A-DQ(BN)2Y GGT - Outdoor cable, loose tube construction, D23-S20<br />
outdoor cable<br />
rodent protection<br />
metal-free<br />
longitudinally<br />
water-tight<br />
A-DQ(BN)2Y GGT 2x12E9/125 Art. No. 2035134<br />
A-DQ(BN)2Y GGT 4x12E9/125 Art. No. 2035135<br />
A-DQ(BN)2Y GGT 6x12E9/125 Art. No. 2035136<br />
A-DQ(BN)2Y GGT 8x12E9/125 Art. No. 2035137<br />
A-DQ(BN)2Y GGT 10x12E9/125 Art. No. 2035138<br />
A-DQ(BN)2Y GGT 12x12E9/125 Art. No. 2035139<br />
A-DQ(BN)2Y GGT 8x24 E9/125 Art. No. 2035140<br />
A-DQ(BN)2Y GGT 18x24E9/125 Art. No. 2035141<br />
Type number of number of tubes number of tube-Ø tensile strength outer-Ø weight<br />
<strong>fiber</strong>s/tube + fillers <strong>fiber</strong>s approx. mm max. N approx. mm approx. kg/km<br />
A-DQ(BN)2Y GGT 2x12E9/125 12 2 + 3 24 2,3 3500 13,2 141,7<br />
A-DQ(BN)2Y GGT 4x12E9/125 12 4 + 1 48 2,3 3500 13,2 145,3<br />
A-DQ(BN)2Y GGT 6x12E9/125 12 6 + 0 72 2,3 3500 13,5 160,0<br />
A-DQ(BN)2Y GGT 8x12E9/125 12 8 + 0 96 2,3 3500 14,8 182,5<br />
A-DQ(BN)2Y GGT 10x12E9/125 12 10 + 0 120 2,3 3500 16,3 214,0<br />
A-DQ(BN)2Y GGT 12x12E9/125 12 12 + 0 144 2,3 3500 18,0 251,0<br />
A-DQ(BN)2Y GGT 8x24E9/125 24 8 + 0 192 2,3 3500 16,5 221,8<br />
A-DQ(BN)2Y GGT 18x24E9/125 24 18 + 0 432 2,3 3500 20,5 335,4<br />
Stranded loose tube cable for outdoor applications. Highly rodent protected by 2 layers of glass rovings.<br />
This cable is used as higher <strong>fiber</strong> count data cable in distribution networks and withstands environments with high mechanical demands.<br />
Fibers according ITU-T G.652.D<br />
Construction<br />
FRP-central element<br />
loose tubes, SZ-cabling (if necessary with fillers)<br />
dry filled cable core<br />
strength members (glass-rovings)<br />
ripcord<br />
PE-sheath, UV-resistant, black with two orange longitudinal stripes<br />
Fiber colours<br />
1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise<br />
13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.)<br />
Tube colours<br />
1: red<br />
2: green<br />
o<strong>the</strong>rs: nature or white<br />
Filler colours<br />
black<br />
Laying<br />
usable for fixed laying in ducts or conduits and outdoors<br />
Marking<br />
double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing<br />
Technical Data<br />
tensile strength:<br />
compressive strength:<br />
impact strength:<br />
<strong>to</strong>rsion:<br />
kink, cable:<br />
kink, loose tube:<br />
min. bending radius:<br />
temperature range:<br />
water penetration:<br />
according <strong>to</strong> IEC 60794-1-E1<br />
according <strong>to</strong> IEC 60794-1-E3 | value: 3000 N/10 cm<br />
according <strong>to</strong> IEC 60794-1-E4 | value: 10 Nm<br />
according <strong>to</strong> IEC 60794-1-E7 | value: 5 cycles ±1 turn<br />
according <strong>to</strong> IEC 60794-1-E10 | value: The cables do not form a kink when a loop is drawn <strong>to</strong>ge<strong>the</strong>r <strong>to</strong> a<br />
diameter 12 times <strong>the</strong> cable nominal diameter.<br />
according <strong>to</strong> IEC 60794-1-E16 | value: The loose tubes do not kink.<br />
according <strong>to</strong> IEC 60794-1-E11 | value: R = 20 x D (cable outer diameter)<br />
according <strong>to</strong> IEC 60794-1-F1<br />
s<strong>to</strong>rage and transport: -40°C up <strong>to</strong> +70°C<br />
laying:<br />
-5°C up <strong>to</strong> +60°C<br />
operation:<br />
-30°C up <strong>to</strong> +70°C<br />
according <strong>to</strong> IEC 60794-1-F5 | value: No water on free end.