Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

2.3 Feed Data<br />

Table 4: LPCCR Feed Distillation<br />

Distillation %<br />

DCS Case<br />

06/25/18<br />

Max.<br />

Charge<br />

08/30/18<br />

Avg.<br />

Charge<br />

04/13/18<br />

Max.<br />

Firing<br />

06/11/18<br />

Avg.<br />

Firing<br />

03/17/18<br />

°F IBP 136 139 136 136 140<br />

°F 10% 157 189 156 158 188<br />

°F 20% 192 198 191 194 197<br />

°F 30% 203 209 200 206 208<br />

°F 40% 215 219 209 217 218<br />

°F 50% 230 240 221 231 231<br />

°F 60% 252 258 244 252 247<br />

°F 70% 272 280 261 270 260<br />

°F 80% 296 299 284 290 281<br />

°F 90% 335 339 319 324 308<br />

FBP 384 408 366 371 358<br />

Table 5 : LPCCR Feed Composition: - Naphtha<br />

Compositi<br />

on, %<br />

DCS Case<br />

06/25/18<br />

Max<br />

Charge<br />

08/30/18<br />

Average<br />

Charge<br />

04/13/18<br />

Maximum<br />

Firing<br />

06/11/18<br />

Average<br />

Firing<br />

03/17/18<br />

C6 P 6.03 4.30 8.04 6.15 7.02<br />

C7 P 8.60 8.42 7.95 8.63 9.05<br />

C8 P 6.54 6.40 5.86 6.92 6.92<br />

Furnace Improvements<br />

Low Cost Solutions for Fired Heaters 18