Programming and calibrating<br />
7.3.1.2 Calibrating<br />
When calibrating the function "Time dosing", feed is conveyed for 10 seconds. The<br />
conveyed amount is measured by the user and entered in the control.<br />
INFO<br />
INFO<br />
To do so, carry out the following steps:<br />
1. Use + /<br />
2. Press<br />
appears:<br />
SET<br />
–<br />
to select the "Time dosing" function:<br />
(>3 sec) long until the following display (example)<br />
3. Actuate the pump nozzle over a collecting tray until the feed pump stops<br />
automatically. Hold the pump nozzle at the same height as when dosing later on to<br />
achieve the greatest possible precision.<br />
4. Measure the conveyed feed amount.<br />
Info<br />
You can measure the feed amount alternatively in kg or in litres. The chosen unit (kg or<br />
litre) must then be used when entering the required volumetric delivery.<br />
5. Briefly press SET<br />
6. Use + /<br />
7. Press<br />
SET<br />
–<br />
to enter the measured feed amount (e.g. 6.2 l):<br />
briefly to exit the calibrating menu.<br />
Info<br />
The precision of the time-controlled dosing depends on several factors, e.g.:<br />
• Charge condition of the battery<br />
• Fill level of feed container<br />
• Height of pump nozzle<br />
• Ambient temperature<br />
An even greater precision is achieved with the (optionally available) "Sensor dosing"<br />
function.<br />
34<br />
Time dosing<br />
004.0 1. 02.0<br />
Time calibration<br />
10 sek 05,000<br />
Time calibration<br />
> 06,200