D-R731/R732<br />

Reed switch Reed switch<br />

D-���2<br />

Left hand mounting<br />

Emitting diode<br />

Resistance<br />

Zener<br />

diode<br />

D-R801/R802<br />

Brown<br />

(Red)<br />

Blue<br />

(Black)<br />

Contact<br />

protection<br />

box<br />

CD-P11<br />

CD-P12<br />

Contact<br />

protection<br />

box<br />

CD-P11<br />

CD-P12<br />

D-���1<br />

Auto switch internal circuit<br />

( ): Before IEC standard<br />

50<br />

Grommet<br />

Lead Wire: In-line<br />

Reed Switch/Direct Mounting Type<br />

D-R73/D-R80<br />

Right hand mounting<br />

OUT (±)<br />

Brown (Red)<br />

~<br />

OUT (±)<br />

Blue (Black)<br />

OUT (+)<br />

Brown (Red)<br />

~<br />

OUT (–)<br />

Blue (Black)<br />

Applicable rotary actuator series<br />

Series<br />

CDRB1<br />

CDRBU<br />

MDSUB<br />

Auto switch specificatoins<br />

Size<br />

20, 30, 50, 80, 100<br />

20, 30<br />

7, 20<br />

D-R73� (With indicator light)<br />

PLC: Programmable Logic Controller<br />

D-R80� (Without indicator light)<br />

Auto switch model no. D-R731/D-R732 D-R801/D-R802<br />

Applicable load<br />

Relay, PLC Relay, IC circuit, PLC<br />

Load voltage 100V AC 24V DC<br />

AC<br />

24V DC or less<br />

AC 48V DC<br />

AC<br />

100V DC<br />

Max. load current and<br />

load current range<br />

Dimensions<br />

5 to 20mA<br />

5 to 40mA 50mA<br />

Contact protection circuit None<br />

Internal voltage drop 2.4V or less<br />

Indicator light ON: Red light emitting diode<br />

40mA<br />

None<br />

0<br />

None<br />

Lead wire Oil proof vinyl heavy insulation cable 0.2mm 2 , X2 wire (Brown, blue) 0.5m<br />

20mA<br />

D-R731: Right hand mounting D-R732: Left hand mounting<br />

Most sensitive position<br />

Most sensitive position<br />

D-R801: Right hand mounting D-R802: Left hand mounting<br />

Most sensitive position<br />