solution 0.488 80<br />

Cadmium acid solution 0.488 80<br />

Table 004 - Specific Plating Factor<br />

- Example: You have to plate an area of 25 cm² (3.875 in²) with cadmium alkaline solution.<br />

The required thickness is 0.015 mm. The correct ampere-hours setting is: 0.488 x 0.015 x<br />

25 = 0.183 ampere-hours<br />

- Example: You have to plate the same area with the same thickness, but you measure in<br />

inches. The thickness is 0.0006 in and the area has the size of 3.87 sq.in Determine the<br />

correct number of ampere-hours as follows: 80 x 0.0006 x 3.87 = 0.183 ampere-hours<br />

4 Inspection<br />

The cadmium deposit must be fine grain, smooth, and free from blisters, pitting, burns and<br />

other defects. Ensure that the cadmium deposit has good adherence to the metal surface.<br />

Check this with an adhesive tape. Put a strip of adhesive tape onto the treated surface and<br />

draw it quickly away. The adhesive tape must be free from cadmium particles.<br />

5 Procedure for non stainless steel<br />

a<br />

b<br />

Remove all grease from the repair area with a clean cloth soaked in trichloroethane<br />

(Material No. <strong>11</strong>-026 ).<br />

When the cleaning agent has evaporated, mask off all areas which are not to be treated.<br />

WARNING: CLEANING AND DEOXIDIZING SOLUTION IS HARMFUL.<br />

c<br />

d<br />

With a prepared tampon apply the cleaning and deoxidizing solution (Item 1 in the<br />

Table of Subsidiary Materials). Do this at cathodic plating polarity (see manufacturer's<br />

instructions) and 10 to 12 volts. Move the tampon in contact and over the surface until<br />

you get a regular clean surface which is free from water breaks. This should take about 5<br />

to 10 seconds per square inch (6.5 cm² (1.007 in²)).<br />

Rinse the area with clean cold running water.<br />

WARNING: CADMIUM ALKALINE SOLUTION IS DANGEROUS.<br />

e<br />

With a prepared tampon apply the cadmium alkaline solution (Item 9 in the Table of<br />

Subsidiary Materials). Do this at cathodic plating polarity and 8 to 12 volts. Move the<br />

tampon in contact with and over the surface until you get the required thickness. You<br />

should move the tampon at a speed of approximately 10 to 38 cm (4 to 15 in) per<br />

second.<br />

NOTE: For unspecified thickness, the deposit must average between 0.015 mm (0.0006<br />

in) and a minimum of 0.01 mm (0.0004 in), refer to Paragraph 2.B.(1).(d).3 .<br />

f<br />

g<br />

Rinse the area with clean cold running water.<br />

Abrade slightly the treated surface with a Scotch-brite pad or aluminum oxide and<br />

cotton wool. It will brighten the cadmium deposit before passivation and improve its<br />

appearance.<br />

WARNING: CADMIUM/ZINC PASSIVATING SOLUTION IS HARMFUL.<br />