10.12.2018 Views

Accessory Catalogue 2019/2020

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

158 |<br />

MONITORING ACCESSORIES | INFINITY® MONITORING<br />

INVASIVE BLOOD PRESSURE (IBP)<br />

AND CARDIAC OUTPUT (CO)<br />

Hemodynamic Connectivity<br />

Infinity Acute Care System Infinity Bedside Monitors<br />

Infinity M540<br />

MS23897 2.0 M<br />

MS23898 2.9 M<br />

Hemo<br />

Infinity Gamma X XL<br />

Vista XL<br />

Infinity Delta/XL<br />

Infinity Kappa Infinity Kappa XLT<br />

*PiCCO not supported<br />

7257988 0.3 M<br />

3368425 3.0 M<br />

5195198 5.0 M<br />

Aux/Hemo 2, 3<br />

5591925 3.0 M<br />

5591933 5.0 M<br />

HemoMed<br />

HemoMed<br />

Aux/Hemo 2, 3<br />

or<br />

HemoMed HemoMed<br />

Aux/Hemo 2, 3<br />

Aux/Hemo 2, 3<br />

Hemo<br />

Monitor HemoMed<br />

Monitor<br />

IBP<br />

IBP<br />

Aux/Hemo<br />

HemoMed<br />

Quad Hemo<br />

Dual Hemo Hemo4<br />

Hemo2<br />

PiCCO<br />

PiCCO Gen II<br />

HemoMed<br />

MS20725<br />

MS20783<br />

4315961<br />

4319435<br />

Hemo<br />

MS16734<br />

Kappa XLT does not support PiCCO<br />

MS23133<br />

5588822<br />

Kappa XLT does not support PiCCO<br />

Temp A<br />

Temp B<br />

C.O.<br />

Monitor<br />

Temp A<br />

Temp B<br />

C.O.<br />

IBP<br />

Temp A<br />

Temp B<br />

C.O.<br />

IBP<br />

C.O.<br />

Aux/Hemo<br />

C.O. Aux/Hemo<br />

HemoMed<br />

C.O.<br />

+ + + +<br />

A B C D<br />

A B<br />

A B C D<br />

+ +<br />

+<br />

A B<br />

A B C D<br />

+ +<br />

PiCCO uses 10 pin adapter 3375958 with<br />

transducer adapter cable MS16920<br />

+ + + +<br />

A B C D<br />

PiCCO uses 10 pin adapter MS22532 with<br />

transducer adapter cable MS16920<br />

A B C D<br />

7 Pin<br />

MS22533<br />

10 Pin<br />

MS22532<br />

Abbott-Medex<br />

(Transtar)<br />

MS22535<br />

Baxter-<br />

Edwards<br />

MS22147<br />

Argon/BD<br />

MS22148<br />

Utah<br />

Medical<br />

MS22534<br />

7 Pin<br />

MS23598<br />

10 Pin<br />

3375958<br />

Abbott-Medex<br />

(Transtar)<br />

5196998<br />

Baxter-<br />

Edwards<br />

5196980<br />

Argon/BD<br />

3375941<br />

4329822 1.5 m<br />

5204669 3 m<br />

Single Patient Use<br />

Adult<br />

MP00995 1.6 m<br />

MP00996 3 m<br />

Pediatric<br />

MP00997 1.6 m<br />

MP00998 3 m<br />

Adult<br />

4329889 1.5 m<br />

5204644 3 m<br />

Pediatric<br />

4329848 1.5 m<br />

5204651 3 m<br />

Single Patient Use<br />

Adult<br />

MP00991 1.6 m<br />

MP00992 3 m<br />

Pediatric<br />

MP00993 1.6 m<br />

MP00994 3 m<br />

C.O.<br />

1<br />

2<br />

1<br />

Argon/BD<br />

+ +<br />

Baxter<br />

Edwards<br />

2 2<br />

or<br />

3368458 8419160 8420077 5741975 8539983<br />

C.O.<br />

1<br />

2<br />

+<br />

1<br />

2<br />

MS16916 MS16918 MS16919<br />

Vendor specific adapter cables [A-B-C-D] Vendor specific Hemo Pod adapters [AB-CD]<br />

Temperature<br />

Cardiac Output (C.O.)<br />

PiCCO<br />

10-2016<br />

Not all articles are available worldwide.