23.12.2012 Views

licence certificate - OMRON

licence certificate - OMRON

licence certificate - OMRON

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TÜV Rheinland Industrie Service GmbH<br />

LICENCE CERTIFICATE No. 968/EZ 400.00/09<br />

for TÜV Rheinland Test Mark<br />

Licence Holder: <strong>OMRON</strong> SCIENTIFIC TECHNOLOGIES, INC.<br />

6550 Dumbarton Circle<br />

Fremont CA 94555-3605<br />

United States of America<br />

Manufacturer: H. Zander GmbH & Co. KG<br />

Am Gut Wolf 15<br />

52070 Aachen<br />

Germany<br />

Date of Application: File Ref.: Date of Issue:<br />

2009-11-18 968/EZ 400.00/09 2009-12-08<br />

Description: Contact extension unit which is used in combination with a<br />

SR10xA series basis unit of <strong>OMRON</strong> for time delayed safety<br />

related emergency stop applications (stop category 1 acc. to<br />

EN 60204-1).<br />

Product tested: Contact extension unit SR106ED0x<br />

Type designation: SR106ED01 / SR106ED02 / SR106ED03<br />

Supply voltage: SR106ED03 - AC 230 V (50 - 60 Hz)<br />

SR106ED02 - AC 115 V (50 - 60 Hz)<br />

SR106ED01 - AC/DC 24 V (AC: 50 - 60 Hz)<br />

Max. switched current: 6 A (250 V, resistive load) / 4 A (230 V, AC-15)<br />

1,25 A (24 V, resistive load) / 2 A (24 V, DC-13)<br />

Kontakte: 3 forcibly guided and redundant safety contacts<br />

1 diagnostic contact<br />

Annual fee:<br />

The test sample - will be kept by TÜV Rheinland Industrie Service GmbH<br />

- will be kept by the <strong>licence</strong> holder for the disposal of<br />

TÜV Rheinland Industrie Service GmbH<br />

Special Remarks: Report-No.: 968/EZ 400.00/09 dated 2009-12-08 and Certificate-No.:<br />

968/EZ 400.00/09 dated 2009-12-08.<br />

This <strong>licence</strong> <strong>certificate</strong> is valid until 2014-12-08.<br />

Test Mark:<br />

2009-12-08<br />

Annual<br />

Fee-<br />

Units<br />

The Licence for the using of the TÜV Rheinland Test Mark is only valid<br />

for the <strong>licence</strong> holder and can only be transferred from TÜV Rheinland<br />

Industrie Service GmbH to third persons.<br />

The right for the using of the Test Mark is restricted to such products<br />

which are described and are examined by TÜV Rheinland Industrie<br />

Service GmbH appropriately.<br />

This Licence <strong>certificate</strong> has to be given back to TÜV Rheinland Industrie<br />

Service GmbH if it is being declared as invalid.<br />

Furthermore all clauses of the Test Mark Regulations apply.<br />

Date Company stamp Dipl.-Ing. Stephan Häb<br />

2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!