Microduct DB 10/6 - recommended cable outer diameter from 2,0 <strong>to</strong> 4,5 mm<br />

Parameter Value Standard, conditions<br />

Outer diameter (OD) 10±0,1 mm Internal standard<br />

Inner diameter (ID) min. 5,9 mm Internal standard<br />

Wall thickness (WT) min. 1,9 mm Internal standard<br />

Blown ball test (BB-test) pass Internal standard, ball diameter 5,0 mm<br />

Burst pressure min. 70 bar EN ISO 1167-1, 2<br />

Crush - residual deformation max. 15% OD = max. 1,5 mm EN 60794-1-2, E3, sample 200 mm, aktive 100 mm,<br />

force 2100 N, 3 mm/min., aktion 60 s, recovery 20 s<br />

Bending stiffness min. 0,19 N.m 2 Internal standard<br />

Standard Dimension Ratio (SDR = OD/WT) 5 -<br />

Weight 47,5 kg/km -<br />

Installation tensile force max. 680 N -<br />

Minimum bending 100 mm -<br />

Microduct DB 12/8 - recommended cable outer diameter from 4,0 <strong>to</strong> 6,5 mm<br />

Parameter Value Standard, conditions<br />

Outer diameter (OD) 12±0,1 mm Internal standard<br />

Inner diameter (ID) min. 7,9 mm Internal standard<br />

Wall thickness (WT) min. 1,9 mm Internal standard<br />

Blown ball test (BB-test) pass Internal standard, ball diameter 6,5 mm<br />

Burst pressure min. 60 bar EN ISO 1167-1, 2<br />

Crush - residual deformation max. 15% OD = max. 1,8 mm EN 60794-1-2, E3, sample 200 mm, aktive 100 mm,<br />

force 1680 N, 3 mm/min., aktion 60 s, recovery 20 s<br />

Bending stiffness min. 0,36 N.m 2 Internal standard<br />

Standard Dimension Ratio (SDR = OD/WT) 6 -<br />

Weight 59 kg/km -<br />

Installation tensile force max. 840 N -<br />

Minimum bending 120 mm -<br />

Microduct DB 14/10 - recommended cable outer diameter from 5,0 <strong>to</strong> 8,5 mm<br />

Parameter Value Standard, conditions<br />

Outer diameter (OD) 14±0,1 mm Internal standard<br />

Inner diameter (ID) min. 9,9 mm Internal standard<br />

Wall thickness (WT) min. 1,9 mm Internal standard<br />

Blown ball test (BB-test) pass Internal standard, ball diameter 8,0 mm<br />

Burst pressure min. 50 bar EN ISO 1167-1, 2<br />

Crush - residual deformation max. 15% OD = max. 2,1 mm EN 60794-1-2, E3, sample 200 mm, aktive 100 mm,<br />

force 1400 N, 3 mm/min., aktion 60 s, recovery 20 s<br />

Bending stiffness min. 0,61 N.m 2 Internal standard<br />

Standard Dimension Ratio (SDR = OD/WT) 7 -<br />

Weight 72 kg/km -<br />

Installation tensile force max. 1010 N -<br />

Minimum bending 140 mm -<br />

Microduct DB 16/12 - recommended cable outer diameter from 7,0 <strong>to</strong> 10,0 mm<br />

Parameter Value Standard, conditions<br />

Outer diameter (OD) 16±0,1 mm Internal standard<br />

Inner diameter (ID) min. 11,9 mm Internal standard<br />

Wall thickness (WT) min. 1,9 mm Internal standard<br />

Blown ball test (BB-test) pass Internal standard, ball diameter 10,0 mm<br />

Burst pressure min. 40 bar EN ISO 1167-1, 2<br />

Crush - residual deformation max. 15% OD = max. 2,4 mm EN 60794-1-2, E3, sample 200 mm, aktive 100 mm,<br />

force 1200 N, 3 mm/min., aktion 60 s, recovery 20 s<br />

Bending stiffness min. 0,94 N.m 2 Internal standard<br />

Standard Dimension Ratio (SDR = OD/WT) 8 -<br />

Weight 84 kg/km -<br />

Installation tensile force max. 1150 N -<br />

Minimum bending 160 mm -<br />

Microduct 7/4 (for cables from 1,0 - 2,5 mm) Art. No. 2735188<br />

Microduct 10/6 (for cables from 2,0 - 4,5 mm) Art. No. 2735189<br />

Microduct 12/8 (for cables from 4,0 - 6,5 mm) Art. No. 2735190<br />

Microduct 14/10 (for cables from 5,0 - 8,5 mm) Art. No. 2735191<br />

Microduct 16/12 (for cables from 7,0 - 10,0 mm) Art. No. 2735192