Patch cable PC LC/APC simplex, 2 mm Characteristics of LC/APC simplex: • user-friendly audible latch <strong>to</strong> indicate proper mating • push-pull locking • plastic housing with zirconia ferrule • standard IEC 61754-20 • insertion loss (IL) for SM (typical) average value
Fiber optic cable A-DQ(BN)2Y CT - Outdoor cable, center unitube, D35-S15 outdoor cable rodent protection metal-free longitudinally water-tight A-DQ(BN)2Y CT 12E9/125 Art. No. 2035132 A-DQ(BN)2Y CT 24E9/125 Art. No. 2035133 Type number of numbers of tube-Ø tenisle strength outer-Ø weight <strong>fiber</strong>s / tube <strong>fiber</strong>s approx. mm max. N approx. mm approx. kg/km A-DQ(BN)2Y CT 12E9/125 12 12 3,5 2000 8,5 72,8 A-DQ(BN)2Y CT 24E9/125 24 24 3,5 2000 8,5 73,7 Central loose tube cable for outdoor applications. Rodent protected by glass rovings. This cable is used as low <strong>fiber</strong> count data cable in distribution networks and meets <strong>the</strong> demands of outdoor environments. Fibers according ITU-T G.652.D Construction center unitube strength members (aramide yarns) PE-sheath, UV-resistant, black with two orange longitudinal stripes Fiber colours 1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise 13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.) Tube colour red Laying usable for fixed laying in ducts or conduits and outdoors Marking double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing Technical Data tensile strength: compressive strength: impact strength: <strong>to</strong>rsion: kink, cable: kink, tube: min. bending radius: temperature range: water penetration: according <strong>to</strong> IEC 60794-1-E1 according <strong>to</strong> IEC 60794-1-E3 | value: 3000 N/10 cm according <strong>to</strong> IEC 60794-1-E4 | value: 5 Nm according <strong>to</strong> IEC 60794-1-E7 | value: 5 cycles ±1 turn according <strong>to</strong> IEC 60794-1-E10 | value: The cables do not form a kink when a loop is drawn <strong>to</strong>ge<strong>the</strong>r <strong>to</strong> a diameter of 100 mm. according <strong>to</strong> IEC 60794-1-E16 | value: The loose tubes do not kink. according <strong>to</strong> IEC 60794-1-E11 | value: R = 20 x D (cable outer diameter) according <strong>to</strong> IEC 60794-1-F1 s<strong>to</strong>rage and transport: -40°C up <strong>to</strong> +70°C laying: -5°C up <strong>to</strong> +60°C operation: -25°C up <strong>to</strong> +70°C according <strong>to</strong> IEC 60794-1-F5 | value: No water on free end. OPDISYS ® Fiber <strong>to</strong> <strong>the</strong> Home - Solution • 02/2016 • © by Pengg Kabel GmbH • Technische Änderungen vorbehalten 7