Fiber Optic Cable Distances for 10 Gb/s Networks<br />
10 gigabit (10,000 Mb/s) backbones with horizontal links of 1 Gb/s are becoming<br />
common. While these speeds were possible before with single-mode fiber, the high electronics<br />
costs were a limiting factor. However, new and economical 850 nm Vertical Cavity Surface<br />
Emitting Lasers (VCSELs) make operating these very high speed networks possible over highbandwidth<br />
laser-optimized 50 µm multimode fibers.<br />
Outlet<br />
90 m<br />
Outlet<br />
300 meters in<br />
collapsed<br />
backbones<br />
Equipment room<br />
(intermediate<br />
crossconnect)<br />
The 90 meters of 1 Gb/s horizontal cabling still can be either twisted pair or multimode fiber.<br />
Backbone connections of 300 meters must use laser-optimized 50 µm fiber or single-mode<br />
fiber. While standards limit campus transmission distances to 300 meters, links in the 500 -<br />
600 meter range are possible with high bandwidth 50 µm fiber (at these operating distances,<br />
pay special attention to loss budgets). Distances beyond that require the use of single-mode<br />
transmission systems.<br />
Fiber<br />
Description<br />
Bandwidth (MHz•km)<br />
850/1300 nm<br />
50 µm OM4 4700*/500 550 m<br />
50 µm OM3 2000*/500 300 m<br />
50 µm OM2+ 950*/500 150 m<br />
50 µm OM2 500/500 82 m<br />
10 Gb/s Range<br />
with 850 nm VCSEL<br />
62.5 µm OM1 200 /500 33 m - very limited distance<br />
8.3 µm single-mode NA 2 km and up**<br />
* Effective Modal Bandwidth (EMB)<br />
**using 1310 & 1550 nm lasers<br />
Telecommunications Room<br />
(horizontal crossconnect)<br />
X meters between<br />
crossconnects<br />
(distributed<br />
backbones)<br />
300 meters 50 µm OM3 multimode<br />
3000+ meters single-mode<br />
total cabled distance (X+Y) between<br />
active equipment shall not exceed<br />
300 meters for multimode fiber<br />
Y meters 50 µm OM3 multimode<br />
2500+ meters single-mode<br />
Central<br />
equipment<br />
room<br />
(main crossconnect)<br />
to Local<br />
Access<br />
www.commscope.com 29