SECTION 1—IN GENERAL SECTION 2—INSTALLATION OF COMPONENTS<br />

<strong>Adjustable</strong> <strong>Stroke</strong> <strong>Detect</strong>-A-<strong>Finger</strong> ® <strong>Drop</strong>-<strong>Probe</strong> <strong>Device</strong> <strong>Adjustable</strong> <strong>Stroke</strong> <strong>Detect</strong>-A-<strong>Finger</strong> ® <strong>Drop</strong>-<strong>Probe</strong> <strong>Device</strong><br />

Control Box<br />

The DAF-100 system control box consists of an FTL-071 complete PC board<br />

which includes safety relays and pin-type plug-in terminals housed in an 8”<br />

x 6” NEMA enclosure. The control box should be mounted in a convenient<br />

location and should be mounted within two feet of the mini filter-regulator<br />

assembly. The area around the control box should be kept clear and be<br />

easily accessible <strong>for</strong> wiring and maintenance.<br />

Outside View of DAF-100 Control Box<br />

All electrical power and air supply to the machine must be<br />

off be<strong>for</strong>e mounting, wiring, or servicing the control box.<br />

Air Tube<br />

Bulkheads<br />

Inside View of DAF-100 Control Box<br />

4-Pole Safety<br />

Relay<br />

FTF-071<br />

PC Board (Complete)<br />

24-V DC Power<br />

Supply<br />

6-Pole<br />

Safety Relay<br />

Fuse<br />

3 Pole Power Plug<br />

(100-240V AC)<br />

Input/Output<br />

Plug<br />

Rock<strong>for</strong>d Systems, LLC<br />

8 Call: 1-800-922-7533