Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Fiber optic cable<br />
A-DQ(BN)2Y CT - Outdoor cable, center unitube, D35-S15<br />
outdoor cable<br />
rodent protection<br />
metal-free<br />
longitudinally<br />
water-tight<br />
A-DQ(BN)2Y CT 12E9/125 Art. No. 2035132<br />
A-DQ(BN)2Y CT 24E9/125 Art. No. 2035133<br />
Type number of numbers of tube-Ø tenisle strength outer-Ø weight<br />
<strong>fiber</strong>s / tube <strong>fiber</strong>s approx. mm max. N approx. mm approx. kg/km<br />
A-DQ(BN)2Y CT 12E9/125 12 12 3,5 2000 8,5 72,8<br />
A-DQ(BN)2Y CT 24E9/125 24 24 3,5 2000 8,5 73,7<br />
Central loose tube cable for outdoor applications. Rodent protected by glass rovings.<br />
This cable is used as low <strong>fiber</strong> count data cable in distribution networks and meets <strong>the</strong> demands of outdoor environments. Fibers according<br />
ITU-T G.652.D<br />
Construction<br />
center unitube<br />
strength members (aramide yarns)<br />
PE-sheath, UV-resistant, black with two orange longitudinal stripes<br />
Fiber colours<br />
1-12: red, green, yellow, blue, white, violet, orange, black, grey, brown, pink, turquoise<br />
13-24: red, green, yellow, blue, white, violet, orange, transparent, grey, brown, pink, turquoise -each with black rings every 50 mm (max.)<br />
Tube colour<br />
red<br />
Laying<br />
usable for fixed laying in ducts or conduits and outdoors<br />
Marking<br />
double-sinus, phone-sign, meter marking, PENGG KABEL, year of manufacturing<br />
Technical Data<br />
tensile strength:<br />
compressive strength:<br />
impact strength:<br />
<strong>to</strong>rsion:<br />
kink, cable:<br />
kink, tube:<br />
min. bending radius:<br />
temperature range:<br />
water penetration:<br />
according <strong>to</strong> IEC 60794-1-E1<br />
according <strong>to</strong> IEC 60794-1-E3 | value: 3000 N/10 cm<br />
according <strong>to</strong> IEC 60794-1-E4 | value: 5 Nm<br />
according <strong>to</strong> IEC 60794-1-E7 | value: 5 cycles ±1 turn<br />
according <strong>to</strong> IEC 60794-1-E10 | value: The cables do not form a kink when a loop is drawn <strong>to</strong>ge<strong>the</strong>r <strong>to</strong> a diameter<br />
of 100 mm.<br />
according <strong>to</strong> IEC 60794-1-E16 | value: The loose tubes do not kink.<br />
according <strong>to</strong> IEC 60794-1-E11 | value: R = 20 x D (cable outer diameter)<br />
according <strong>to</strong> IEC 60794-1-F1<br />
s<strong>to</strong>rage and transport: -40°C up <strong>to</strong> +70°C<br />
laying:<br />
-5°C up <strong>to</strong> +60°C<br />
operation:<br />
-25°C up <strong>to</strong> +70°C<br />
according <strong>to</strong> IEC 60794-1-F5 | value: No water on free end.<br />
OPDISYS ® Fiber <strong>to</strong> <strong>the</strong> Home - Solution • 02/2016 • © by Pengg Kabel GmbH • Technische Änderungen vorbehalten<br />
7