Product data<br />

Shaft seal<br />

The operating range of the shaft seal depends on<br />

operating pressure, pump type, type of shaft seal and<br />

liquid temperature.<br />

<strong>MTR</strong>(E)<br />

p<br />

[psi]<br />

400<br />

300<br />

200<br />

100<br />

Shaft seal Description<br />

HUUV<br />

<strong>MTR</strong> pumps with EPDM elastomers in the shaft seals<br />

(HUUE) can run in the temperature range from 194 °F<br />

to 248 °F. Closed strap nuts with o-rings and plugging<br />

of the shaft seal drain hole may also be required at<br />

temperatures above 212 °F (see page 31).<br />

<strong>MTC</strong><br />

0<br />

p<br />

[psi]<br />

400<br />

300<br />

200<br />

100<br />

0<br />

O-ring seal (cartridge type), balanced,<br />

tungsten carbide/tungstencarbide,<br />

FKM<br />

Shaft seal Description<br />

AUUV<br />

HUUV<br />

0 20 40 60 80 100 120 140 160 180 200 220<br />

T [°F]<br />

AUUV<br />

O-ring seal with fixed seal<br />

driver, tungsten carbide/tungsten<br />

carbide, FKM<br />

TM03 4270 2006<br />

Temperature range<br />

[°F]<br />

+14 °F to 194 °F<br />

0 20 40 60 80 100 120 140 160 180 200 220<br />

T [°F]<br />

TM03 4271 2006<br />

Temperature range<br />

[°F]<br />

+14 °F to 194 °F<br />

Ambient temperature<br />

<strong>MTR</strong>(E), <strong>MTC</strong>, <strong>MTA</strong><br />

Maximum ambient temperature +104 °F (+40 °C).<br />

If the ambient temperature exceeds +104 °F (+40 °C) or<br />

if the motor is located 3280 ft (1000 m) above sea level,<br />

the motor output (P 2) must be reduced due to the low<br />

density and consequently low cooling effect of the air.<br />

In such cases, it may be necessary to use a motor with<br />

a higher output.<br />

Key<br />

P2<br />

[%]<br />

100<br />

2<br />

90<br />

80<br />

70<br />

60<br />

50<br />

1<br />

60 80 100 120 140 160 180<br />

T [°F]<br />

3280 7382 11483 15584 ft<br />

Fig. 5 Relationship between motor output (P2 ) and<br />

ambient temperature/altitude<br />

Pos. Description<br />

1 NEMA Energy Efficient motors<br />

2 NEMA Premium Efficiency motors<br />

Example: From the above figure and key appears that<br />

P 2 must be reduced to 88 % when a pump with a NEMA<br />

Premium Efficiency, ML motor is installed 15584 feet<br />

above sea level. At an ambient temperature of 167 °F,<br />

P 2 of an Energy Efficient motor must be reduced to<br />

74 % of rated output.<br />

Maximum operating pressure<br />

Immersible Pump Model<br />

Maximum Permissible<br />

Operating Pressure<br />

NPT Threads ANSI Flange<br />

<strong>MTR</strong>(I) 1s --> <strong>MTR</strong>(I) 5 362 psi --<br />

<strong>MTR</strong>(I) 10 --> <strong>MTR</strong>(I) 20 362 psi --<br />

<strong>MTR</strong>(I) 32-2/1-1 --> <strong>MTR</strong>(I) 32-5 -- 232 psi<br />

<strong>MTR</strong>(I) 32-6 --> <strong>MTR</strong>(I) 32-8 -- 362 psi<br />

<strong>MTR</strong>(I) 32-9 --> <strong>MTR</strong>(I) 32-11-2 -- 435 psi<br />

<strong>MTR</strong>(I) 45-2/1 --> <strong>MTR</strong>(I) 45-3 -- 232 psi<br />

<strong>MTR</strong>(I) 45-4 --> <strong>MTR</strong>(I) 45-5 -- 362 psi<br />

<strong>MTR</strong>(I) 64-2/1-1 --> <strong>MTR</strong>(I) 64-4-2 -- 232 psi<br />

<strong>MTC</strong> 2 --> <strong>MTC</strong> 4 116 psi --<br />

<strong>MTA</strong> 3 15 psi --<br />

<strong>MTA</strong> 4 20 psi --<br />

<strong>MTA</strong>D 7 20 psi --<br />

TM03 4272 2006<br />