<strong>Uniflow</strong>-4 Benefits<br />
<strong>Uniflow</strong>-4 is a power supply for pulsed heat, Hot Bar<br />
Reflow Soldering, Heat-Seal bonding, ACF Laminating,<br />
ACF Final Bonding and Heat Staking:<br />
• Closed loop temperature and time control<br />
• Stores 15 heating profiles<br />
• Numeric and graphical data output to PC<br />
• Process alarms and counters<br />
• Remote programming via RS-232/485<br />
• Peak and average temperature limits<br />
• Optional interrupt function to abort heating cycle<br />
• 2 thermocouples for process control and auxilary<br />
monitoring<br />
• Comprehensive and informative user interface with:<br />
- Graphic and numeric process data<br />
- Status and Alarm messages<br />
- Heat profile settings and envelope limits<br />
- Temperature error indicators<br />
- User scalable time axis<br />
- Real time temperature plot<br />
<strong>Uniflow</strong>-4 Applications<br />
Utilising pulsed heat technology, the <strong>Uniflow</strong>-4 power supply provides targeted heating<br />
and precision temperature control for a variety of joining applications:<br />
• Flexible circuits<br />
• Ribbon cables<br />
• Wires<br />
• Flex-glass connections<br />
• Coaxial cables<br />
• SMT components<br />
• Single or dual sided edge connectors<br />
• Thermo compression bonding of gold ribbon<br />
• Heat Staking (plastic moulding)<br />
Medical<br />
Automotive<br />
Consumer Electronics<br />
<strong>Uniflow</strong>-4<br />
Pulsed Heat Control System<br />
Aerospace<br />
<strong>Miyachi</strong> <strong>Europe</strong> Corporation 1/2 Technical Data Sheet <strong>Uniflow</strong>-4 Power Supply
<strong>Uniflow</strong>-4 Application Solutions<br />
The <strong>Uniflow</strong>-4 is used in the production of cellular phones, pagers,<br />
handsets, LCD monitors, LCD TV’s, laptops, palmtops, disk drives,<br />
industrial instrumentation, dashboards, satellite navigation systems,<br />
on-board computers, home audio and video, calculators, watches,<br />
cameras, electronic games, CD players, cockpit instrumentation and<br />
displays, medical devices, and many more�<br />
<strong>Uniflow</strong>-4 Technical Specifications<br />
Temperature Profile Specifications<br />
Temperature range<br />
Idle<br />
Baseheat<br />
Preheat<br />
Time period (in 0.1 sec increments)<br />
Base Heat<br />
Rise to Preheat Time<br />
Preheat<br />
Temperature control<br />
Accuracy<br />
Repeatability<br />
25 to 300 °C<br />
25 to 300 °C<br />
60 to 500 °C<br />
0 to 99.9 seconds<br />
0 to 9.9 seconds<br />
0 to 99.9 seconds or<br />
continuous<br />
Heat<br />
Heat Extended Range<br />
Postheat<br />
Rise to Heat Time<br />
Heat<br />
Postheat<br />
± 2% of reading or ± 6 °C whichever is greater<br />
± 1% of reading<br />
60 to 600 °C<br />
60 to 999 °C<br />
25 to 999 °C<br />
0 to 9.9 seconds<br />
0.1 to 99.9 seconds<br />
0 to 99.9 seconds<br />
Thermocouple input Type E, J, or K (dual input)<br />
Heating rate control Three integrated user-set parameters optimize temperature<br />
profile<br />
Interrupt function (optional) Stop heating cycle at reach of force or displacement limit through<br />
external device<br />
Programmable heat profiles Fifteen (15) non-volatile memory<br />
Switched Input Electrical Specifications<br />
Operator initiation 1 or 2 level footswitch<br />
Dedicated relays 24 VAC/0.3A<br />
Head cool<br />
Solder cool<br />
Programmable relays<br />
Contact rating<br />
ON/OFF for cooling thermode holder<br />
ON@COOL, OFF@PREHEAT<br />
7 each, electromechanical (24VAC or +24 DC)<br />
24 VAC/24DC, 0.3A<br />
Communication ports RS-232, RS-485<br />
Programmable relay functions Reflow, preheat, baseheat, idle on, alarm, out of limits, clean<br />
thermode, replace thermode, end reflow, heat on, head valve<br />
active, system ready<br />
Physical/Environmental Specifications<br />
Dimensions HxWxD (mm) 319 x 254 x 466<br />
Operating temperatures 40 °C<br />
Weight (kg) 4kVA model - 27.2<br />
2kVA model - 21.8<br />
Relative humidity, maximum 93% @ 40 °C<br />
Local Representative<br />
All data, images and text described and illustrated in this technical data sheet are subject to change. <strong>Miyachi</strong> <strong>Europe</strong> reserves the right to modify the<br />
specifications, the design and the illustrations at any time. All rights reserved – July 2012.<br />
<strong>Miyachi</strong> <strong>Europe</strong> Corporation 2/2<br />
Technical Data Sheet <strong>Uniflow</strong>-4 Power Supply