ICEROSS ® TRANSFEMORAL LINERS BY ÖSSUR<br />

ÖSSUR LINERS<br />

AND SOCKETS<br />

The transfemoral residual limb offers slightly different challenges to the prosthetist than the transtibial residual limb in terms of achieving<br />

optimal results from a prosthetic fitting. In recognizing these challenges, Ö<strong>ssur</strong> was the first to design and introduce a specific Iceross<br />

Transfemoral liner to offer comfort, protection and optimal suspension of the transfemoral prosthesis.<br />

1. Size<br />

2. Limb length<br />

3. Profile<br />

4. Use of fitting aids<br />

1. SIZE<br />

With the tissue of the residual limb hanging down, measure 4cm proximal to the distal end of the limb<br />

and mark this point on the skin. Measure the circumference of the limb at this point with medium<br />

tension on the tape measure.<br />

Iceross size 25cm<br />

User measurement 26cm<br />

The measurement taken corresponds to the size of Iceross to be used. Select the liner size matching your measurement or, if between sizes,<br />

select the next size below. Do not select a size larger than your measurement or more than one size below it. E.g. if the circumference of the<br />

limb measures 26cm, select Iceross size 25.<br />

NOTE - ICEROSS LOCKING LINERS:<br />

The incorporated size-specific umbrella works in conjunction with the matrix. Optimal function of both the umbrella and matrix is dependent<br />

on correct size selection of the Iceross liner. Incorrect sizing may cause discomfort to the user, perspiration and reduced control of the<br />

prosthesis.<br />

NOTE - ICEROSS SEAL-IN LINERS:<br />

For Iceross Seal-In liners, it is essential that the Hypobaric Sealing Membrane (HSM) sits correctly against the liner around its full<br />

circumference. Once you have selected the liner according to our instructions, assess the membrane according to the pictures below, visually<br />

and manually. Picture 3 is the optimal situation. In some cases, the next size down may need to be selected to achieve this fitting. It is unique<br />

to the Iceross Seal-In liner and should not be applied to any other Iceross models including the Iceross Seal-In X5.<br />

1. LINER IS TOO SMALL 2. LINER IS TOO BIG<br />

3. LINER FITS CORRECTLY<br />

The sizing recommendations are intended as a guide. There may be occasions when alternative sizes need to be selected.<br />