TFT-Display Datenblatt - Hy-Line
TFT-Display Datenblatt - Hy-Line
TFT-Display Datenblatt - Hy-Line
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Ver. 1.0<br />
Product Specification<br />
Table 3. ELECTRICAL CHARACTERISTICS (Continue)<br />
Inverter :<br />
Power Supply Input Voltage<br />
Power Supply Input Voltage Ripple<br />
Power Supply<br />
Input Current<br />
Power Consumption<br />
Life Time<br />
LC370WXN<br />
Notes :<br />
1. Electrical characteristics are determined after the unit has been ‘ON’ and stable for approximately 120<br />
minutes at 25± 2°C. The specified current and power consumption are under the typical supply Input voltage<br />
24Vand VBR (VBR-A : 1.65V & VBR-B :3.3V), it is total power consumption.<br />
The ripple voltage of the power supply input voltage is under 0.5 Vp-p. LPL recommend Input Voltage is<br />
24.0V ± 5%.<br />
2. Electrical characteristics are determined within 30 minutes at 25± 2°C.<br />
The specified currents are under the typical supply Input voltage 24V.<br />
3. Brightness Control.<br />
This VBR-B Voltage control brightness.<br />
VBR-B Voltage<br />
After Aging<br />
Before Aging<br />
Power Supply Input Current (In-Rush)<br />
Input Voltage for<br />
Control System<br />
Signals<br />
Lamp:<br />
Parameter Symbol<br />
Brightness Adjust<br />
On/Off<br />
Brightness Adjust<br />
Function<br />
VBL<br />
IBL_A<br />
IBL_B<br />
Irush<br />
PBL<br />
VBR-A<br />
VBR-B<br />
50,000<br />
VBR-B Voltage<br />
Function<br />
0V<br />
Minimum Duty (20%)<br />
3.3V<br />
Maximum Duty (100%)<br />
.<br />
4. The brightness of the lamp after lighted for 5minutes is defined as 100%.<br />
TS is the time required for the brightness of the center of the lamp to be not less than 95% at typical current.<br />
The screen of LCD module may be partially dark by the time the brightness of lamp is stable after turn on.<br />
5. Specified Values are for a single lamp which is aligned horizontally.<br />
The life time is determined as the time which luminance of the lamp is 50% compared to that of initial value<br />
at the typical lamp current (VBR-A : 1.65V & VBR-B :3.3V), on condition of continuous operating at 25 ± 2°C<br />
6. The duration of rush current is about 10ms.<br />
Min<br />
22.8<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
0.0<br />
0<br />
Values<br />
Typ<br />
24.0<br />
-<br />
5.0<br />
5.5<br />
5.5<br />
6.0<br />
-<br />
120<br />
1.65<br />
-<br />
Max<br />
25.2<br />
0.5<br />
5.5<br />
6.0<br />
6.0<br />
6.5<br />
8<br />
132<br />
3.3<br />
3.3<br />
Unit<br />
Vdc<br />
Vp-p<br />
A<br />
A<br />
A<br />
A<br />
A<br />
W<br />
Vdc<br />
On V on 2.5 - 5.0 Vdc<br />
Off V off -0.3 0.0 0.8 Vdc<br />
HY-LINE Computer Components / www.hy-line.de/computer<br />
V<br />
Hrs<br />
Notes<br />
1<br />
1<br />
VBR-A = 1.65V …<br />
1<br />
VBR-A = 3.3V … 1<br />
VBR-A = 1.65V …<br />
2<br />
V BR-A = 3.3V … 2<br />
VBL = 22.8V<br />
VBR-B = 3.3V<br />
VBR-A = 1.65V<br />
VBR-A = 1.65V …<br />
1<br />
3<br />
4<br />
7 / 34