14.03.2019 Views

FIS-483 Engineering Study Report R1.03.11.19

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Marathon Petroleum Company, Catlettsburg Refinery, KY<br />

Capacity Improvement <strong>Study</strong> of LPCCR Platformer Heater (1-44-B-1/2/3/4)<br />

Figure 45: Inter Heater 2 Firing Rate (Provided by Client) ........................................ 76<br />

Figure 46: Inter Heater 2 Firing Rate (from Fuel Flow Rate) .................................... 77<br />

Figure 47: Inter Heater 2 Firing Rate Comparison ...................................................... 77<br />

Figure 48: Charge Rate × ∆T Vs Firing Rate of Inter Heater 2 ................................. 78<br />

Figure 49: Inter Heater 2 Bridge Wall Temperature Vs Firing Rate (Provided by<br />

Client) ................................................................................................................................. 78<br />

Figure 50: Inter Heater 3 Feed Inlet Temperature ...................................................... 82<br />

Figure 51: Inter Heater 3 Feed Outlet Temperature ................................................... 82<br />

Figure 52: Inter Heater 3 Temperature Rise ................................................................ 83<br />

Figure 53: Charge Rate × ∆T of Inter Heater 3 ........................................................... 83<br />

Figure 54: Inter Heater 3 Tube Metal Temperature .................................................... 84<br />

Figure 55: Flue Gas Temperature Leaving Inter Heater 3 ........................................ 84<br />

Figure 56: Excess O2 at Inter Heater 3 Exit ................................................................. 85<br />

Figure 57: Inter Heater 3 Fuel Gas Flow Rate ............................................................ 85<br />

Figure 58: Inter Heater 3 Fuel Gas Pressure .............................................................. 86<br />

Figure 59: Inter Heater 3 Firing Rate (Provided by Client) ........................................ 86<br />

Figure 60: Inter Heater 3 Firing Rate (from Fuel Flow Rate) .................................... 87<br />

Figure 61: Inter Heater 3 Firing Rate Comparison ...................................................... 87<br />

Figure 62: Charge Rate × ∆T Vs Firing Rate of Inter Heater 3 ................................. 88<br />

Figure 63: Inter Heater 3 Bridge Wall Temperature Vs Firing Rate (Provided by<br />

Client) ................................................................................................................................. 88<br />

Figure 64: Steam Generation Coil Circulation (MGPM) ............................................. 92<br />

Figure 65: Steam generation Coil Circulation (Mlb/hr) ............................................... 92<br />

Figure 66: Flow Rate of Steam Generated .................................................................. 93<br />

Figure 67: Boiler Feed Water Flow Rate (GPM) ......................................................... 93<br />

Furnace Improvements<br />

Low Cost Solutions for Fired Heaters 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!