licence certificate - OMRON
licence certificate - OMRON
licence certificate - OMRON
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
TÜV Rheinland Industrie Service GmbH<br />
LICENCE CERTIFICATE No. 968/EZ 400.00/09<br />
for TÜV Rheinland Test Mark<br />
Licence Holder: <strong>OMRON</strong> SCIENTIFIC TECHNOLOGIES, INC.<br />
6550 Dumbarton Circle<br />
Fremont CA 94555-3605<br />
United States of America<br />
Manufacturer: H. Zander GmbH & Co. KG<br />
Am Gut Wolf 15<br />
52070 Aachen<br />
Germany<br />
Date of Application: File Ref.: Date of Issue:<br />
2009-11-18 968/EZ 400.00/09 2009-12-08<br />
Description: Contact extension unit which is used in combination with a<br />
SR10xA series basis unit of <strong>OMRON</strong> for time delayed safety<br />
related emergency stop applications (stop category 1 acc. to<br />
EN 60204-1).<br />
Product tested: Contact extension unit SR106ED0x<br />
Type designation: SR106ED01 / SR106ED02 / SR106ED03<br />
Supply voltage: SR106ED03 - AC 230 V (50 - 60 Hz)<br />
SR106ED02 - AC 115 V (50 - 60 Hz)<br />
SR106ED01 - AC/DC 24 V (AC: 50 - 60 Hz)<br />
Max. switched current: 6 A (250 V, resistive load) / 4 A (230 V, AC-15)<br />
1,25 A (24 V, resistive load) / 2 A (24 V, DC-13)<br />
Kontakte: 3 forcibly guided and redundant safety contacts<br />
1 diagnostic contact<br />
Annual fee:<br />
The test sample - will be kept by TÜV Rheinland Industrie Service GmbH<br />
- will be kept by the <strong>licence</strong> holder for the disposal of<br />
TÜV Rheinland Industrie Service GmbH<br />
Special Remarks: Report-No.: 968/EZ 400.00/09 dated 2009-12-08 and Certificate-No.:<br />
968/EZ 400.00/09 dated 2009-12-08.<br />
This <strong>licence</strong> <strong>certificate</strong> is valid until 2014-12-08.<br />
Test Mark:<br />
2009-12-08<br />
Annual<br />
Fee-<br />
Units<br />
The Licence for the using of the TÜV Rheinland Test Mark is only valid<br />
for the <strong>licence</strong> holder and can only be transferred from TÜV Rheinland<br />
Industrie Service GmbH to third persons.<br />
The right for the using of the Test Mark is restricted to such products<br />
which are described and are examined by TÜV Rheinland Industrie<br />
Service GmbH appropriately.<br />
This Licence <strong>certificate</strong> has to be given back to TÜV Rheinland Industrie<br />
Service GmbH if it is being declared as invalid.<br />
Furthermore all clauses of the Test Mark Regulations apply.<br />
Date Company stamp Dipl.-Ing. Stephan Häb<br />