• Data rate: 57600 bps<br />

• 1 start bit<br />

• 8 data bits<br />

• No parity<br />

• 1 stop bit<br />

5<br />

9<br />

Figure 5 Pin Definitions for Female 9 Pin Sub-D Connector (as seen by looking at<br />

front panel)<br />

Pin # Signal Name Direction Signal Description<br />

1 NC<br />

2 TXD Out Transmit Data (from <strong>IDU</strong>)<br />

3 RXD In Receive Data (to <strong>IDU</strong>)<br />

4 NC<br />

5 GND N/A Ground<br />

6 NC<br />

7 NC<br />

8 NC<br />

9 NC<br />

1.2.6. DC Power<br />

Table 3 CLI Connector Pinout<br />

6<br />

DC Power is provided via a three terminal connector, as indicated in Figure 6.<br />

A switch internal to the <strong>IDU</strong> must be set to the desired polarity.<br />

For positive voltage operation:<br />

• Internal power switch must be set for “+24V” operation<br />

• Connect positive terminal of external supply to “+V” terminal of<br />

ALXXF<br />

• Connect negative terminal of external supply to “-V” terminal of<br />

ALXXF.<br />

• Connect negative terminal of external supply to “GND” terminal of<br />

ALXXF.<br />

1<br />

ALCOMA Proprietary Page 10 of 16