You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Product data<br />
Shaft seal<br />
The operating range of the shaft seal depends on<br />
operating pressure, pump type, type of shaft seal and<br />
liquid temperature.<br />
<strong>MTR</strong>(E)<br />
p<br />
[psi]<br />
400<br />
300<br />
200<br />
100<br />
Shaft seal Description<br />
HUUV<br />
<strong>MTR</strong> pumps with EPDM elastomers in the shaft seals<br />
(HUUE) can run in the temperature range from 194 °F<br />
to 248 °F. Closed strap nuts with o-rings and plugging<br />
of the shaft seal drain hole may also be required at<br />
temperatures above 212 °F (see page 31).<br />
<strong>MTC</strong><br />
0<br />
p<br />
[psi]<br />
400<br />
300<br />
200<br />
100<br />
0<br />
O-ring seal (cartridge type), balanced,<br />
tungsten carbide/tungstencarbide,<br />
FKM<br />
Shaft seal Description<br />
AUUV<br />
HUUV<br />
0 20 40 60 80 100 120 140 160 180 200 220<br />
T [°F]<br />
AUUV<br />
O-ring seal with fixed seal<br />
driver, tungsten carbide/tungsten<br />
carbide, FKM<br />
TM03 4270 2006<br />
Temperature range<br />
[°F]<br />
+14 °F to 194 °F<br />
0 20 40 60 80 100 120 140 160 180 200 220<br />
T [°F]<br />
TM03 4271 2006<br />
Temperature range<br />
[°F]<br />
+14 °F to 194 °F<br />
Ambient temperature<br />
<strong>MTR</strong>(E), <strong>MTC</strong>, <strong>MTA</strong><br />
Maximum ambient temperature +104 °F (+40 °C).<br />
If the ambient temperature exceeds +104 °F (+40 °C) or<br />
if the motor is located 3280 ft (1000 m) above sea level,<br />
the motor output (P 2) must be reduced due to the low<br />
density and consequently low cooling effect of the air.<br />
In such cases, it may be necessary to use a motor with<br />
a higher output.<br />
Key<br />
P2<br />
[%]<br />
100<br />
2<br />
90<br />
80<br />
70<br />
60<br />
50<br />
1<br />
60 80 100 120 140 160 180<br />
T [°F]<br />
3280 7382 11483 15584 ft<br />
Fig. 5 Relationship between motor output (P2 ) and<br />
ambient temperature/altitude<br />
Pos. Description<br />
1 NEMA Energy Efficient motors<br />
2 NEMA Premium Efficiency motors<br />
Example: From the above figure and key appears that<br />
P 2 must be reduced to 88 % when a pump with a NEMA<br />
Premium Efficiency, ML motor is installed 15584 feet<br />
above sea level. At an ambient temperature of 167 °F,<br />
P 2 of an Energy Efficient motor must be reduced to<br />
74 % of rated output.<br />
Maximum operating pressure<br />
Immersible Pump Model<br />
Maximum Permissible<br />
Operating Pressure<br />
NPT Threads ANSI Flange<br />
<strong>MTR</strong>(I) 1s --> <strong>MTR</strong>(I) 5 362 psi --<br />
<strong>MTR</strong>(I) 10 --> <strong>MTR</strong>(I) 20 362 psi --<br />
<strong>MTR</strong>(I) 32-2/1-1 --> <strong>MTR</strong>(I) 32-5 -- 232 psi<br />
<strong>MTR</strong>(I) 32-6 --> <strong>MTR</strong>(I) 32-8 -- 362 psi<br />
<strong>MTR</strong>(I) 32-9 --> <strong>MTR</strong>(I) 32-11-2 -- 435 psi<br />
<strong>MTR</strong>(I) 45-2/1 --> <strong>MTR</strong>(I) 45-3 -- 232 psi<br />
<strong>MTR</strong>(I) 45-4 --> <strong>MTR</strong>(I) 45-5 -- 362 psi<br />
<strong>MTR</strong>(I) 64-2/1-1 --> <strong>MTR</strong>(I) 64-4-2 -- 232 psi<br />
<strong>MTC</strong> 2 --> <strong>MTC</strong> 4 116 psi --<br />
<strong>MTA</strong> 3 15 psi --<br />
<strong>MTA</strong> 4 20 psi --<br />
<strong>MTA</strong>D 7 20 psi --<br />
TM03 4272 2006<br />
13