The 0.8 multiplier is necessary because the whole fuel consumption and thus part of its<br />
carbon emissions is turned into the production of heat generated by power plants. The emission<br />
associated with the production of this heat is 20%, according to the most recent data (from 2012).<br />
The Romanian Energy Regulatory Authority (ANRE) does not report the fuel type and<br />
quantity used by specific power plants, only the total energetic value of the different fuels used in<br />
the whole electricity sector in a given year. Thus Equation 2 reduces to:<br />
Where<br />
Equation 3<br />
FCE i : total energy value of “i” type of energy resource used in the national electricity generation<br />
industry for the given year [TJ/y];<br />
EGF i : electrical power fed into the grid by using “i” type fossil fuel for the given year [MWh/y].<br />
Emission reductions<br />
According to the <strong>CSG</strong> Standard’s “Solar, wind and hydro-power energy-based grid-attachable<br />
electricity production methodology” version 2.1, the following formula shall be used to calculate<br />
emission reductions thanks to the Project Activity:<br />
Where:<br />
ER: annual emission reductions; [tCO 2 e/y];<br />
BE: baseline emissions [tCO 2 e/y];<br />
ER = BE - PE<br />
Equation 4<br />
PE: GHG emissions from fossil fuel consumption [tCO 2 e/y].<br />
2.6.2. Data and parameters that are available at the validation stage<br />
Table 6. EGF i<br />
Data / Parameter:<br />
EGF i<br />
Data unit:<br />
MWh/y<br />
Description:<br />
Annual net energy delivered to the Romanian<br />
Electricity Grid by using “i” type fossil fuel<br />
Source of data used:<br />
Romanian Energy Regulatory Authority (ANRE)<br />
Value applied: Details in Annex 2<br />
14