12.08.2017 Views

opdisys-fiber-to-the-home-solution

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A-DQ(BN)2Y GGT - Outdoor cable, loose tube construction, D23-S20<br />

outdoor cable<br />

rodent protection<br />

metal-free<br />

longitudinally<br />

water-tight<br />

A-DQ(BN)2Y GGT 2x12E9/125 Art. No. 2035134<br />

A-DQ(BN)2Y GGT 4x12E9/125 Art. No. 2035135<br />

A-DQ(BN)2Y GGT 6x12E9/125 Art. No. 2035136<br />

A-DQ(BN)2Y GGT 8x12E9/125 Art. No. 2035137<br />

A-DQ(BN)2Y GGT 10x12E9/125 Art. No. 2035138<br />

A-DQ(BN)2Y GGT 12x12E9/125 Art. No. 2035139<br />

A-DQ(BN)2Y GGT 8x24 E9/125 Art. No. 2035140<br />

A-DQ(BN)2Y GGT 18x24E9/125 Art. No. 2035141<br />

Type number of number of tubes number of tube-Ø tensile strength outer-Ø weight<br />

<strong>fiber</strong>s/tube + fillers <strong>fiber</strong>s approx. mm max. N approx. mm approx. kg/km<br />

A-DQ(BN)2Y GGT 2x12E9/125 12 2 + 3 24 2,3 3500 13,2 141,7<br />

A-DQ(BN)2Y GGT 4x12E9/125 12 4 + 1 48 2,3 3500 13,2 145,3<br />

A-DQ(BN)2Y GGT 6x12E9/125 12 6 + 0 72 2,3 3500 13,5 160,0<br />

A-DQ(BN)2Y GGT 8x12E9/125 12 8 + 0 96 2,3 3500 14,8 182,5<br />

A-DQ(BN)2Y GGT 10x12E9/125 12 10 + 0 120 2,3 3500 16,3 214,0<br />

A-DQ(BN)2Y GGT 12x12E9/125 12 12 + 0 144 2,3 3500 18,0 251,0<br />

A-DQ(BN)2Y GGT 8x24E9/125 24 8 + 0 192 2,3 3500 16,5 221,8<br />

A-DQ(BN)2Y GGT 18x24E9/125 24 18 + 0 432 2,3 3500 20,5 335,4<br />

Stranded loose tube cable for outdoor applications. Highly rodent protected by 2 layers of glass rovings.<br />

This cable is used as higher <strong>fiber</strong> count data cable in distribution networks and withstands environments with high mechanical demands.<br />

Fibers according ITU-T G.652.D<br />

Construction<br />

FRP-central element<br />

loose tubes, SZ-cabling (if necessary with fillers)<br />

dry filled cable core<br />

strength members (glass-rovings)<br />

ripcord<br />

PE-sheath, UV-resistant, black with two orange longitudinal stripes<br />

Fiber colours<br />

1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise<br />

13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.)<br />

Tube colours<br />

1: red<br />

2: green<br />

o<strong>the</strong>rs: nature or white<br />

Filler colours<br />

black<br />

Laying<br />

usable for fixed laying in ducts or conduits and outdoors<br />

Marking<br />

double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing<br />

Technical Data<br />

tensile strength:<br />

compressive strength:<br />

impact strength:<br />

<strong>to</strong>rsion:<br />

kink, cable:<br />

kink, loose tube:<br />

min. bending radius:<br />

temperature range:<br />

water penetration:<br />

according <strong>to</strong> IEC 60794-1-E1<br />

according <strong>to</strong> IEC 60794-1-E3 | value: 3000 N/10 cm<br />

according <strong>to</strong> IEC 60794-1-E4 | value: 10 Nm<br />

according <strong>to</strong> IEC 60794-1-E7 | value: 5 cycles ±1 turn<br />

according <strong>to</strong> IEC 60794-1-E10 | value: The cables do not form a kink when a loop is drawn <strong>to</strong>ge<strong>the</strong>r <strong>to</strong> a<br />

diameter 12 times <strong>the</strong> cable nominal diameter.<br />

according <strong>to</strong> IEC 60794-1-E16 | value: The loose tubes do not kink.<br />

according <strong>to</strong> IEC 60794-1-E11 | value: R = 20 x D (cable outer diameter)<br />

according <strong>to</strong> IEC 60794-1-F1<br />

s<strong>to</strong>rage and transport: -40°C up <strong>to</strong> +70°C<br />

laying:<br />

-5°C up <strong>to</strong> +60°C<br />

operation:<br />

-30°C up <strong>to</strong> +70°C<br />

according <strong>to</strong> IEC 60794-1-F5 | value: No water on free end.