eneral building inspections permit Z-9.1-651 • General building<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> ”One for all“<br />
ADDITONAL APPLICATION OPTIONS<br />
of visible or invisible connections<br />
• For connecting tanner purlins.<br />
• For connecting wall elements in wood frame construction.<br />
• For connecting beam structures.<br />
• For connecting ridge connections.<br />
• For attaching pre-manufactured attaching elements in interior finishing.<br />
• For attaching platforms with covered balconies.<br />
• For attaching balcony railings (posts and handrails).<br />
• Versatile connections for the construction of conservatories, summer<br />
houses, saunas, arbours, exhibition stands, carports.<br />
Installation with shadow gap<br />
ASSEMBLY INFORMATION<br />
• The BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked on the main beam, support or purlin is marked (according to the<br />
installation position of the secondary beam) and bolted together with BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws<br />
under 90°. The centre web (finger) points upward against the attachment direction.<br />
• The installation position of the BiLO ® -<strong>UBt</strong>-connection is measured and marked on the secondary beam.<br />
• Position the <strong>connector</strong> and screw together with BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws below 90°.<br />
• The centre web (finger) points down in the attachment direction.<br />
• Advantage of the 90° bolting compared to the slanted bolting:<br />
The positioned <strong>connector</strong> does not shift.<br />
• It is attached with diameter 6 x 80 mm BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws.<br />
Installation without a shadow gap<br />
(e.g. main-secondary beam)<br />
ASSEMBLY INFORMATION<br />
• BiLO ® -<strong>UBt</strong>-<strong>connector</strong> is marked on the main beam according<br />
to the installation position of the secondary beam and<br />
lowered 8.5 - 9 mm deep.<br />
• Place the BiLO ® -<strong>UBt</strong>-<strong>connector</strong> in the milled-out portion and<br />
bolt with BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws, diameter 6 x 80 mm under 90°.<br />
• The centre web (finger) points upward against the attachment direction.<br />
• The installation position of the BiLO ® -<strong>UBt</strong>-connection is measured<br />
and marked on the secondary beam.<br />
• Position the <strong>connector</strong> and screw together with<br />
BiLO ® -<strong>UBt</strong>-<strong>connector</strong> screws below 90°.<br />
®<br />
BiLO<br />
Z-9.1-651<br />
NRW 02<br />
EFFICIENT TIMBER JOINTS!<br />
Main/secondary beam connection,<br />
main beam is sloped vertically.<br />
Orthogonal connection:<br />
Support crossbar.<br />
<strong>Co</strong>nnecting a tanner‘s purlin with a shadow gap.<br />
Pre-assembled HT – NT connection.<br />
Sinking at the main beam.<br />
<strong>Co</strong>nnection sloping vertically<br />
downward: Support crossbar.<br />
Sinking,<br />
bolting,<br />
attaching,<br />
finished<br />
Ridge connection installed laterally<br />
with shadow gap <strong>connector</strong>.<br />
<strong>Co</strong>nnection sloping vertically upward:<br />
Support crossbar.<br />
00.3