1.2.3. Ethernet Management Ports<br />

The two Ethernet management ports (Mgmt-1 and Mgmt-2) provide<br />

10/100BaseT interfaces to the <strong>IDU</strong>’with standard RJ-45 pinouts. These ports<br />

allow management access to the <strong>IDU</strong>’s internal CPU. An internal Ethernet<br />

switch also provides layer 2 switching functions between these two ports and<br />

the far side terminal. The Ethernet PHYs provide MDI/MDI-X cross-connect<br />

with auto-detect, so both straight-thru and cross cables are accommodated to<br />

any other 10/100 Base-T interface.<br />

Note that Ethernet-based management is not yet enabled on the<br />

prototypes. These functions will be enabled with a future firmware update.<br />

1.2.4. Overhead/Hot Standby Interface<br />

The Overhead and Hot Standby signals are provided over a DB-26 interface<br />

with connector pinouts and signal assignments as defined in Figure 4 and<br />

Table 2 below.<br />

9<br />

26<br />

Figure 4 Pinout for High-density DB-26 Connector (as seen looking at front panel)<br />

1<br />

19<br />

ALCOMA Proprietary Page 8 of 16