Notes:<br />

1. This normally shows the number of markers used in the camera position calculation, but<br />

by using toggle switch S2 the display can be switched, in sequence, to the number of<br />

markers identified (i.e. which target bar-codes have been read), the number of markers<br />

detected by the hardware and the DSP status value. If the DSP status is positive it<br />

indicates the number of iterations required in the camera position calculation; if<br />

negative it indicates an error code as follows:<br />

• -1 = too few valid markers<br />

• -2 = iteration failed to converge<br />

• -3 = A DSP reset occurred<br />

• -4 = Internal DSP error<br />

2. This can be scrolled to show the nine bytes of camera data (hexadecimal) as ZH ZM ZL<br />

FH FM FL AU ID GP, where:<br />

• ZH ZM ZL is the current zoom value (24 bits)<br />

• FH FM FL is the current focus value (24 bits)<br />

• AU is the auxiliary data (for example, diagnostic)<br />

• ID is the camera’s identification number<br />

• GP is 8-bits of general-purpose user input<br />

3. This selects and indicates which marker's information is displayed in positions B to F.<br />