ATEX compliant - SMC
ATEX compliant - SMC
ATEX compliant - SMC
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>ATEX</strong> Compliant Reed Switch/Direct Mounting<br />
D-A90(V)/D-A93(V)-588<br />
Grommet<br />
Note) All other specifications<br />
(dimensions, drawings, etc.)<br />
are the same as the non <strong>ATEX</strong> type.<br />
Internal Circuit<br />
( ): If not applicable for IEC Standard<br />
D-A90<br />
D-A90V<br />
D-A93, D-A93V<br />
Note) qIn the case operation load is an inductive load.<br />
wIn the case the wiring length to load is “>” 5m.<br />
Be sure to use the auto switch with the contact protection<br />
box in any case mentioned above.<br />
46<br />
Reed switch<br />
Reed switch<br />
LED<br />
Resistance<br />
Zener diode<br />
Contact<br />
protective<br />
box<br />
CD-P11<br />
CD-P12<br />
Brown(Red) Contact<br />
protective<br />
box<br />
Blue(Black)<br />
CD-P11<br />
CD-P12<br />
OUT(±)<br />
Brown(Red)<br />
to<br />
OUT( )<br />
Blue(Black)<br />
±<br />
OUT(+)<br />
Brown(Red)<br />
to<br />
OUT(–)<br />
Blue(Black)<br />
Specifications PLC: Programmable Logic Controller<br />
D-A90, D-A90V (Without indicator light)<br />
Auto swich modle number<br />
<strong>ATEX</strong> Category<br />
Application<br />
Load voltage<br />
Max. load current<br />
Contact protection circuit<br />
Internal resistance<br />
D-A93, D-A93V (With indicator light)<br />
Auto switch model number<br />
D-A93, D-A93V<br />
<strong>ATEX</strong> Category<br />
Application<br />
Load voltage<br />
Max. load current and<br />
load current range<br />
Contact protection circuit<br />
Internal voltage drop<br />
Indicator light<br />
Lead wire<br />
D-A90(V)/D-A93(V) Oilproof vinyl heavy insulation cable, ø2.7, 0.18mm 2 X 2cores (Brown, Blue)<br />
Dimensions<br />
D-A90, D-A90V<br />
IC circuit/Relay/PLC<br />
AC<br />
AC<br />
24V DC or less<br />
48V DC or less<br />
50mA<br />
40mA<br />
None<br />
1Ω or less (Including 3m lead wire)<br />
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67<br />
Relay/PLC<br />
24V DC<br />
5 to 40mA<br />
None<br />
≤ 2.4V (up to 20mA)/≤ 3V (up to 40mA)<br />
ON: When red light emitting diode<br />
This category 3 type autoswitch can only be used in zones 2 and 22.<br />
93<br />
90<br />
D-A<br />
Switch No.<br />
With indicator lamp<br />
Without indicator lamp<br />
No number<br />
V<br />
II 3GD EEx nA II T5 X -10°C≤Ta≤+60°C IP67<br />
Electrical entry<br />
In line<br />
Perpendicular<br />
-588<br />
Lead wire length<br />
No number<br />
L<br />
Z<br />
Suffix for<br />
<strong>ATEX</strong> certified CAT.3<br />
0.5m<br />
3m<br />
5m (Except D-A90�)